title: "Carrier / Bryant / Payne 24: Secondary 24VAC Fuse Open (3A /"
url: https://myhomeheating.org/error-codes/carrier/code-24-secondary-voltage-fuse-open/
description: "Carrier / Bryant / Payne Gas Furnace fault 24 (2 slow amber flashes followed by 4 fast amber flashes): pulse timing, safe filter/vent checks, and licensed."
---

Carrier / Bryant / Payne · Gas Furnace · Fault Code 24

# Secondary 24VAC Fuse Open (3A / 5A)

Low-voltage 3A or 5A ATC blade fuse opened due to a 24VAC short in thermostat cable, outdoor condenser contactor coil, or humidifier wiring. Secondary 24VAC Fuse Open (3A / 5A) benchmarks residential systems using Manufacturer Family set at Carrier / Bryant / Payne and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Secondary 24VAC Fuse Open (3A / 5A) across single-family housing. Carrier Gas Furnace Diagnostic Table — Code 24: Carrier / Bryant / Payne 24: Low-voltage 3A or 5A ATC blade fuse opened due to a 24VAC short in thermostat cable, outdoor condenser contactor coil, or humidifier wiring. Pro fix: Ohm outdoor condenser contactor coil (10-20 ohms healthy) and isolate Y/W/C conductors before installing new fuse..

- **Manufacturer Family**: Carrier / Bryant / Payne

- **Control System**: Gas Furnace

- **Fault Code**: 24

- **LED Blink Sequence**: 2 slow amber flashes followed by 4 fast amber flashes

- **Slow / Fast Pulses**: 2 slow / 4 fast

- **Control Supply Voltage**: 24 VAC Board / 5 min Breaker Wait

Life-Safety Protocol: Carbon Monoxide, Natural Gas, or Electrical Fire

If a carbon monoxide alarm sounds, you smell natural gas or burning wiring, or a breaker box is sparking: leave the house right away and call **911** or your gas utility emergency line from outside. Do not flip light switches or breaker panels if you smell gas.

## How do you identify fault code 24 on Carrier / Bryant / Payne diagnostic LEDs?

Low-voltage 3A or 5A ATC blade fuse opened due to a 24VAC short in thermostat cable, outdoor condenser contactor coil, or humidifier wiring.

Pattern: 2 slow amber flashes followed by 4 fast amber flashes

| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| **Slow LED Pulses** | 2 x 520 ms amber (1,600 ms) | First digit / slow code cadence |
| **Fast LED Pulses** | 4 x 200 ms red (1,520 ms) | Second digit / rapid fault pulses |
| **Total Cycle Period** | 4,320 ms | Includes 1,200 ms pause between repeats |
| **External Static Ceiling** | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| **24VAC Control Supply** | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |

## Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

### External Verification Checklist

- Inspect outdoor thermostat cable near condenser for trimmer/weed-whacker damage
- Turn thermostat OFF before service

Licensed Technician

### Professional Diagnostic Scope

Ohm outdoor condenser contactor coil (10-20 ohms healthy) and isolate Y/W/C conductors before installing new fuse.

**Carrier Gas Furnace Diagnostic Table — Code 24:** Carrier / Bryant / Payne 24: Low-voltage 3A or 5A ATC blade fuse opened due to a 24VAC short in thermostat cable, outdoor condenser contactor coil, or humidifier wiring.

## Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code 24 temporarily or alternates with pressure, flame, or limit switch lockouts.

Carrier / Bryant / PayneCode 31

### [Code 31: Pressure Switch Did Not Close or Reopened](https://myhomeheating.org/error-codes/carrier/code-31-pressure-switch/)

Carrier / Bryant / PayneCode 33

### [Code 33: Limit Circuit Fault (High-Temp Cutoff)](https://myhomeheating.org/error-codes/carrier/code-33-limit-circuit-fault/)

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Carrier / Bryant / Payne #24

### Why does Carrier / Bryant / Payne blink fault code 24?

Carrier / Bryant / Payne Gas Furnace code 24 indicates: Low-voltage 3A or 5A ATC blade fuse opened due to a 24VAC short in thermostat cable, outdoor condenser contactor coil, or humidifi.

Cadence

### What LED timing marks Carrier / Bryant / Payne code 24?

On Carrier / Bryant / Payne boards, 2 slow amber flashes followed by 4 fast amber flashes fires 2 slow and 4 fast LED pulses repeatedly.

Check 1

### Which external check applies first to Carrier / Bryant / Payne 24?

First on Carrier / Bryant / Payne code 24: Inspect outdoor thermostat cable near condenser for trimmer/weed-whacker damage; secondary check: Turn thermostat OFF before service.

Manual Ref

### What does Carrier Gas Furnace Diagnostic Table — Code 24 document for code 24?

Carrier / Bryant / Payne 24: Low-voltage 3A or 5A ATC blade fuse opened due to a 24VAC short in thermostat cable, outdoor condenser contacto — recorded under Carrier Gas Furnace Diagnostic Table — Code 24 for Carrier / Bryant / Payne Gas Furnace equipment.

Pro Fix

### How do techs repair Carrier / Bryant / Payne Gas Furnace fault 24?

Authorized repair on Carrier / Bryant / Payne code 24: Ohm outdoor condenser contactor coil (10-20 ohms healthy) and isolate Y/W/C conductors before installing new fuse. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

### Why avoid jumping switches on Carrier / Bryant / Payne code 24?

Combustion safety lockouts block CO or delayed ignition hazards on Carrier / Bryant / Payne code 24.

Reset

### Will flipping the breaker clear Carrier / Bryant / Payne code 24?

One brief power cycle resets transient Carrier / Bryant / Payne code 24, while repeat trips need mechanical testing.

Credentials

### What license applies to Carrier / Bryant / Payne Gas Furnace fault 24?

Licensed mechanical diagnostic credentials apply for Carrier / Bryant / Payne code 24.

## Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

1. [Carrier / Bryant / ICP Public Gas Furnace & Heat Pump Installation Literature](https://www.carrier.com/residential/en/us/products/furnaces/) — Carrier Global (Public Docs), Carrier Residential Public Manuals (retrieved 2026-11-23)
2. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

[ All Furnace & Heat Pump Fault Codes → ](https://myhomeheating.org/error-codes/) [ 0-15 Min HVAC Emergency Triage → ](https://myhomeheating.org/emergency/) [ Carrier / Bryant / Payne 32: Low-Stage Pressure Switch Did → ](https://myhomeheating.org/error-codes/carrier/code-32-low-heat-pressure-switch/) [ Carrier / Bryant / Payne 41: Indoor Blower Motor RPM / Fee → ](https://myhomeheating.org/error-codes/carrier/code-41-blower-motor-fault/) [ Carrier / Bryant / Payne 42: Inducer Motor RPM / Hall Sens → ](https://myhomeheating.org/error-codes/carrier/code-42-inducer-motor-fault/)

Emergency & Parts Links

[Emergency Safety Guides →](https://myhomeheating.org/emergency/) [Verify State-Licensed Techs](https://myhomeheating.org/pros/)