Draft pressure switch did not close after inducer startup due to condensate clog, cracked hose, or blocked exhaust. Goodman Code E2: Pressure Switch Stuck Open benchmarks residential systems using Manufacturer Family set at Goodman / Daikin / Amana and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Goodman Code E2: Pressure Switch Stuck Open across single-family housing. Goodman Furnace Fault Table — E2: Goodman / Daikin / Amana E2: Draft pressure switch did not close after inducer startup due to condensate clog, cracked hose, or blocked exhaust. Pro fix: Check negative draft vacuum with manometer and clear condensate collector box..

- **Manufacturer Family**: Goodman / Daikin / Amana

- **Control System**: Gas Furnace

- **Fault Code**: E2

- **LED Blink Sequence**: 7-segment display showing E2

- **Slow / Fast Pulses**: 0 slow / 2 fast

- **Control Supply Voltage**: 24 VAC Board / 5 min Breaker Wait

Life-Safety Protocol: Carbon Monoxide, Natural Gas, or Electrical Fire

If a carbon monoxide alarm sounds, you smell natural gas or burning wiring, or a breaker box is sparking: leave the house right away and call **911** or your gas utility emergency line from outside. Do not flip light switches or breaker panels if you smell gas.

## How do you identify fault code E2 on Goodman / Daikin / Amana diagnostic LEDs?

Draft pressure switch did not close after inducer startup due to condensate clog, cracked hose, or blocked exhaust.

Pattern: 7-segment display showing E2

| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| **Fast LED Pulses** | 2 x 200 ms red (760 ms) | Second digit / rapid fault pulses |
| **Total Cycle Period** | 1,960 ms | Includes 1,200 ms pause between repeats |
| **External Static Ceiling** | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| **24VAC Control Supply** | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |

## Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

### External Verification Checklist

- Inspect outdoor PVC exhaust/intake pipes for frost or leaves
- Check condensate drain hose for kinks

Licensed Technician

### Professional Diagnostic Scope

Check negative draft vacuum with manometer and clear condensate collector box.

**Goodman Furnace Fault Table — E2:** Goodman / Daikin / Amana E2: Draft pressure switch did not close after inducer startup due to condensate clog, cracked hose, or blocked exhaust.

## Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code E2 temporarily or alternates with pressure, flame, or limit switch lockouts.

Goodman / Daikin / AmanaCode E5

### [Code E5: Open Fuse or Primary Limit Circuit Open](https://myhomeheating.org/error-codes/goodman/code-e5-open-limit-fuse/)

Goodman / Daikin / AmanaCode EE

### [Code EE / E0: Ignition Lockout or Flame Sense Fault](https://myhomeheating.org/error-codes/goodman/code-ee-ignition-lockout/)

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Goodman / Daikin / Amana #E2

### Why does Goodman / Daikin / Amana blink fault code E2?

Goodman / Daikin / Amana Gas Furnace code E2 indicates: Draft pressure switch did not close after inducer startup due to condensate clog, cracked hose, or blocked exhaust..

Cadence

### What LED timing marks Goodman / Daikin / Amana code E2?

On Goodman / Daikin / Amana boards, 7-segment display showing E2 fires 0 slow and 2 fast LED pulses repeatedly.

Check 1

### Which external check applies first to Goodman / Daikin / Amana E2?

First on Goodman / Daikin / Amana code E2: Inspect outdoor PVC exhaust/intake pipes for frost or leaves; secondary check: Check condensate drain hose for kinks.

Manual Ref

### What does Goodman Furnace Fault Table — E2 document for code E2?

Goodman / Daikin / Amana E2: Draft pressure switch did not close after inducer startup due to condensate clog, cracked hose, or blocked exha — recorded under Goodman Furnace Fault Table — E2 for Goodman / Daikin / Amana Gas Furnace equipment.

Pro Fix

### How do techs repair Goodman / Daikin / Amana Gas Furnace fault E2?

Authorized repair on Goodman / Daikin / Amana code E2: Check negative draft vacuum with manometer and clear condensate collector box. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

### Why avoid jumping switches on Goodman / Daikin / Amana code E2?

Combustion safety lockouts block CO or delayed ignition hazards on Goodman / Daikin / Amana code E2.

Reset

### Will flipping the breaker clear Goodman / Daikin / Amana code E2?

One brief power cycle resets transient Goodman / Daikin / Amana code E2, while repeat trips need mechanical testing.

Credentials

### What license applies to Goodman / Daikin / Amana Gas Furnace fault E2?

Licensed mechanical diagnostic credentials apply for Goodman / Daikin / Amana code E2.

## Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

1. [Goodman / Daikin / Amana Residential Literature Library](https://www.goodmanmfg.com/resources/literature-library) — Daikin Comfort Technologies, Goodman Public Library (retrieved 2026-11-23)
2. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

[ All Furnace & Heat Pump Fault Codes → ](https://myhomeheating.org/error-codes/) [ 0-15 Min HVAC Emergency Triage → ](https://myhomeheating.org/emergency/) [ Goodman Code E3: Pressure Switch Stuck Closed → ](https://myhomeheating.org/error-codes/goodman/code-e3-pressure-switch-closed/) [ Goodman Code E4: Open Rollout or Auxiliary Limit → ](https://myhomeheating.org/error-codes/goodman/code-e4-open-rollout/) [ Goodman Code E6: Flame Sensed With Gas Valve Off → ](https://myhomeheating.org/error-codes/goodman/code-e6-flame-without-gas/)

Emergency & Parts Links

[Emergency Safety Guides →](https://myhomeheating.org/emergency/) [Verify State-Licensed Techs](https://myhomeheating.org/pros/)