Eco King Supreme C200 — Residential Boiler Specifications
Eco King Supreme C200 (Residential Boiler, PD ID 2240344) holds 1 ENERGY STAR certified SKU rated at 95.0% AFUE — #53 of 663 (402 tied at median), Equal to 95.0% AFUE category median. Condensing ENERGY STAR residential boiler (95.0% AFUE; exceeds 84% federal gas boiler floor). Eco King Supreme C200 — Residential Boiler Specifications benchmarks residential systems using Thermal Efficiency set at 95.0% AFUE and Cohort Rank set at #53/663.
- Thermal Efficiency
- 95.0% AFUE
- Cohort Rank
- #53/663
- Verified Combos
- 1 SKU
- Sample PD ID
- 2240344
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 87.0 - 88.1% AFUE | 148 | Peer range |
| 88.1 - 89.2% AFUE | 0 | Peer range |
| 89.2 - 90.3% AFUE | 22 | Peer range |
| 90.3 - 91.4% AFUE | 13 | Peer range |
| 91.4 - 92.6% AFUE | 3 | Peer range |
| 92.6 - 93.7% AFUE | 4 | Peer range |
| 93.7 - 94.8% AFUE | 19 | Peer range |
| 94.8 - 95.9% AFUE | 402 | This series |
| 95.9 - 97.0% AFUE | 52 | Peer range |
How does Eco King Supreme C200 rank across federal compliance and ENERGY STAR cohorts?
Eco King Supreme C200 ranks #53 of 663 (tied with 401 others at 95.0% AFUE, more efficient than 31.5% of certified series) for Max AFUE (Equal to 95.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 95.0% AFUE (+15.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2015-05-29.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max AFUE) | #53 of 663 (402 tied at median) | Equal to 95.0% AFUE category median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal Residential Boiler Minimum | PASS | Rated 95.0% AFUE vs 84% federal gas hot-water boiler baseline |
| Condensing Hydronic Design | CONDENSING | Extracts latent flue heat below 140F return water temp |
How much annual energy and operating cost does Eco King Supreme C200 require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Eco King Supreme C200 estimates reflect 1 certified SKU combination tested under PD ID 2240344.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Annual Natural Gas Consumption (50 MMBtu) | 526.3 therms/yr | 6,158 lb CO2/yr (11.7 lb/therm) |
| Estimated Annual Fuel Cost (US Median) | $763/yr | State range: $389 (ID) to $2,658 (HI) |
| Fuel Saved vs 80% AFUE Baseline | 98.7 therms/yr | $143/yr saved |
Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.
Which AHRI certified SKU combinations belong to Eco King Supreme C200?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Eco King Supreme C200 (PD ID 2240344).
| C200 | Matched AHRI Coil | — | / 95.0% AFUE |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Eco King Supreme C200, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Eco King Supreme C200: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Eco King Supreme C200 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Eco King Supreme C200 condensing combustion at 95.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Eco King Supreme C200 fit | Single-family replacement needing documented ENERGY STAR PD ID 2240344 with matching indoor air handler. |
| Skip Eco King Supreme C200 if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable residential boiler models deliver similar efficiency?
Compare Eco King Supreme C200 against CAMUS HYDRONICS LTD. VANH-0299 and closely matched residential boiler units sharing similar Max AFUE output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Eco King Supreme C200 compare with peer Residential Boiler units?
Eco King Supreme C200 holds #53 of 663 (402 tied at median) out of 663 verified residential boiler models (Equal to 95.0% AFUE category median), spanning 1 certified SKU up to 95.0% AFUE. Closest same-cohort alternatives include CAMUS HYDRONICS LTD. VANH-0299.
Where is Eco King Supreme C200 compliant for 2026 US installation?
Eco King Supreme C200: Condensing ENERGY STAR residential boiler (95.0% AFUE; exceeds 84% federal gas boiler floor). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Eco King Supreme C200 model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Eco King Supreme C200 runs 526.3 therms/yr across standard cooling/heating hours.
What capacity band and airflow does Eco King Supreme C200 cover?
Eco King Supreme C200 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Eco King Supreme C200 handle extreme weather or cold snaps?
Eco King Supreme C200 delivers steady fuel combustion independent of outdoor air temperature.
What refrigerant class and 2026 tax credit rules govern Eco King Supreme C200?
Eco King Supreme C200 specifies sealed combustion compliance (PD ID 2240344); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Eco King Supreme C200 reach 95.0% AFUE?
Peak 95.0% AFUE represents the top tested AHRI pairing for Eco King Supreme C200 (PD ID 2240344); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Eco King Supreme C200?
Eco King Supreme C200 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include CAMUS HYDRONICS LTD. VANH-0299.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Boilers Dataset (6rww-hpns) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.