---
title: "Terms of Use & Engineering Disclaimer — ThermalSpec"
url: https://myhomeheating.org/terms/
description: "Terms of use and safety disclaimer for ThermalSpec residential HVAC specifications, calculators, and state contractor directories."
---

Legal & Safety Terms

# Terms of Use & Technical Disclaimer

Terms of use and safety disclaimer for ThermalSpec residential HVAC specifications, calculators, and state contractor directories. Terms of Use & Technical Disclaimer benchmarks residential systems using Federal AC Minimum set at 13.4 - 14.3 SEER2 and Cleaner Refrigerants set at R-454B or R-32. Values trace to primary federal, state, or OEM filings supporting Terms of Use & Technical Disclaimer across single-family housing.

- **Federal AC Minimum**: 13.4 - 14.3 SEER2

- **Cleaner Refrigerants**: R-454B or R-32

- **Federal 25C Credit**: Ended Dec 31, 2025

- **Covered Homes**: Single-Family & Townhomes

## What are the verified details for No Professional Engineering, Permit, or Legal Advice?

ThermalSpec publishes reference specifications, state rate tables, and starting sizing guides compiled from official US government and manufacturer datasets. Outputs from calculators do not substitute for a certified ACCA Manual J/S/D load calculation, local building permit review, or licensed mechanical inspection.

Always hire an EPA Section 608 and state-licensed residential HVAC contractor for refrigerant recovery, leak mitigation, natural gas piping, or 240V electrical service. Evacuate and call 911 immediately if a CO alarm sounds or gas odor is detected.

## What are the verified details for Residential Scope & Statutory Safety Boundaries?

Permitted Reference Scope vs. Licensed Field Work Mandates. Benchmark rows below summarize verified data specifically for Terms of Use & Technical Disclaimer.

Permitted Reference Scope vs. Licensed Field Work Mandates

| Domain | ThermalSpec Reference Output | Mandatory Legal / Safety Boundary | Cited Authority |
|---|---|---|---|
| Heat Load & Tonnage | Preliminary physics screen (BTU/h) | Not a certified permit Manual J / D submission | ACCA / Local Building Dept. |
| Refrigerant Service | R-454B / R-32 / R-410A specs & GWP | Requires EPA Section 608 certified technician | Federal EPA Refrigerant Rules |
| Life-Safety & Gas / CO | 0-15 minute evacuation checklist | Evacuate & call 911 immediately on alarm/odor | Emergency Services / Utility |
| Equipment Scope | Single-family & townhome residential | Commercial chillers, RTUs & 3-phase excluded | ThermalSpec Scope Policy |

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Core Spec

### What primary metric defines Terms of Use & Technical Disclaimer?

Terms of Use & Technical Disclaimer anchors on Federal AC Minimum at 13.4 - 14.3 SEER2 and Cleaner Refrigerants at R-454B or R-32, sourced from federal datasets and OEM filings.

Bounds

### How are Federal 25C Credit figures verified for Terms of Use & Technical Disclaimer?

Federal 25C Credit: Ended Dec 31, 2025 and Covered Homes: Single-Family & Townhomes inside Terms of Use & Technical Disclaimer derive directly from public government data with zero paid boosts.

Exclusions

### Who falls outside Terms of Use & Technical Disclaimer applicability?

Terms of Use & Technical Disclaimer addresses single-family and townhome systems only; commercial systems and permit sizing need local engineering review.

SEER2 Rules

### How do federal regional rules govern Terms of Use & Technical Disclaimer?

Regional efficiency rules enforce 13.4 North and 14.3 South SEER2 minimums around Terms of Use & Technical Disclaimer.

A2L Spec

### Does the under-700 GWP rule affect Terms of Use & Technical Disclaimer?

2026 residential split equipment covered under Terms of Use & Technical Disclaimer transitions to R-454B or R-32 with UL 60335-2-40 sensors.

 2026 Tax

### Are 2026 federal tax credits active on Terms of Use & Technical Disclaimer?

IRS 25C ended Dec 31, 2025 under Public Law 119-21 ($0 in 2026); consult state HEAR programs alongside Terms of Use & Technical Disclaimer.

Credentials

### What technician license applies to Terms of Use & Technical Disclaimer work?

Pressurized refrigerant lines and 240V controls noted in Terms of Use & Technical Disclaimer mandate EPA Section 608 and state mechanical licensing.

Audit

### How can owners cross-check quotes on Terms of Use & Technical Disclaimer?

Confirm AHRI reference numbers, <=0.50 in. w.c. static pressure limits, and active board registration when reviewing Terms of Use & Technical Disclaimer.

## Sources

Verified numerical figures and rules trace to the 3 cited federal, state, or OEM documents listed below.

1. [40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
2. [40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-84) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 2 pages.

[ 51-State SEER2 & Utility Atlas → ](https://myhomeheating.org/states/) [ Certified Equipment Index → ](https://myhomeheating.org/equipment/)
