---
title: "York / Coleman / Luxaire 6-FLASH: 1-Hour Ignition Lockout"
url: https://myhomeheating.org/error-codes/york/code-6-flash-lockout-igniter/
description: "York / Coleman / Luxaire Gas Furnace fault 6-FLASH (6 red flashes on control board LED): pulse timing, safe filter/vent checks, and licensed technician."
---

York / Coleman / Luxaire · Gas Furnace · Fault Code 6-FLASH

# York / Coleman / Luxaire 6-FLASH: York / Coleman 6 Flashes: 1-Hour Ignition Lockout

Exhausted all ignition retries; control board enters 60-minute soft lockout. York / Coleman / Luxaire 6-FLASH: York / Coleman 6 Flashes: 1-Hour Ignition Lockout benchmarks residential systems using Manufacturer Family set at York / Coleman / Luxaire and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting York / Coleman / Luxaire 6-FLASH: York / Coleman 6 Flashes: 1-Hour Ignition Lockout across single-family housing. York / Coleman Furnace LED Codes — 6 Flashes: York / Coleman / Luxaire 6-FLASH: Exhausted all ignition retries; control board enters 60-minute soft lockout. Pro fix: Test igniter ohms, gas valve 24VAC supply, and flame rectification uA..

- **Manufacturer Family**: York / Coleman / Luxaire

- **Control System**: Gas Furnace

- **Fault Code**: 6-FLASH

- **LED Blink Sequence**: 6 red flashes on control board LED

- **Slow / Fast Pulses**: 0 slow / 6 fast

- **Control Supply Voltage**: 24 VAC Board / 5 min Breaker Wait

Life-Safety Protocol: Carbon Monoxide, Natural Gas, or Electrical Fire

If a carbon monoxide alarm sounds, you smell natural gas or burning wiring, or a breaker box is sparking: leave the house right away and call **911** or your gas utility emergency line from outside. Do not flip light switches or breaker panels if you smell gas.

## How do you identify fault code 6-FLASH on York / Coleman / Luxaire diagnostic LEDs?

Exhausted all ignition retries; control board enters 60-minute soft lockout. York / Coleman / Luxaire 6-FLASH: York / Coleman 6 Flashes: 1-Hour Ignition Lockout uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.

Pattern: 6 red flashes on control board LED

| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| **Fast LED Pulses** | 6 x 200 ms red (2,280 ms) | Second digit / rapid fault pulses |
| **Total Cycle Period** | 3,480 ms | Includes 1,200 ms pause between repeats |
| **External Static Ceiling** | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| **24VAC Control Supply** | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |

## Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

### External Verification Checklist

- Check main gas shutoff valve position
- Record flash count before cycling power

Licensed Technician

### Professional Diagnostic Scope

Test igniter ohms, gas valve 24VAC supply, and flame rectification uA.

**York / Coleman Furnace LED Codes — 6 Flashes:** York / Coleman / Luxaire 6-FLASH: Exhausted all ignition retries; control board enters 60-minute soft lockout.

## Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code 6-FLASH temporarily or alternates with pressure, flame, or limit switch lockouts.

York / Coleman / LuxaireCode 1-FLASH

### [York / Coleman / Luxaire 1-FLASH: York / Coleman 1 Flash: Flame Failed (Retry)](https://myhomeheating.org/error-codes/york/code-1-flash-ignition-retry/)

York / Coleman / LuxaireCode 2-FLASH

### [York / Coleman / Luxaire 2-FLASH: York / Coleman 2 Flashes: Pressure Switch Stuck Closed](https://myhomeheating.org/error-codes/york/code-2-flash-pressure-closed/)

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

York / Coleman / Luxaire #6-FLASH

### Why does York / Coleman / Luxaire blink fault code 6-FLASH?

York / Coleman / Luxaire Gas Furnace code 6-FLASH indicates: Exhausted all ignition retries; control board enters 60-minute soft lockout..

Cadence

### What LED timing marks York / Coleman / Luxaire code 6-FLASH?

On York / Coleman / Luxaire boards, 6 red flashes on control board LED fires 0 slow and 6 fast LED pulses repeatedly.

Check 1

### Which external check applies first to York / Coleman / Luxaire 6-FLASH?

First on York / Coleman / Luxaire code 6-FLASH: Check main gas shutoff valve position; secondary check: Record flash count before cycling power.

Manual Ref

### What does York / Coleman Furnace LED Codes — 6 Flashes document for code 6-FLASH?

York / Coleman / Luxaire 6-FLASH: Exhausted all ignition retries; control board enters 60-minute soft lockout. — recorded under York / Coleman Furnace LED Codes — 6 Flashes for York / Coleman / Luxaire Gas Furnace equipment.

Pro Fix

### How do techs repair York / Coleman / Luxaire Gas Furnace fault 6-FLASH?

Authorized repair on York / Coleman / Luxaire code 6-FLASH: Test igniter ohms, gas valve 24VAC supply, and flame rectification uA. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

### Why avoid jumping switches on York / Coleman / Luxaire code 6-FLASH?

Combustion safety lockouts block CO or delayed ignition hazards on York / Coleman / Luxaire code 6-FLASH.

Reset

### Will flipping the breaker clear York / Coleman / Luxaire code 6-FLASH?

One brief power cycle resets transient York / Coleman / Luxaire code 6-FLASH, while repeat trips need mechanical testing.

Credentials

### What license applies to York / Coleman / Luxaire Gas Furnace fault 6-FLASH?

Licensed mechanical diagnostic credentials apply for York / Coleman / Luxaire code 6-FLASH.

## Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

1. [York / Coleman / Luxaire Residential Furnace & Split Heat Pump Service Literature](https://www.york.com/residential-equipment/heating-and-cooling) — Johnson Controls / York, York Public Technical Library (retrieved 2026-11-25)
2. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

[ All Furnace & Heat Pump Fault Codes → ](https://myhomeheating.org/error-codes/) [ 0-15 Min HVAC Emergency Triage → ](https://myhomeheating.org/emergency/) [ York / Coleman / Luxaire 7-FLASH: York / Coleman 7 Flashes → ](https://myhomeheating.org/error-codes/york/code-7-flash-igniter-retries/) [ York / Coleman / Luxaire 8-FLASH: York / Coleman 8 Flashes → ](https://myhomeheating.org/error-codes/york/code-8-flash-flame-dropout/) [ York / Coleman / Luxaire 9-FLASH: York / Coleman 9 Flashes → ](https://myhomeheating.org/error-codes/york/code-9-flash-reversed-polarity/)

Emergency & Parts Links

[Emergency Safety Guides →](https://myhomeheating.org/emergency/) [Verify State-Licensed Techs](https://myhomeheating.org/pros/)
