New Yorker GHE180HBII — Residential Boiler Specifications
New Yorker GHE180HBII (Residential Boiler, PD ID 2386183) holds 1 ENERGY STAR certified SKU rated at 95.0% AFUE — #53 of 663 (402 tied at median), Equal to 95.0% AFUE category median. Condensing ENERGY STAR residential boiler (95.0% AFUE; exceeds 84% federal gas boiler floor). New Yorker GHE180HBII — Residential Boiler Specifications benchmarks residential systems using Thermal Efficiency set at 95.0% AFUE and Cohort Rank set at #53/663.
- Thermal Efficiency
- 95.0% AFUE
- Cohort Rank
- #53/663
- Verified Combos
- 1 SKU
- Sample PD ID
- 2386183
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 87.0 - 88.1% AFUE | 148 | Peer range |
| 88.1 - 89.2% AFUE | 0 | Peer range |
| 89.2 - 90.3% AFUE | 22 | Peer range |
| 90.3 - 91.4% AFUE | 13 | Peer range |
| 91.4 - 92.6% AFUE | 3 | Peer range |
| 92.6 - 93.7% AFUE | 4 | Peer range |
| 93.7 - 94.8% AFUE | 19 | Peer range |
| 94.8 - 95.9% AFUE | 402 | This series |
| 95.9 - 97.0% AFUE | 52 | Peer range |
How does New Yorker GHE180HBII rank across federal compliance and ENERGY STAR cohorts?
New Yorker GHE180HBII ranks #53 of 663 (tied with 401 others at 95.0% AFUE, more efficient than 31.5% of certified series) for Max AFUE (Equal to 95.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 95.0% AFUE (+15.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2023-07-26.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max AFUE) | #53 of 663 (402 tied at median) | Equal to 95.0% AFUE category median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal Residential Boiler Minimum | PASS | Rated 95.0% AFUE vs 84% federal gas hot-water boiler baseline |
| Condensing Hydronic Design | CONDENSING | Extracts latent flue heat below 140F return water temp |
How much annual energy and operating cost does New Yorker GHE180HBII require?
Modeled utility figures for New Yorker GHE180HBII (New Yorker) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max AFUE ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Annual Natural Gas Consumption (50 MMBtu) | 526.3 therms/yr | 6,158 lb CO2/yr (11.7 lb/therm) |
| Estimated Annual Fuel Cost (US Median) | $763/yr | State range: $389 (ID) to $2,658 (HI) |
| Fuel Saved vs 80% AFUE Baseline | 98.7 therms/yr | $143/yr saved |
Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.
Which AHRI certified SKU combinations belong to New Yorker GHE180HBII?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for New Yorker GHE180HBII (PD ID 2386183).
| GHE180HBII | Matched AHRI Coil | — | / 95.0% AFUE |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on New Yorker GHE180HBII, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across New Yorker GHE180HBII: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for New Yorker GHE180HBII exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- New Yorker GHE180HBII condensing combustion at 95.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal New Yorker GHE180HBII fit | Single-family replacement needing documented ENERGY STAR PD ID 2386183 with matching indoor air handler. |
| Skip New Yorker GHE180HBII if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable residential boiler models deliver similar efficiency?
Compare New Yorker GHE180HBII against NTI FTVN150 and closely matched residential boiler units sharing similar Max AFUE output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does New Yorker GHE180HBII compare with peer Residential Boiler units?
New Yorker GHE180HBII holds #53 of 663 (402 tied at median) out of 663 verified residential boiler models (Equal to 95.0% AFUE category median), spanning 1 certified SKU up to 95.0% AFUE. Closest same-cohort alternatives include NTI FTVN150.
Where is New Yorker GHE180HBII compliant for 2026 US installation?
New Yorker GHE180HBII: Condensing ENERGY STAR residential boiler (95.0% AFUE; exceeds 84% federal gas boiler floor). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does New Yorker GHE180HBII model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, New Yorker GHE180HBII runs 526.3 therms/yr across standard cooling/heating hours.
What capacity band and airflow does New Yorker GHE180HBII cover?
New Yorker GHE180HBII covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does New Yorker GHE180HBII handle extreme weather or cold snaps?
New Yorker GHE180HBII delivers steady fuel combustion independent of outdoor air temperature.
What refrigerant class and 2026 tax credit rules govern New Yorker GHE180HBII?
New Yorker GHE180HBII specifies sealed combustion compliance (PD ID 2386183); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in New Yorker GHE180HBII reach 95.0% AFUE?
Peak 95.0% AFUE represents the top tested AHRI pairing for New Yorker GHE180HBII (PD ID 2386183); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to New Yorker GHE180HBII?
New Yorker GHE180HBII requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include NTI FTVN150.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Boilers Dataset (6rww-hpns) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.