title: "Lennox 272: Pressure Switch Opened During Run"
url: https://myhomeheating.org/error-codes/lennox/code-272-pressure-switch-open-run/
description: "Lennox Gas Furnace fault 272 (7-segment LED showing 272): pulse timing, safe filter/vent checks, and licensed technician diagnostics."
---

Lennox · Gas Furnace · Fault Code 272

# Lennox Code 272: Pressure Switch Opened During Run

Draft switch opened mid-cycle after ignition, commonly from surging condensate in exhaust pipe. Lennox Code 272: Pressure Switch Opened During Run benchmarks residential systems using Manufacturer Family set at Lennox and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Lennox Code 272: Pressure Switch Opened During Run across single-family housing. Lennox Diagnostic Codes — 272: Lennox 272: Draft switch opened mid-cycle after ignition, commonly from surging condensate in exhaust pipe. Pro fix: Pull condensate drain trap and test inducer vacuum stability during full heat run..

- **Manufacturer Family**: Lennox

- **Control System**: Gas Furnace

- **Fault Code**: 272

- **LED Blink Sequence**: 7-segment LED showing 272

- **Slow / Fast Pulses**: 2 slow / 7 fast

- **Control Supply Voltage**: 24 VAC Board / 5 min Breaker Wait

Life-Safety Protocol: Carbon Monoxide, Natural Gas, or Electrical Fire

If a carbon monoxide alarm sounds, you smell natural gas or burning wiring, or a breaker box is sparking: leave the house right away and call **911** or your gas utility emergency line from outside. Do not flip light switches or breaker panels if you smell gas.

## How do you identify fault code 272 on Lennox diagnostic LEDs?

Draft switch opened mid-cycle after ignition, commonly from surging condensate in exhaust pipe. Lennox Code 272: Pressure Switch Opened During Run uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.

Pattern: 7-segment LED showing 272

| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| **Slow LED Pulses** | 2 x 520 ms amber (1,600 ms) | First digit / slow code cadence |
| **Fast LED Pulses** | 7 x 200 ms red (2,660 ms) | Second digit / rapid fault pulses |
| **Total Cycle Period** | 5,460 ms | Includes 1,200 ms pause between repeats |
| **External Static Ceiling** | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| **24VAC Control Supply** | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |

## Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

### External Verification Checklist

- Inspect horizontal PVC exhaust pipe slope if accessible
- Check outdoor vent end for wind/snow

Licensed Technician

### Professional Diagnostic Scope

Pull condensate drain trap and test inducer vacuum stability during full heat run.

**Lennox Diagnostic Codes — 272:** Lennox 272: Draft switch opened mid-cycle after ignition, commonly from surging condensate in exhaust pipe.

## Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code 272 temporarily or alternates with pressure, flame, or limit switch lockouts.

LennoxCode 154

### [Lennox Code 154 / E250: Primary Limit Open or Airflow Fault](https://myhomeheating.org/error-codes/lennox/code-154-low-ambient-or-pressure/)

LennoxCode 110

### [Lennox Code 110: Low AC Line Voltage (< 90VAC)](https://myhomeheating.org/error-codes/lennox/code-110-low-line-voltage/)

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Lennox #272

### Why does Lennox blink fault code 272?

Lennox Gas Furnace code 272 indicates: Draft switch opened mid-cycle after ignition, commonly from surging condensate in exhaust pipe..

Cadence

### What LED timing marks Lennox code 272?

On Lennox boards, 7-segment LED showing 272 fires 2 slow and 7 fast LED pulses repeatedly.

Check 1

### Which external check applies first to Lennox 272?

First on Lennox code 272: Inspect horizontal PVC exhaust pipe slope if accessible; secondary check: Check outdoor vent end for wind/snow.

Manual Ref

### What does Lennox Diagnostic Codes — 272 document for code 272?

Lennox 272: Draft switch opened mid-cycle after ignition, commonly from surging condensate in exhaust pipe. — recorded under Lennox Diagnostic Codes — 272 for Lennox Gas Furnace equipment.

Pro Fix

### How do techs repair Lennox Gas Furnace fault 272?

Authorized repair on Lennox code 272: Pull condensate drain trap and test inducer vacuum stability during full heat run. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

### Why avoid jumping switches on Lennox code 272?

Combustion safety lockouts block CO or delayed ignition hazards on Lennox code 272.

Reset

### Will flipping the breaker clear Lennox code 272?

One brief power cycle resets transient Lennox code 272, while repeat trips need mechanical testing.

Credentials

### What license applies to Lennox Gas Furnace fault 272?

Licensed mechanical diagnostic credentials apply for Lennox code 272.

## Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

1. [Lennox Residential Public Product & Warranty Documentation](https://www.lennox.com/residential/products/resources/manuals/) — Lennox International (Public Portal), Lennox Public Portal (retrieved 2026-11-23)
2. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

[ All Furnace & Heat Pump Fault Codes → ](https://myhomeheating.org/error-codes/) [ 0-15 Min HVAC Emergency Triage → ](https://myhomeheating.org/emergency/) [ Lennox Code 273: Flame Lost Mid-Cycle → ](https://myhomeheating.org/error-codes/lennox/code-273-flame-lost-during-run/) [ Lennox Code 290: Igniter Relay / Circuit Open → ](https://myhomeheating.org/error-codes/lennox/code-290-igniter-circuit-fault/) [ Lennox Code 310: Rollout Switch Open (Manual Reset) → ](https://myhomeheating.org/error-codes/lennox/code-310-rollout-switch-open/)

Emergency & Parts Links

[Emergency Safety Guides →](https://myhomeheating.org/emergency/) [Verify State-Licensed Techs](https://myhomeheating.org/pros/)