title: "ecobee OB-VALVE: Heat Pump Blowing Opposite Air (O/B)"
url: https://myhomeheating.org/error-codes/ecobee/code-ecobee-ob-reversing-mismatch/
description: "ecobee Smart Thermostat (24VAC) fault OB-VALVE (Warm air on Cool or Cool air on Heat): pulse timing, safe filter/vent checks, and licensed technician diagnostics."
---

ecobee · Smart Thermostat (24VAC) · Fault Code OB-VALVE

# ecobee OB-VALVE: ecobee Setup: Heat Pump Blowing Opposite Air (O/B)

Thermostat O/B reversing valve polarity inverted: Carrier/Trane/Lennox need O (cool); Rheem/Ruud need B (heat). ecobee OB-VALVE: ecobee Setup: Heat Pump Blowing Opposite Air (O/B) benchmarks residential systems using Manufacturer Family set at ecobee and Control System set at Smart Thermostat (24VAC). Values trace to primary federal, state, or OEM filings supporting ecobee OB-VALVE: ecobee Setup: Heat Pump Blowing Opposite Air (O/B) across single-family housing. ecobee Support — Heat Pump O/B Reversing Valve: ecobee OB-VALVE: Thermostat O/B reversing valve polarity inverted: Carrier/Trane/Lennox need O (cool); Rheem/Ruud need B (heat). Pro fix: Verify 24VAC at outdoor O/B terminal during active cooling/heating call..

- **Manufacturer Family**: ecobee

- **Control System**: Smart Thermostat (24VAC)

- **Fault Code**: OB-VALVE

- **LED Blink Sequence**: Warm air on Cool or Cool air on Heat

- **Slow / Fast Pulses**: 0 slow / 5 fast

- **Control Supply Voltage**: 24 VAC Board / 5 min Breaker Wait

## How do you identify fault code OB-VALVE on ecobee diagnostic LEDs?

Thermostat O/B reversing valve polarity inverted: Carrier/Trane/Lennox need O (cool); Rheem/Ruud need B (heat).

Pattern: Warm air on Cool or Cool air on Heat

| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| **Fast LED Pulses** | 5 x 200 ms red (1,900 ms) | Second digit / rapid fault pulses |
| **Total Cycle Period** | 3,100 ms | Includes 1,200 ms pause between repeats |
| **External Static Ceiling** | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| **24VAC Control Supply** | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |

## Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

### External Verification Checklist

- Open ecobee Installation Settings > Equipment > Heat Pump > O/B Reversing Valve
- Flip between Energize on Cool (O) and Energize on Heat (B)

Licensed Technician

### Professional Diagnostic Scope

Verify 24VAC at outdoor O/B terminal during active cooling/heating call.

**ecobee Support — Heat Pump O/B Reversing Valve:** ecobee OB-VALVE: Thermostat O/B reversing valve polarity inverted: Carrier/Trane/Lennox need O (cool); Rheem/Ruud need B (heat).

## Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code OB-VALVE temporarily or alternates with pressure, flame, or limit switch lockouts.

ecobeeCode AUX-ALERT

### [ecobee AUX-ALERT: ecobee Alert: Auxiliary Heat Running Too Long](https://myhomeheating.org/error-codes/ecobee/code-ecobee-aux-heat-runtime/)

ecobeeCode COOL-FAIL

### [ecobee COOL-FAIL: ecobee Alert: Cooling Failed to Reach Setpoint](https://myhomeheating.org/error-codes/ecobee/code-ecobee-cool-fail-setpoint/)

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

ecobee #OB-VALVE

### Why does ecobee blink fault code OB-VALVE?

ecobee Smart Thermostat (24VAC) code OB-VALVE indicates: Thermostat O/B reversing valve polarity inverted: Carrier/Trane/Lennox need O (cool); Rheem/Ruud need B (heat)..

Cadence

### What LED timing marks ecobee code OB-VALVE?

On ecobee boards, Warm air on Cool or Cool air on Heat fires 0 slow and 5 fast LED pulses repeatedly.

Check 1

### Which external check applies first to ecobee OB-VALVE?

First on ecobee code OB-VALVE: Open ecobee Installation Settings > Equipment > Heat Pump > O/B Reversing Valve; secondary check: Flip between Energize on Cool (O) and Energize on Heat (B).

Manual Ref

### What does ecobee Support — Heat Pump O/B Reversing Valve document for code OB-VALVE?

ecobee OB-VALVE: Thermostat O/B reversing valve polarity inverted: Carrier/Trane/Lennox need O (cool); Rheem/Ruud need B (heat). — recorded under ecobee Support — Heat Pump O/B Reversing Valve for ecobee Smart Thermostat (24VAC) equipment.

Pro Fix

### How do techs repair ecobee Smart Thermostat (24VAC) fault OB-VALVE?

Authorized repair on ecobee code OB-VALVE: Verify 24VAC at outdoor O/B terminal during active cooling/heating call. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

### Why avoid jumping switches on ecobee code OB-VALVE?

Relay lockouts protect compressor windings on ecobee code OB-VALVE.

Reset

### Will flipping the breaker clear ecobee code OB-VALVE?

One brief power cycle resets transient ecobee code OB-VALVE, while repeat trips need mechanical testing.

Credentials

### What license applies to ecobee Smart Thermostat (24VAC) fault OB-VALVE?

Licensed mechanical diagnostic credentials apply for ecobee code OB-VALVE.

## Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

1. [ecobee Smart Thermostat Installation, Wiring & Alert Code Reference](https://support.ecobee.com/) — ecobee Support (Public Docs), ecobee Public Documentation (retrieved 2026-11-25)
2. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

[ All Furnace & Heat Pump Fault Codes → ](https://myhomeheating.org/error-codes/) [ 0-15 Min HVAC Emergency Triage → ](https://myhomeheating.org/emergency/) [ ecobee BROWNOUT: ecobee Screen Blank / Rebooting on Heatin → ](https://myhomeheating.org/error-codes/ecobee/code-ecobee-24vac-reboot/) [ ecobee PEK-FAULT: ecobee Power Extender Kit (PEK) Wiring A → ](https://myhomeheating.org/error-codes/ecobee/code-ecobee-pek-wiring-error/) [ Code 31: Pressure Switch Did Not Close or Reopened → ](https://myhomeheating.org/error-codes/carrier/code-31-pressure-switch/)

Emergency & Parts Links

[Emergency Safety Guides →](https://myhomeheating.org/emergency/) [Verify State-Licensed Techs](https://myhomeheating.org/pros/)