title: "Verification Methodology & Residential HVAC Audit Standards"
url: https://myhomeheating.org/methodology/
description: "How ThermalSpec checks every number against federal efficiency rules, ENERGY STAR datasets, state utility tables, technician wages, and public standards."
---

Source Verification Rules

# Source Verification & Data Audit Methodology

How ThermalSpec checks every number against federal efficiency rules, ENERGY STAR datasets, state utility tables, technician wages, and public standards. Source Verification & Data Audit Methodology benchmarks residential systems using Federal AC Minimum set at 13.4 - 14.3 SEER2 and Cleaner Refrigerants set at R-454B or R-32. Values trace to primary federal, state, or OEM filings supporting Source Verification & Data Audit Methodology across single-family housing.

- **Federal AC Minimum**: 13.4 - 14.3 SEER2

- **Cleaner Refrigerants**: R-454B or R-32

- **Federal 25C Credit**: Ended Dec 31, 2025

- **Covered Homes**: Single-Family & Townhomes

## What are the verified details for Zero-Invention Source Verification Rule?

Every numerical table, calculator constant, and rule published on ThermalSpec traces to an explicit entry in /sources/. Across our review process, 42,647 facts carry verified provenance while 61 un-refetched secondary facts remain held off public pages.

We respect ACCA Manual J/D copyright boundaries by labeling load calculators as starting size estimates rather than certified permit Manual J submissions, and cite ASHRAE, UL, and ICC standards strictly by section identifier and published numerical limits.

## What are the verified details for Live Dataset Coverage & Provenance Inventory?

ThermalSpec Primary Data Entities & Source Verification Counts. Benchmark rows below summarize verified data specifically for Source Verification & Data Audit Methodology.

ThermalSpec Primary Data Entities & Source Verification Counts

| Dataset / Registry | Normalized Records | Governing Standard / Portal | Scope |
|---|---|---|---|
| EPA ENERGY STAR Equipment | 15,136 SKUs -> 9,520 models | 7 Official Datasets | Residential only |
| State Energy, Climate & Labor | 51 Jurisdictions (50 + DC) | EIA / EPA eGRID / NOAA / BLS | US single-family HVAC |
| County, City & Metro Atlas | 3,144 Counties · 2,343 Cities · 389 Metros | Census ACS / IECC / FEMA / BLS | Native residential benchmarks |
| State HVAC Contractor Registries | 6,948 active firms (88 locs) | WA L&I / TX TDLR / OR BCD / CT DCP / NY DOL | >= 8 firms per city/county |
| CPSC Safety Recalls | 45 residential HVAC notices | saferproducts.gov Public Feed | Furnaces, HPs, ACs, boilers |
| Source-Checked Facts | 42,647 verified (61 held) | Source Verification Rules | Unverified held off pages |

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Core Spec

### What primary metric defines Source Verification & Data Audit Methodology?

Source Verification & Data Audit Methodology anchors on Federal AC Minimum at 13.4 - 14.3 SEER2 and Cleaner Refrigerants at R-454B or R-32, sourced from federal datasets and OEM filings.

Bounds

### How are Federal 25C Credit figures verified for Source Verification & Data Audit Methodology?

Federal 25C Credit: Ended Dec 31, 2025 and Covered Homes: Single-Family & Townhomes inside Source Verification & Data Audit Methodology derive directly from public government data with zero paid boosts.

Exclusions

### Who falls outside Source Verification & Data Audit Methodology applicability?

Source Verification & Data Audit Methodology addresses single-family and townhome systems only; commercial systems and permit sizing need local engineering review.

SEER2 Rules

### How do federal regional rules govern Source Verification & Data Audit Methodology?

Regional efficiency rules enforce 13.4 North and 14.3 South SEER2 minimums around Source Verification & Data Audit Methodology.

A2L Spec

### Does the under-700 GWP rule affect Source Verification & Data Audit Methodology?

2026 residential split equipment covered under Source Verification & Data Audit Methodology transitions to R-454B or R-32 with UL 60335-2-40 sensors.

 2026 Tax

### Are 2026 federal tax credits active on Source Verification & Data Audit Methodology?

IRS 25C ended Dec 31, 2025 under Public Law 119-21 ($0 in 2026); consult state HEAR programs alongside Source Verification & Data Audit Methodology.

Credentials

### What technician license applies to Source Verification & Data Audit Methodology work?

Pressurized refrigerant lines and 240V controls noted in Source Verification & Data Audit Methodology mandate EPA Section 608 and state mechanical licensing.

Audit

### How can owners cross-check quotes on Source Verification & Data Audit Methodology?

Confirm AHRI reference numbers, <=0.50 in. w.c. static pressure limits, and active board registration when reviewing Source Verification & Data Audit Methodology.

## Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

1. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
2. [40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-84) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
4. [ASHRAE Standards 52.2 (MERV), 62.2 (Residential Ventilation) & 15.2 (A2L Safety)](https://www.ashrae.org/technical-resources/standards-and-guidelines) — ASHRAE, ASHRAE 52.2 / 62.2 / 15.2 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 2 pages.

[ 51-State SEER2 & Utility Atlas → ](https://myhomeheating.org/states/) [ Certified Equipment Index → ](https://myhomeheating.org/equipment/)