title: "Lennox 290: Igniter Relay / Circuit Open"
url: https://myhomeheating.org/error-codes/lennox/code-290-igniter-circuit-fault/
description: "Lennox Gas Furnace fault 290 (7-segment LED showing 290): pulse timing, safe filter/vent checks, and licensed technician diagnostics."
---

Lennox · Gas Furnace · Fault Code 290

# Lennox Code 290: Igniter Relay / Circuit Open

Control board sensed open or faulty hot-surface igniter circuit during pre-ignition check. Lennox Code 290: Igniter Relay / Circuit Open benchmarks residential systems using Manufacturer Family set at Lennox and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Lennox Code 290: Igniter Relay / Circuit Open across single-family housing. Lennox Diagnostic Codes — 290: Lennox 290: Control board sensed open or faulty hot-surface igniter circuit during pre-ignition check. Pro fix: Ohm igniter unplugged (check hairline crack) and verify igniter relay output voltage..

- **Manufacturer Family**: Lennox

- **Control System**: Gas Furnace

- **Fault Code**: 290

- **LED Blink Sequence**: 7-segment LED showing 290

- **Slow / Fast Pulses**: 2 slow / 9 fast

- **Control Supply Voltage**: 24 VAC Board / 5 min Breaker Wait

Life-Safety Protocol: Carbon Monoxide, Natural Gas, or Electrical Fire

If a carbon monoxide alarm sounds, you smell natural gas or burning wiring, or a breaker box is sparking: leave the house right away and call **911** or your gas utility emergency line from outside. Do not flip light switches or breaker panels if you smell gas.

## How do you identify fault code 290 on Lennox diagnostic LEDs?

Control board sensed open or faulty hot-surface igniter circuit during pre-ignition check. Lennox Code 290: Igniter Relay / Circuit Open uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.

Pattern: 7-segment LED showing 290

| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| **Slow LED Pulses** | 2 x 520 ms amber (1,600 ms) | First digit / slow code cadence |
| **Fast LED Pulses** | 9 x 200 ms red (3,420 ms) | Second digit / rapid fault pulses |
| **Total Cycle Period** | 6,220 ms | Includes 1,200 ms pause between repeats |
| **External Static Ceiling** | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| **24VAC Control Supply** | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |

## Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

### External Verification Checklist

- Wait for cool-down and avoid tapping igniter assembly

Licensed Technician

### Professional Diagnostic Scope

Ohm igniter unplugged (check hairline crack) and verify igniter relay output voltage.

**Lennox Diagnostic Codes — 290:** Lennox 290: Control board sensed open or faulty hot-surface igniter circuit during pre-ignition check.

## Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code 290 temporarily or alternates with pressure, flame, or limit switch lockouts.

LennoxCode 154

### [Lennox Code 154 / E250: Primary Limit Open or Airflow Fault](https://myhomeheating.org/error-codes/lennox/code-154-low-ambient-or-pressure/)

LennoxCode 110

### [Lennox Code 110: Low AC Line Voltage (< 90VAC)](https://myhomeheating.org/error-codes/lennox/code-110-low-line-voltage/)

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Lennox #290

### Why does Lennox blink fault code 290?

Lennox Gas Furnace code 290 indicates: Control board sensed open or faulty hot-surface igniter circuit during pre-ignition check..

Cadence

### What LED timing marks Lennox code 290?

On Lennox boards, 7-segment LED showing 290 fires 2 slow and 9 fast LED pulses repeatedly.

Check 1

### Which external check applies first to Lennox 290?

First on Lennox code 290: Wait for cool-down and avoid tapping igniter assembly; secondary check: inspect main air filter restriction.

Manual Ref

### What does Lennox Diagnostic Codes — 290 document for code 290?

Lennox 290: Control board sensed open or faulty hot-surface igniter circuit during pre-ignition check. — recorded under Lennox Diagnostic Codes — 290 for Lennox Gas Furnace equipment.

Pro Fix

### How do techs repair Lennox Gas Furnace fault 290?

Authorized repair on Lennox code 290: Ohm igniter unplugged (check hairline crack) and verify igniter relay output voltage. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

### Why avoid jumping switches on Lennox code 290?

Combustion safety lockouts block CO or delayed ignition hazards on Lennox code 290.

Reset

### Will flipping the breaker clear Lennox code 290?

One brief power cycle resets transient Lennox code 290, while repeat trips need mechanical testing.

Credentials

### What license applies to Lennox Gas Furnace fault 290?

Licensed mechanical diagnostic credentials apply for Lennox code 290.

## Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

1. [Lennox Residential Public Product & Warranty Documentation](https://www.lennox.com/residential/products/resources/manuals/) — Lennox International (Public Portal), Lennox Public Portal (retrieved 2026-11-23)
2. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

[ All Furnace & Heat Pump Fault Codes → ](https://myhomeheating.org/error-codes/) [ 0-15 Min HVAC Emergency Triage → ](https://myhomeheating.org/emergency/) [ Lennox Code 310: Rollout Switch Open (Manual Reset) → ](https://myhomeheating.org/error-codes/lennox/code-310-rollout-switch-open/) [ Lennox Code 311: High-Stage Pressure Switch Open → ](https://myhomeheating.org/error-codes/lennox/code-311-high-heat-pressure-open/) [ Lennox Code 400: A2L Refrigerant Sensor Mitigation → ](https://myhomeheating.org/error-codes/lennox/code-400-a2l-rds-mitigation/)

Emergency & Parts Links

[Emergency Safety Guides →](https://myhomeheating.org/emergency/) [Verify State-Licensed Techs](https://myhomeheating.org/pros/)