title: "York / Coleman / Luxaire 5-FLASH: Flame Sensed Without Call"
url: https://myhomeheating.org/error-codes/york/code-5-flash-flame-no-call/
description: "York / Coleman / Luxaire Gas Furnace fault 5-FLASH (5 red flashes on control board LED): pulse timing, safe filter/vent checks, and licensed technician."
---

York / Coleman / Luxaire · Gas Furnace · Fault Code 5-FLASH

# York / Coleman / Luxaire 5-FLASH: York / Coleman 5 Flashes: Flame Sensed Without Call

Flame sensor detected flame while gas valve was commanded OFF. York / Coleman / Luxaire 5-FLASH: York / Coleman 5 Flashes: Flame Sensed Without Call benchmarks residential systems using Manufacturer Family set at York / Coleman / Luxaire and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting York / Coleman / Luxaire 5-FLASH: York / Coleman 5 Flashes: Flame Sensed Without Call across single-family housing. York / Coleman Furnace LED Codes — 5 Flashes: York / Coleman / Luxaire 5-FLASH: Flame sensor detected flame while gas valve was commanded OFF. Pro fix: Inspect gas valve seating and flame rod wire insulation..

- **Manufacturer Family**: York / Coleman / Luxaire

- **Control System**: Gas Furnace

- **Fault Code**: 5-FLASH

- **LED Blink Sequence**: 5 red flashes on control board LED

- **Slow / Fast Pulses**: 0 slow / 5 fast

- **Control Supply Voltage**: 24 VAC Board / 5 min Breaker Wait

Life-Safety Protocol: Carbon Monoxide, Natural Gas, or Electrical Fire

If a carbon monoxide alarm sounds, you smell natural gas or burning wiring, or a breaker box is sparking: leave the house right away and call **911** or your gas utility emergency line from outside. Do not flip light switches or breaker panels if you smell gas.

## How do you identify fault code 5-FLASH on York / Coleman / Luxaire diagnostic LEDs?

Flame sensor detected flame while gas valve was commanded OFF. York / Coleman / Luxaire 5-FLASH: York / Coleman 5 Flashes: Flame Sensed Without Call uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.

Pattern: 5 red flashes on control board LED

| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| **Fast LED Pulses** | 5 x 200 ms red (1,900 ms) | Second digit / rapid fault pulses |
| **Total Cycle Period** | 3,100 ms | Includes 1,200 ms pause between repeats |
| **External Static Ceiling** | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| **24VAC Control Supply** | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |

## Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

### External Verification Checklist

- Turn thermostat OFF and inspect sight glass; close gas valve and evacuate if flame persists

Licensed Technician

### Professional Diagnostic Scope

Inspect gas valve seating and flame rod wire insulation.

**York / Coleman Furnace LED Codes — 5 Flashes:** York / Coleman / Luxaire 5-FLASH: Flame sensor detected flame while gas valve was commanded OFF.

## Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code 5-FLASH temporarily or alternates with pressure, flame, or limit switch lockouts.

York / Coleman / LuxaireCode 1-FLASH

### [York / Coleman / Luxaire 1-FLASH: York / Coleman 1 Flash: Flame Failed (Retry)](https://myhomeheating.org/error-codes/york/code-1-flash-ignition-retry/)

York / Coleman / LuxaireCode 2-FLASH

### [York / Coleman / Luxaire 2-FLASH: York / Coleman 2 Flashes: Pressure Switch Stuck Closed](https://myhomeheating.org/error-codes/york/code-2-flash-pressure-closed/)

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

York / Coleman / Luxaire #5-FLASH

### Why does York / Coleman / Luxaire blink fault code 5-FLASH?

York / Coleman / Luxaire Gas Furnace code 5-FLASH indicates: Flame sensor detected flame while gas valve was commanded OFF..

Cadence

### What LED timing marks York / Coleman / Luxaire code 5-FLASH?

On York / Coleman / Luxaire boards, 5 red flashes on control board LED fires 0 slow and 5 fast LED pulses repeatedly.

Check 1

### Which external check applies first to York / Coleman / Luxaire 5-FLASH?

First on York / Coleman / Luxaire code 5-FLASH: Turn thermostat OFF and inspect sight glass; close gas valve and evacuate if flame persists; secondary check: inspect main air filter restriction.

Manual Ref

### What does York / Coleman Furnace LED Codes — 5 Flashes document for code 5-FLASH?

York / Coleman / Luxaire 5-FLASH: Flame sensor detected flame while gas valve was commanded OFF. — recorded under York / Coleman Furnace LED Codes — 5 Flashes for York / Coleman / Luxaire Gas Furnace equipment.

Pro Fix

### How do techs repair York / Coleman / Luxaire Gas Furnace fault 5-FLASH?

Authorized repair on York / Coleman / Luxaire code 5-FLASH: Inspect gas valve seating and flame rod wire insulation. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

### Why avoid jumping switches on York / Coleman / Luxaire code 5-FLASH?

Combustion safety lockouts block CO or delayed ignition hazards on York / Coleman / Luxaire code 5-FLASH.

Reset

### Will flipping the breaker clear York / Coleman / Luxaire code 5-FLASH?

One brief power cycle resets transient York / Coleman / Luxaire code 5-FLASH, while repeat trips need mechanical testing.

Credentials

### What license applies to York / Coleman / Luxaire Gas Furnace fault 5-FLASH?

Licensed mechanical diagnostic credentials apply for York / Coleman / Luxaire code 5-FLASH.

## Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

1. [York / Coleman / Luxaire Residential Furnace & Split Heat Pump Service Literature](https://www.york.com/residential-equipment/heating-and-cooling) — Johnson Controls / York, York Public Technical Library (retrieved 2026-11-25)
2. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

[ All Furnace & Heat Pump Fault Codes → ](https://myhomeheating.org/error-codes/) [ 0-15 Min HVAC Emergency Triage → ](https://myhomeheating.org/emergency/) [ York / Coleman / Luxaire 6-FLASH: York / Coleman 6 Flashes → ](https://myhomeheating.org/error-codes/york/code-6-flash-lockout-igniter/) [ York / Coleman / Luxaire 7-FLASH: York / Coleman 7 Flashes → ](https://myhomeheating.org/error-codes/york/code-7-flash-igniter-retries/) [ York / Coleman / Luxaire 8-FLASH: York / Coleman 8 Flashes → ](https://myhomeheating.org/error-codes/york/code-8-flash-flame-dropout/)

Emergency & Parts Links

[Emergency Safety Guides →](https://myhomeheating.org/emergency/) [Verify State-Licensed Techs](https://myhomeheating.org/pros/)