PEAK Boilers — ENERGY STAR Certified Models
Across ENERGY STAR boilers filings, PEAK accounts for 1 canonical model (1 AHRI matches) ranging from 95.0% AFUE up to 95.0% AFUE (Residential capacities). PEAK Boilers — ENERGY STAR Certified Models benchmarks residential systems using Certified Models set at 1 and Rating Span set at 95.0% AFUE - 95.0% AFUE. Values trace to primary federal, state, or OEM filings supporting PEAK Boilers — ENERGY STAR Certified Models across single-family housing.
- Certified Models
- 1
- Rating Span
- 95.0% AFUE - 95.0% AFUE
- Capacity Range
- Residential capacities
- AHRI Combinations
- 1
- Cold Climate Units
- 0
- Category Median
- 95.0% AFUE
How does PEAK's boilers portfolio cover capacity, refrigerants, and safety?
PEAK covers Residential capacities in boilers across 1 canonical model and 1 AHRI combination, with 0 Cold Climate certified model and Gas / Propane combustion. Ratings span 95.0% AFUE up to 95.0% AFUE (category median 95.0% AFUE, certified through 2021-11-08). CPSC records show 0 residential HVAC recall notices matching PEAK; check exact AHRI matched pairings on individual model sheets.
Which verified records belong in PEAK Boilers — ENERGY STAR Certified Models?
Compare all 1 verified entry below. Click any column header to sort numerically or alphabetically, then select any row for full benchmark citations.
| PEAK40 | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
Which top PEAK boilers anchor this lineup?
Select any of the 1 verified listings below to open detailed specifications, safety boundaries, and source links.
PEAK40
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on PEAK Boilers, review 3 important real-world limits and verify local licensing and permit rules directly.
- Cohort spread across PEAK: 95.0% AFUE entry units differ substantially from flagship PEAK40 (95.0% AFUE).
- Verify indoor coil AHRI pairing on PD ID 2358000 and 2358000 before pulling state mechanical permits.
- Equipment catalog metrics exclude ductwork upgrades, A2L leak sensors where applicable, and municipal inspection fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Best fit for PEAK | Homes matched to Residential capacities seeking Gas / Propane combustion compliance and verified ENERGY STAR documentation. |
| Skip or verify further if | Existing ductwork pushes total static pressure above 0.50 in. w.c. or 3-phase commercial wiring is present. |
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
Which PEAK boilers model reaches the highest 95.0% AFUE rating?
PEAK40 tops PEAK's 1 ENERGY STAR boilers model at 95.0% AFUE across 1 AHRI matches (PD ID 2358000).
How broad is PEAK's boilers efficiency and BTU range?
PEAK spans 95.0% AFUE (PEAK40) up to 95.0% AFUE (PEAK40) across Residential capacities, compared with the 95.0% AFUE category median.
How many AHRI combinations support PEAK boilers?
Current ENERGY STAR datasets document 1 verified indoor-outdoor AHRI combination distributed across 1 canonical PEAK model.
What refrigerants or fuels power PEAK boilers?
PEAK boilers listings record Gas / Propane combustion, with 0 Cold Climate certified model inside the boilers cohort.
Where are PEAK boilers compliant under 2026 federal rules?
Models meeting 13.4 SEER2 qualify in the North; 14.3 SEER2 (plus 11.7 EER2 or 9.8 at 15.2+ SEER2) is needed for Southwest split cooling, while split heat pumps require 14.3 SEER2 / 7.5 HSPF2 nationwide.
Are any CPSC safety recalls linked to PEAK residential HVAC products?
ThermalSpec counts 0 residential HVAC CPSC filings referencing PEAK; verify model serial prefixes at /recalls/ before installation or service.
Do PEAK boilers receive federal Section 25C credits in 2026?
No — IRS Section 25C credits terminated December 31, 2025 ($0 federal tax credit for PEAK in 2026). Check state HOMES/HEAR and local utility ENERGY STAR rebates using PD ID 2358000.
How should homeowners select among PEAK's 1 boilers model?
Match PEAK model capacity (Residential capacities) using an ACCA Manual J room-by-room heat load and <= 0.50 in. w.c. static pressure check rather than old unit tonnage.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Boilers Dataset (6rww-hpns) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)