Mitsubishi Electric · Mini-Split Heat Pump · Fault Code P2

# Mitsubishi Code P2: Liquid Pipe Thermistor Error

Indoor liquid-line coil thermistor (TH2) disconnected or out of resistance curve. Mitsubishi Code P2: Liquid Pipe Thermistor Error benchmarks residential systems using Manufacturer Family set at Mitsubishi Electric and Control System set at Mini-Split Heat Pump. Values trace to primary federal, state, or OEM filings supporting Mitsubishi Code P2: Liquid Pipe Thermistor Error across single-family housing. Mitsubishi MyLinkDrive Service Manual — Code P2: Mitsubishi Electric P2: Indoor liquid-line coil thermistor (TH2) disconnected or out of resistance curve. Pro fix: Measure TH2 sensor kohms at ambient pipe temp and inspect PCB plug CN44..

- **Manufacturer Family**: Mitsubishi Electric

- **Control System**: Mini-Split Heat Pump

- **Fault Code**: P2

- **LED Blink Sequence**: 2 LED flashes / P2 on wired remote

- **Slow / Fast Pulses**: 0 slow / 2 fast

- **Control Supply Voltage**: 24 VAC Board / 5 min Breaker Wait

Certified Refrigerant & Safety Notice

Servicing HVAC refrigerant lines (R-410A, R-454B, R-32, or R-22) requires an EPA-certified technician. Newer R-454B and R-32 systems also include built-in leak sensors that shut off the outdoor unit and run the indoor fan if a leak occurs.

## How do you identify fault code P2 on Mitsubishi Electric diagnostic LEDs?

Indoor liquid-line coil thermistor (TH2) disconnected or out of resistance curve. Mitsubishi Code P2: Liquid Pipe Thermistor Error uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.

Pattern: 2 LED flashes / P2 on wired remote

| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| **Fast LED Pulses** | 2 x 200 ms red (760 ms) | Second digit / rapid fault pulses |
| **Total Cycle Period** | 1,960 ms | Includes 1,200 ms pause between repeats |
| **External Static Ceiling** | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| **24VAC Control Supply** | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |

## Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

### External Verification Checklist

- Do not open indoor control box while breaker is energized

Licensed Technician

### Professional Diagnostic Scope

Measure TH2 sensor kohms at ambient pipe temp and inspect PCB plug CN44.

**Mitsubishi MyLinkDrive Service Manual — Code P2:** Mitsubishi Electric P2: Indoor liquid-line coil thermistor (TH2) disconnected or out of resistance curve.

## Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code P2 temporarily or alternates with pressure, flame, or limit switch lockouts.

Mitsubishi ElectricCode P6

### [Mitsubishi Code P6 / U1: Freezing or Overheating Protection](https://myhomeheating.org/error-codes/mitsubishi/code-p6-freezing-overheating/)

Mitsubishi ElectricCode P1

### [Mitsubishi Code P1: Intake Air Thermistor Error](https://myhomeheating.org/error-codes/mitsubishi/code-p1-room-thermistor/)

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Mitsubishi Electric #P2

### Why does Mitsubishi Electric blink fault code P2?

Mitsubishi Electric Mini-Split Heat Pump code P2 indicates: Indoor liquid-line coil thermistor (TH2) disconnected or out of resistance curve..

Cadence

### What LED timing marks Mitsubishi Electric code P2?

On Mitsubishi Electric boards, 2 LED flashes / P2 on wired remote fires 0 slow and 2 fast LED pulses repeatedly.

Check 1

### Which external check applies first to Mitsubishi Electric P2?

First on Mitsubishi Electric code P2: Do not open indoor control box while breaker is energized; secondary check: inspect main air filter restriction.

Manual Ref

### What does Mitsubishi MyLinkDrive Service Manual — Code P2 document for code P2?

Mitsubishi Electric P2: Indoor liquid-line coil thermistor (TH2) disconnected or out of resistance curve. — recorded under Mitsubishi MyLinkDrive Service Manual — Code P2 for Mitsubishi Electric Mini-Split Heat Pump equipment.

Pro Fix

### How do techs repair Mitsubishi Electric Mini-Split Heat Pump fault P2?

Authorized repair on Mitsubishi Electric code P2: Measure TH2 sensor kohms at ambient pipe temp and inspect PCB plug CN44. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

### Why avoid jumping switches on Mitsubishi Electric code P2?

Relay lockouts protect compressor windings on Mitsubishi Electric code P2.

Reset

### Will flipping the breaker clear Mitsubishi Electric code P2?

One brief power cycle resets transient Mitsubishi Electric code P2, while repeat trips need mechanical testing.

Credentials

### What license applies to Mitsubishi Electric Mini-Split Heat Pump fault P2?

EPA 608 clearance governs refrigerant work for Mitsubishi Electric code P2.

## Sources

Verified numerical figures and rules trace to the 3 cited federal, state, or OEM documents listed below.

1. [Mitsubishi Electric Trane HVAC US MyLinkDrive Service & Fault Manuals](https://mylinkdrive.com/) — Mitsubishi Electric Trane HVAC US, MyLinkDrive Public (retrieved 2026-11-23)
2. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
3. [40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

[ All Furnace & Heat Pump Fault Codes → ](https://myhomeheating.org/error-codes/) [ 0-15 Min HVAC Emergency Triage → ](https://myhomeheating.org/emergency/) [ Mitsubishi Code P4: Condensate Drain Sensor Open → ](https://myhomeheating.org/error-codes/mitsubishi/code-p4-drain-float-sensor/) [ Mitsubishi Code P5: Condensate Drain Pump Overflow → ](https://myhomeheating.org/error-codes/mitsubishi/code-p5-drain-overflow/) [ Mitsubishi Code P8: Pipe Temperature Abnormality → ](https://myhomeheating.org/error-codes/mitsubishi/code-p8-pipe-temp-abnormality/)
