Skip to main content
HTP | Boilers

HTP Boilers — ENERGY STAR Certified Models

HTP certifies 15 boilers models across 15 AHRI combinations, led by EFTU-85WBN at 96.0% AFUE against the 95.0% AFUE category median across Residential capacities. HTP Boilers — ENERGY STAR Certified Models benchmarks residential systems using Certified Models set at 15 and Rating Span set at 95.0% AFUE - 96.0% AFUE. Values trace to primary federal, state, or OEM filings supporting HTP Boilers — ENERGY STAR Certified Models across single-family housing.

Certified Models
15
Rating Span
95.0% AFUE - 96.0% AFUE
Capacity Range
Residential capacities
AHRI Combinations
15
Cold Climate Units
0
Category Median
95.0% AFUE
Residential air handler cabinet with galvanized ductwork and brazed copper piping
HTP Boilers — ENERGY STAR Certified Models editorial reference. ThermalSpec Editorial Photography

How does HTP's boilers portfolio cover capacity, refrigerants, and safety?

HTP covers Residential capacities in boilers across 15 canonical models and 15 AHRI combinations, with 0 Cold Climate certified models and Gas / Propane combustion. Ratings span 95.0% AFUE up to 96.0% AFUE (category median 95.0% AFUE, certified through 2021-11-09). CPSC records show 0 residential HVAC recall notices matching HTP; check exact AHRI matched pairings on individual model sheets.

Showing 15 entries

Which verified records belong in HTP Boilers — ENERGY STAR Certified Models?

Compare all 15 verified entries below. Click any column header to sort numerically or alphabetically, then select any row for full benchmark citations.

All 15 ENERGY STAR HTP Boilers Models
HTP EFTU-85WBN 96.0% AFUE Condensing Natural Gas, Propane Gas 1
HTP ELU-85WBN 96.0% AFUE Condensing Natural Gas, Propane Gas 1
HTP EFTU-110WBN 95.0% AFUE Condensing Natural Gas, Propane Gas 1
HTP EFTU-110WCN 95.0% AFUE Condensing Natural Gas, Propane Gas 1
HTP EFTU-150WBN 95.0% AFUE Condensing Natural Gas, Propane Gas 1
HTP EFTU-150WCN 95.0% AFUE Condensing Natural Gas, Propane Gas 1
HTP EFTU-199WBN 95.0% AFUE Condensing Natural Gas, Propane Gas 1
HTP EFTU-199WCN 95.0% AFUE Condensing Natural Gas, Propane Gas 1
HTP EFW-285WBN 95.0% AFUE Condensing Natural Gas, Propane Gas 1
HTP ELU-120WBN 95.0% AFUE Condensing Natural Gas, Propane Gas 1
HTP ELU-120WCN 95.0% AFUE Condensing Natural Gas, Propane Gas 1
HTP ELU-150WBN 95.0% AFUE Condensing Natural Gas, Propane Gas 1
HTP ELU-150WCN 95.0% AFUE Condensing Natural Gas, Propane Gas 1
HTP ELU-199WBN 95.0% AFUE Condensing Natural Gas, Propane Gas 1
HTP ELU-199WCN 95.0% AFUE Condensing Natural Gas, Propane Gas 1

Which top HTP boilers anchor this lineup?

Select any of the 4 verified listings below to open detailed specifications, safety boundaries, and source links.

HTP96.0% AFUE

HTP EFTU-85WBN

Condensing | Natural Gas, Propane Gas | 1 SKU

HTP96.0% AFUE

HTP ELU-85WBN

Condensing | Natural Gas, Propane Gas | 1 SKU

HTP95.0% AFUE

HTP EFTU-110WBN

Condensing | Natural Gas, Propane Gas | 1 SKU

HTP95.0% AFUE

HTP EFTU-110WCN

Condensing | Natural Gas, Propane Gas | 1 SKU

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on HTP Boilers, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Cohort spread across HTP: 95.0% AFUE entry units differ substantially from flagship EFTU-85WBN (96.0% AFUE).
  • Verify indoor coil AHRI pairing on PD ID 2364742 and 2364733 before pulling state mechanical permits.
  • Equipment catalog metrics exclude ductwork upgrades, A2L leak sensors where applicable, and municipal inspection fees.
Homeowner ScenarioRecommended Verification Path
Best fit for HTPHomes matched to Residential capacities seeking Gas / Propane combustion compliance and verified ENERGY STAR documentation.
Skip or verify further ifExisting ductwork pushes total static pressure above 0.50 in. w.c. or 3-phase commercial wiring is present.

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

HTP Peak

Which HTP boilers model reaches the highest 96.0% AFUE rating?

EFTU-85WBN tops HTP's 15 ENERGY STAR boilers models at 96.0% AFUE across 1 AHRI matches (PD ID 2364742).

Lineup Span

How broad is HTP's boilers efficiency and BTU range?

HTP spans 95.0% AFUE (ELU-199WCN) up to 96.0% AFUE (EFTU-85WBN) across Residential capacities, compared with the 95.0% AFUE category median.

AHRI Pairs

How many AHRI combinations support HTP boilers?

Current ENERGY STAR datasets document 15 verified indoor-outdoor AHRI combinations distributed across 15 canonical HTP models.

Cold / Fuel

What refrigerants or fuels power HTP boilers?

HTP boilers listings record Gas / Propane combustion, with 0 Cold Climate certified models inside the boilers cohort.

DOE Regions

Where are HTP boilers compliant under 2026 federal rules?

Models meeting 13.4 SEER2 qualify in the North; 14.3 SEER2 (plus 11.7 EER2 or 9.8 at 15.2+ SEER2) is needed for Southwest split cooling, while split heat pumps require 14.3 SEER2 / 7.5 HSPF2 nationwide.

CPSC Recalls

Are any CPSC safety recalls linked to HTP residential HVAC products?

ThermalSpec counts 0 residential HVAC CPSC filings referencing HTP; verify model serial prefixes at /recalls/ before installation or service.

25C Tax Credit

Do HTP boilers receive federal Section 25C credits in 2026?

No — IRS Section 25C credits terminated December 31, 2025 ($0 federal tax credit for HTP in 2026). Check state HOMES/HEAR and local utility ENERGY STAR rebates using PD ID 2364742.

Sizing Rule

How should homeowners select among HTP's 15 boilers models?

Match HTP model capacity (Residential capacities) using an ACCA Manual J room-by-room heat load and <= 0.50 in. w.c. static pressure check rather than old unit tonnage.

Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Boilers Dataset (6rww-hpns) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 6 pages.

Comparable HVAC Climate & Cost Metros