title: "Lennox 241: Flame Sensed Without Heat Call"
url: https://myhomeheating.org/error-codes/lennox/code-241-flame-sensed-no-call/
description: "Lennox Gas Furnace fault 241 (7-segment LED showing 241): pulse timing, safe filter/vent checks, and licensed technician diagnostics."
---

Lennox · Gas Furnace · Fault Code 241

# Lennox Code 241: Flame Sensed Without Heat Call

Control board sensed flame current while the gas valve was supposed to be shut off. Lennox Code 241: Flame Sensed Without Heat Call benchmarks residential systems using Manufacturer Family set at Lennox and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Lennox Code 241: Flame Sensed Without Heat Call across single-family housing. Lennox Diagnostic Codes — 241: Lennox 241: Control board sensed flame current while the gas valve was supposed to be shut off. Pro fix: Inspect flame sensor lead for moisture ground and leak-test gas valve..

- **Manufacturer Family**: Lennox

- **Control System**: Gas Furnace

- **Fault Code**: 241

- **LED Blink Sequence**: 7-segment LED showing 241

- **Slow / Fast Pulses**: 2 slow / 4 fast

- **Control Supply Voltage**: 24 VAC Board / 5 min Breaker Wait

Life-Safety Protocol: Carbon Monoxide, Natural Gas, or Electrical Fire

If a carbon monoxide alarm sounds, you smell natural gas or burning wiring, or a breaker box is sparking: leave the house right away and call **911** or your gas utility emergency line from outside. Do not flip light switches or breaker panels if you smell gas.

## How do you identify fault code 241 on Lennox diagnostic LEDs?

Control board sensed flame current while the gas valve was supposed to be shut off. Lennox Code 241: Flame Sensed Without Heat Call uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.

Pattern: 7-segment LED showing 241

| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| **Slow LED Pulses** | 2 x 520 ms amber (1,600 ms) | First digit / slow code cadence |
| **Fast LED Pulses** | 4 x 200 ms red (1,520 ms) | Second digit / rapid fault pulses |
| **Total Cycle Period** | 4,320 ms | Includes 1,200 ms pause between repeats |
| **External Static Ceiling** | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| **24VAC Control Supply** | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |

## Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

### External Verification Checklist

- Turn thermostat OFF and verify burner is dark through sight glass
- If burner stays lit, shut gas valve and evacuate

Licensed Technician

### Professional Diagnostic Scope

Inspect flame sensor lead for moisture ground and leak-test gas valve.

**Lennox Diagnostic Codes — 241:** Lennox 241: Control board sensed flame current while the gas valve was supposed to be shut off.

## Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code 241 temporarily or alternates with pressure, flame, or limit switch lockouts.

LennoxCode 154

### [Lennox Code 154 / E250: Primary Limit Open or Airflow Fault](https://myhomeheating.org/error-codes/lennox/code-154-low-ambient-or-pressure/)

LennoxCode 110

### [Lennox Code 110: Low AC Line Voltage (< 90VAC)](https://myhomeheating.org/error-codes/lennox/code-110-low-line-voltage/)

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Lennox #241

### Why does Lennox blink fault code 241?

Lennox Gas Furnace code 241 indicates: Control board sensed flame current while the gas valve was supposed to be shut off..

Cadence

### What LED timing marks Lennox code 241?

On Lennox boards, 7-segment LED showing 241 fires 2 slow and 4 fast LED pulses repeatedly.

Check 1

### Which external check applies first to Lennox 241?

First on Lennox code 241: Turn thermostat OFF and verify burner is dark through sight glass; secondary check: If burner stays lit, shut gas valve and evacuate.

Manual Ref

### What does Lennox Diagnostic Codes — 241 document for code 241?

Lennox 241: Control board sensed flame current while the gas valve was supposed to be shut off. — recorded under Lennox Diagnostic Codes — 241 for Lennox Gas Furnace equipment.

Pro Fix

### How do techs repair Lennox Gas Furnace fault 241?

Authorized repair on Lennox code 241: Inspect flame sensor lead for moisture ground and leak-test gas valve. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

### Why avoid jumping switches on Lennox code 241?

Combustion safety lockouts block CO or delayed ignition hazards on Lennox code 241.

Reset

### Will flipping the breaker clear Lennox code 241?

One brief power cycle resets transient Lennox code 241, while repeat trips need mechanical testing.

Credentials

### What license applies to Lennox Gas Furnace fault 241?

Licensed mechanical diagnostic credentials apply for Lennox code 241.

## Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

1. [Lennox Residential Public Product & Warranty Documentation](https://www.lennox.com/residential/products/resources/manuals/) — Lennox International (Public Portal), Lennox Public Portal (retrieved 2026-11-23)
2. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

[ All Furnace & Heat Pump Fault Codes → ](https://myhomeheating.org/error-codes/) [ 0-15 Min HVAC Emergency Triage → ](https://myhomeheating.org/emergency/) [ Lennox Code 250: Primary High-Limit Switch Open → ](https://myhomeheating.org/error-codes/lennox/code-250-primary-limit-open/) [ Lennox Code 270: Flame Failed to Prove (Soft Lockout) → ](https://myhomeheating.org/error-codes/lennox/code-270-soft-ignition-lockout/) [ Lennox Code 272: Pressure Switch Opened During Run → ](https://myhomeheating.org/error-codes/lennox/code-272-pressure-switch-open-run/)

Emergency & Parts Links

[Emergency Safety Guides →](https://myhomeheating.org/emergency/) [Verify State-Licensed Techs](https://myhomeheating.org/pros/)