York / Coleman / Luxaire · Gas Furnace · Fault Code RED-SOLID

# York / Coleman / Luxaire RED-SOLID: York / Coleman Solid Red LED: Board Fault / Rollout

Manual rollout switch open, internal board self-check failed, or low-voltage fuse blown. York / Coleman / Luxaire RED-SOLID: York / Coleman Solid Red LED: Board Fault / Rollout benchmarks residential systems using Manufacturer Family set at York / Coleman / Luxaire and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting York / Coleman / Luxaire RED-SOLID: York / Coleman Solid Red LED: Board Fault / Rollout across single-family housing. York / Coleman Furnace LED Codes — Solid Red: York / Coleman / Luxaire RED-SOLID: Manual rollout switch open, internal board self-check failed, or low-voltage fuse blown. Pro fix: Check 3A/5A board fuse, rollout continuity, and heat exchanger condition..

- **Manufacturer Family**: York / Coleman / Luxaire

- **Control System**: Gas Furnace

- **Fault Code**: RED-SOLID

- **LED Blink Sequence**: Continuous solid red LED (unblinking)

- **Slow / Fast Pulses**: 1 slow / 0 fast

- **Control Supply Voltage**: 24 VAC Board / 5 min Breaker Wait

Life-Safety Protocol: Carbon Monoxide, Natural Gas, or Electrical Fire

If a carbon monoxide alarm sounds, you smell natural gas or burning wiring, or a breaker box is sparking: leave the house right away and call **911** or your gas utility emergency line from outside. Do not flip light switches or breaker panels if you smell gas.

## How do you identify fault code RED-SOLID on York / Coleman / Luxaire diagnostic LEDs?

Manual rollout switch open, internal board self-check failed, or low-voltage fuse blown. York / Coleman / Luxaire RED-SOLID: York / Coleman Solid Red LED: Board Fault / Rollout uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.

Pattern: Continuous solid red LED (unblinking)

| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| **Slow LED Pulses** | 1 x 520 ms amber (800 ms) | First digit / slow code cadence |
| **Total Cycle Period** | 2,000 ms | Includes 1,200 ms pause between repeats |
| **External Static Ceiling** | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| **24VAC Control Supply** | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |

## Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

### External Verification Checklist

- Check if rollout switch tripped; do not reset repeatedly
- Verify working CO alarms

Licensed Technician

### Professional Diagnostic Scope

Check 3A/5A board fuse, rollout continuity, and heat exchanger condition.

**York / Coleman Furnace LED Codes — Solid Red:** York / Coleman / Luxaire RED-SOLID: Manual rollout switch open, internal board self-check failed, or low-voltage fuse blown.

## Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code RED-SOLID temporarily or alternates with pressure, flame, or limit switch lockouts.

York / Coleman / LuxaireCode 1-FLASH

### [York / Coleman / Luxaire 1-FLASH: York / Coleman 1 Flash: Flame Failed (Retry)](https://myhomeheating.org/error-codes/york/code-1-flash-ignition-retry/)

York / Coleman / LuxaireCode 2-FLASH

### [York / Coleman / Luxaire 2-FLASH: York / Coleman 2 Flashes: Pressure Switch Stuck Closed](https://myhomeheating.org/error-codes/york/code-2-flash-pressure-closed/)

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

York / Coleman / Luxaire #RED-SOLID

### Why does York / Coleman / Luxaire blink fault code RED-SOLID?

York / Coleman / Luxaire Gas Furnace code RED-SOLID indicates: Manual rollout switch open, internal board self-check failed, or low-voltage fuse blown..

Cadence

### What LED timing marks York / Coleman / Luxaire code RED-SOLID?

On York / Coleman / Luxaire boards, Continuous solid red LED (unblinking) fires 1 slow and 0 fast LED pulses repeatedly.

Check 1

### Which external check applies first to York / Coleman / Luxaire RED-SOLID?

First on York / Coleman / Luxaire code RED-SOLID: Check if rollout switch tripped; do not reset repeatedly; secondary check: Verify working CO alarms.

Manual Ref

### What does York / Coleman Furnace LED Codes — Solid Red document for code RED-SOLID?

York / Coleman / Luxaire RED-SOLID: Manual rollout switch open, internal board self-check failed, or low-voltage fuse blown. — recorded under York / Coleman Furnace LED Codes — Solid Red for York / Coleman / Luxaire Gas Furnace equipment.

Pro Fix

### How do techs repair York / Coleman / Luxaire Gas Furnace fault RED-SOLID?

Authorized repair on York / Coleman / Luxaire code RED-SOLID: Check 3A/5A board fuse, rollout continuity, and heat exchanger condition. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

### Why avoid jumping switches on York / Coleman / Luxaire code RED-SOLID?

Combustion safety lockouts block CO or delayed ignition hazards on York / Coleman / Luxaire code RED-SOLID.

Reset

### Will flipping the breaker clear York / Coleman / Luxaire code RED-SOLID?

One brief power cycle resets transient York / Coleman / Luxaire code RED-SOLID, while repeat trips need mechanical testing.

Credentials

### What license applies to York / Coleman / Luxaire Gas Furnace fault RED-SOLID?

Licensed mechanical diagnostic credentials apply for York / Coleman / Luxaire code RED-SOLID.

## Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

1. [York / Coleman / Luxaire Residential Furnace & Split Heat Pump Service Literature](https://www.york.com/residential-equipment/heating-and-cooling) — Johnson Controls / York, York Public Technical Library (retrieved 2026-11-25)
2. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

[ All Furnace & Heat Pump Fault Codes → ](https://myhomeheating.org/error-codes/) [ 0-15 Min HVAC Emergency Triage → ](https://myhomeheating.org/emergency/) [ York / Coleman / Luxaire RAPID-AMBER: York / Coleman Rapid → ](https://myhomeheating.org/error-codes/york/code-rapid-amber-weak-flame/) [ Mitsubishi Code P1: Intake Air Thermistor Error → ](https://myhomeheating.org/error-codes/mitsubishi/code-p1-room-thermistor/) [ Mitsubishi Code P2: Liquid Pipe Thermistor Error → ](https://myhomeheating.org/error-codes/mitsubishi/code-p2-pipe-thermistor/)

Emergency & Parts Links

[Emergency Safety Guides →](https://myhomeheating.org/emergency/) [Verify State-Licensed Techs](https://myhomeheating.org/pros/)