Rheem / Ruud · Gas Furnace · Fault Code 44

# Rheem / Ruud Code 44: Low-Fire Pressure Switch Open

Low-stage draft switch failed to close on two-stage condensing furnace. Rheem / Ruud Code 44: Low-Fire Pressure Switch Open benchmarks residential systems using Manufacturer Family set at Rheem / Ruud and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Rheem / Ruud Code 44: Low-Fire Pressure Switch Open across single-family housing. Rheem Gas Furnace Diagnostic Table — Code 44: Rheem / Ruud 44: Low-stage draft switch failed to close on two-stage condensing furnace. Pro fix: Flush condensate trap and measure low-fire inducer vacuum with manometer..

- **Manufacturer Family**: Rheem / Ruud

- **Control System**: Gas Furnace

- **Fault Code**: 44

- **LED Blink Sequence**: Dual 7-segment display showing 44

- **Slow / Fast Pulses**: 4 slow / 4 fast

- **Control Supply Voltage**: 24 VAC Board / 5 min Breaker Wait

Life-Safety Protocol: Carbon Monoxide, Natural Gas, or Electrical Fire

If a carbon monoxide alarm sounds, you smell natural gas or burning wiring, or a breaker box is sparking: leave the house right away and call **911** or your gas utility emergency line from outside. Do not flip light switches or breaker panels if you smell gas.

## How do you identify fault code 44 on Rheem / Ruud diagnostic LEDs?

Low-stage draft switch failed to close on two-stage condensing furnace. Rheem / Ruud Code 44: Low-Fire Pressure Switch Open uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.

Pattern: Dual 7-segment display showing 44

| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| **Slow LED Pulses** | 4 x 520 ms amber (3,200 ms) | First digit / slow code cadence |
| **Fast LED Pulses** | 4 x 200 ms red (1,520 ms) | Second digit / rapid fault pulses |
| **Total Cycle Period** | 5,920 ms | Includes 1,200 ms pause between repeats |
| **External Static Ceiling** | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| **24VAC Control Supply** | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |

## Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

### External Verification Checklist

- Inspect outdoor PVC exhaust/intake terminations for frost or debris

Licensed Technician

### Professional Diagnostic Scope

Flush condensate trap and measure low-fire inducer vacuum with manometer.

**Rheem Gas Furnace Diagnostic Table — Code 44:** Rheem / Ruud 44: Low-stage draft switch failed to close on two-stage condensing furnace.

## Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code 44 temporarily or alternates with pressure, flame, or limit switch lockouts.

Rheem / RuudCode 57

### [Rheem / Ruud Code 57: Pressure Switch Stuck Open](https://myhomeheating.org/error-codes/rheem/code-57-pressure-switch-open/)

Rheem / RuudCode 10

### [Rheem / Ruud Code 10: One-Hour Ignition Lockout](https://myhomeheating.org/error-codes/rheem/code-10-ignition-lockout/)

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Rheem / Ruud #44

### Why does Rheem / Ruud blink fault code 44?

Rheem / Ruud Gas Furnace code 44 indicates: Low-stage draft switch failed to close on two-stage condensing furnace..

Cadence

### What LED timing marks Rheem / Ruud code 44?

On Rheem / Ruud boards, Dual 7-segment display showing 44 fires 4 slow and 4 fast LED pulses repeatedly.

Check 1

### Which external check applies first to Rheem / Ruud 44?

First on Rheem / Ruud code 44: Inspect outdoor PVC exhaust/intake terminations for frost or debris; secondary check: inspect main air filter restriction.

Manual Ref

### What does Rheem Gas Furnace Diagnostic Table — Code 44 document for code 44?

Rheem / Ruud 44: Low-stage draft switch failed to close on two-stage condensing furnace. — recorded under Rheem Gas Furnace Diagnostic Table — Code 44 for Rheem / Ruud Gas Furnace equipment.

Pro Fix

### How do techs repair Rheem / Ruud Gas Furnace fault 44?

Authorized repair on Rheem / Ruud code 44: Flush condensate trap and measure low-fire inducer vacuum with manometer. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

### Why avoid jumping switches on Rheem / Ruud code 44?

Combustion safety lockouts block CO or delayed ignition hazards on Rheem / Ruud code 44.

Reset

### Will flipping the breaker clear Rheem / Ruud code 44?

One brief power cycle resets transient Rheem / Ruud code 44, while repeat trips need mechanical testing.

Credentials

### What license applies to Rheem / Ruud Gas Furnace fault 44?

Licensed mechanical diagnostic credentials apply for Rheem / Ruud code 44.

## Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

1. [Rheem / Ruud Residential Heat Pump & Furnace Documentation (B-Terminal Valve)](https://www.rheem.com/products/residential/heating-and-cooling/) — Rheem Manufacturing, Rheem Residential Specs (retrieved 2026-11-23)
2. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

[ All Furnace & Heat Pump Fault Codes → ](https://myhomeheating.org/error-codes/) [ 0-15 Min HVAC Emergency Triage → ](https://myhomeheating.org/emergency/) [ Rheem / Ruud Code 45: Low-Fire Pressure Switch Closed → ](https://myhomeheating.org/error-codes/rheem/code-45-low-pressure-closed/) [ Rheem / Ruud Code 55: High-Fire Pressure Switch Closed → ](https://myhomeheating.org/error-codes/rheem/code-55-pressure-switch-closed/) [ Rheem / Ruud Code 58: Condensate Water Sensor Triggered → ](https://myhomeheating.org/error-codes/rheem/code-58-water-sense-fault/)
