title: "ecobee BROWNOUT: ecobee Screen Blank / Rebooting on Heating"
url: https://myhomeheating.org/error-codes/ecobee/code-ecobee-24vac-reboot/
description: "ecobee Smart Thermostat (24VAC) fault BROWNOUT (Thermostat blanks out during burner ignition): pulse timing, safe filter/vent checks, and licensed technician."
---

ecobee · Smart Thermostat (24VAC) · Fault Code BROWNOUT

# ecobee BROWNOUT: ecobee Screen Blank / Rebooting on Heating Call

Furnace high-temperature limit switch cutting 24VAC power to R/C, or loose C-wire / PEK splice. ecobee BROWNOUT: ecobee Screen Blank / Rebooting on Heating Call benchmarks residential systems using Manufacturer Family set at ecobee and Control System set at Smart Thermostat (24VAC). Values trace to primary federal, state, or OEM filings supporting ecobee BROWNOUT: ecobee Screen Blank / Rebooting on Heating Call across single-family housing. ecobee Support — Thermostat Power Rebooting: ecobee BROWNOUT: Furnace high-temperature limit switch cutting 24VAC power to R/C, or loose C-wire / PEK splice. Pro fix: Measure plenum temperature rise and 24VAC R-to-C stability during burner run..

- **Manufacturer Family**: ecobee

- **Control System**: Smart Thermostat (24VAC)

- **Fault Code**: BROWNOUT

- **LED Blink Sequence**: Thermostat blanks out during burner ignition

- **Slow / Fast Pulses**: 0 slow / 6 fast

- **Control Supply Voltage**: 24 VAC Board / 5 min Breaker Wait

## How do you identify fault code BROWNOUT on ecobee diagnostic LEDs?

Furnace high-temperature limit switch cutting 24VAC power to R/C, or loose C-wire / PEK splice. ecobee BROWNOUT: ecobee Screen Blank / Rebooting on Heating Call uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.

Pattern: Thermostat blanks out during burner ignition

| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| **Fast LED Pulses** | 6 x 200 ms red (2,280 ms) | Second digit / rapid fault pulses |
| **Total Cycle Period** | 3,480 ms | Includes 1,200 ms pause between repeats |
| **External Static Ceiling** | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| **24VAC Control Supply** | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |

## Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

### External Verification Checklist

- Replace dirty furnace air filter immediately
- Check furnace door switch and condensate float switch

Licensed Technician

### Professional Diagnostic Scope

Measure plenum temperature rise and 24VAC R-to-C stability during burner run.

**ecobee Support — Thermostat Power Rebooting:** ecobee BROWNOUT: Furnace high-temperature limit switch cutting 24VAC power to R/C, or loose C-wire / PEK splice.

## Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code BROWNOUT temporarily or alternates with pressure, flame, or limit switch lockouts.

ecobeeCode AUX-ALERT

### [ecobee AUX-ALERT: ecobee Alert: Auxiliary Heat Running Too Long](https://myhomeheating.org/error-codes/ecobee/code-ecobee-aux-heat-runtime/)

ecobeeCode COOL-FAIL

### [ecobee COOL-FAIL: ecobee Alert: Cooling Failed to Reach Setpoint](https://myhomeheating.org/error-codes/ecobee/code-ecobee-cool-fail-setpoint/)

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

ecobee #BROWNOUT

### Why does ecobee blink fault code BROWNOUT?

ecobee Smart Thermostat (24VAC) code BROWNOUT indicates: Furnace high-temperature limit switch cutting 24VAC power to R/C, or loose C-wire / PEK splice..

Cadence

### What LED timing marks ecobee code BROWNOUT?

On ecobee boards, Thermostat blanks out during burner ignition fires 0 slow and 6 fast LED pulses repeatedly.

Check 1

### Which external check applies first to ecobee BROWNOUT?

First on ecobee code BROWNOUT: Replace dirty furnace air filter immediately; secondary check: Check furnace door switch and condensate float switch.

Manual Ref

### What does ecobee Support — Thermostat Power Rebooting document for code BROWNOUT?

ecobee BROWNOUT: Furnace high-temperature limit switch cutting 24VAC power to R/C, or loose C-wire / PEK splice. — recorded under ecobee Support — Thermostat Power Rebooting for ecobee Smart Thermostat (24VAC) equipment.

Pro Fix

### How do techs repair ecobee Smart Thermostat (24VAC) fault BROWNOUT?

Authorized repair on ecobee code BROWNOUT: Measure plenum temperature rise and 24VAC R-to-C stability during burner run. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

### Why avoid jumping switches on ecobee code BROWNOUT?

Relay lockouts protect compressor windings on ecobee code BROWNOUT.

Reset

### Will flipping the breaker clear ecobee code BROWNOUT?

One brief power cycle resets transient ecobee code BROWNOUT, while repeat trips need mechanical testing.

Credentials

### What license applies to ecobee Smart Thermostat (24VAC) fault BROWNOUT?

Licensed mechanical diagnostic credentials apply for ecobee code BROWNOUT.

## Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

1. [ecobee Smart Thermostat Installation, Wiring & Alert Code Reference](https://support.ecobee.com/) — ecobee Support (Public Docs), ecobee Public Documentation (retrieved 2026-11-25)
2. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

[ All Furnace & Heat Pump Fault Codes → ](https://myhomeheating.org/error-codes/) [ 0-15 Min HVAC Emergency Triage → ](https://myhomeheating.org/emergency/) [ ecobee PEK-FAULT: ecobee Power Extender Kit (PEK) Wiring A → ](https://myhomeheating.org/error-codes/ecobee/code-ecobee-pek-wiring-error/) [ Code 31: Pressure Switch Did Not Close or Reopened → ](https://myhomeheating.org/error-codes/carrier/code-31-pressure-switch/) [ Code 33: Limit Circuit Fault (High-Temp Cutoff) → ](https://myhomeheating.org/error-codes/carrier/code-33-limit-circuit-fault/)

Emergency & Parts Links

[Emergency Safety Guides →](https://myhomeheating.org/emergency/) [Verify State-Licensed Techs](https://myhomeheating.org/pros/)