title: "Carrier / Bryant / Payne 23: Pressure Switch Did Not Open"
url: https://myhomeheating.org/error-codes/carrier/code-23-pressure-switch-stuck-closed/
description: "Carrier / Bryant / Payne Gas Furnace fault 23 (2 slow amber flashes followed by 3 fast amber flashes): pulse timing, safe filter/vent checks, and licensed."
---

Carrier / Bryant / Payne · Gas Furnace · Fault Code 23

# Carrier / Bryant / Payne 23: Pressure Switch Did Not Open Before Purge

Draft pressure switch contacts read closed prior to energizing the inducer motor, caused by welded contacts or water-locked diaphragm. Carrier / Bryant / Payne 23: Pressure Switch Did Not Open Before Purge benchmarks residential systems using Manufacturer Family set at Carrier / Bryant / Payne and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Carrier / Bryant / Payne 23: Pressure Switch Did Not Open Before Purge across single-family housing. Carrier Gas Furnace Diagnostic Table — Code 23: Carrier / Bryant / Payne 23: Draft pressure switch contacts read closed prior to energizing the inducer motor, caused by welded contacts or water-locked diaphragm. Pro fix: Verify open continuity across pressure switch terminals with inducer off and inspect condensate collector box..

- **Manufacturer Family**: Carrier / Bryant / Payne

- **Control System**: Gas Furnace

- **Fault Code**: 23

- **LED Blink Sequence**: 2 slow amber flashes followed by 3 fast amber flashes

- **Slow / Fast Pulses**: 2 slow / 3 fast

- **Control Supply Voltage**: 24 VAC Board / 5 min Breaker Wait

Life-Safety Protocol: Carbon Monoxide, Natural Gas, or Electrical Fire

If a carbon monoxide alarm sounds, you smell natural gas or burning wiring, or a breaker box is sparking: leave the house right away and call **911** or your gas utility emergency line from outside. Do not flip light switches or breaker panels if you smell gas.

## How do you identify fault code 23 on Carrier / Bryant / Payne diagnostic LEDs?

Draft pressure switch contacts read closed prior to energizing the inducer motor, caused by welded contacts or water-locked diaphragm.

Pattern: 2 slow amber flashes followed by 3 fast amber flashes

| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| **Slow LED Pulses** | 2 x 520 ms amber (1,600 ms) | First digit / slow code cadence |
| **Fast LED Pulses** | 3 x 200 ms red (1,140 ms) | Second digit / rapid fault pulses |
| **Total Cycle Period** | 3,940 ms | Includes 1,200 ms pause between repeats |
| **External Static Ceiling** | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| **24VAC Control Supply** | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |

## Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

### External Verification Checklist

- Check outdoor vent pipes for standing condensation
- Do not tap or bypass the pressure switch housing

Licensed Technician

### Professional Diagnostic Scope

Verify open continuity across pressure switch terminals with inducer off and inspect condensate collector box.

**Carrier Gas Furnace Diagnostic Table — Code 23:** Carrier / Bryant / Payne 23: Draft pressure switch contacts read closed prior to energizing the inducer motor, caused by welded contacts or water-locked diaphragm.

## Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code 23 temporarily or alternates with pressure, flame, or limit switch lockouts.

Carrier / Bryant / PayneCode 31

### [Code 31: Pressure Switch Did Not Close or Reopened](https://myhomeheating.org/error-codes/carrier/code-31-pressure-switch/)

Carrier / Bryant / PayneCode 33

### [Code 33: Limit Circuit Fault (High-Temp Cutoff)](https://myhomeheating.org/error-codes/carrier/code-33-limit-circuit-fault/)

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Carrier / Bryant / Payne #23

### Why does Carrier / Bryant / Payne blink fault code 23?

Carrier / Bryant / Payne Gas Furnace code 23 indicates: Draft pressure switch contacts read closed prior to energizing the inducer motor, caused by welded contacts or water-locked diaphr.

Cadence

### What LED timing marks Carrier / Bryant / Payne code 23?

On Carrier / Bryant / Payne boards, 2 slow amber flashes followed by 3 fast amber flashes fires 2 slow and 3 fast LED pulses repeatedly.

Check 1

### Which external check applies first to Carrier / Bryant / Payne 23?

First on Carrier / Bryant / Payne code 23: Check outdoor vent pipes for standing condensation; secondary check: Do not tap or bypass the pressure switch housing.

Manual Ref

### What does Carrier Gas Furnace Diagnostic Table — Code 23 document for code 23?

Carrier / Bryant / Payne 23: Draft pressure switch contacts read closed prior to energizing the inducer motor, caused by welded contacts or — recorded under Carrier Gas Furnace Diagnostic Table — Code 23 for Carrier / Bryant / Payne Gas Furnace equipment.

Pro Fix

### How do techs repair Carrier / Bryant / Payne Gas Furnace fault 23?

Authorized repair on Carrier / Bryant / Payne code 23: Verify open continuity across pressure switch terminals with inducer off and inspect condensate collector box. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

### Why avoid jumping switches on Carrier / Bryant / Payne code 23?

Combustion safety lockouts block CO or delayed ignition hazards on Carrier / Bryant / Payne code 23.

Reset

### Will flipping the breaker clear Carrier / Bryant / Payne code 23?

One brief power cycle resets transient Carrier / Bryant / Payne code 23, while repeat trips need mechanical testing.

Credentials

### What license applies to Carrier / Bryant / Payne Gas Furnace fault 23?

Licensed mechanical diagnostic credentials apply for Carrier / Bryant / Payne code 23.

## Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

1. [Carrier / Bryant / ICP Public Gas Furnace & Heat Pump Installation Literature](https://www.carrier.com/residential/en/us/products/furnaces/) — Carrier Global (Public Docs), Carrier Residential Public Manuals (retrieved 2026-11-23)
2. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

[ All Furnace & Heat Pump Fault Codes → ](https://myhomeheating.org/error-codes/) [ 0-15 Min HVAC Emergency Triage → ](https://myhomeheating.org/emergency/) [ Secondary 24VAC Fuse Open (3A / 5A) → ](https://myhomeheating.org/error-codes/carrier/code-24-secondary-voltage-fuse-open/) [ Carrier / Bryant / Payne 32: Low-Stage Pressure Switch Did → ](https://myhomeheating.org/error-codes/carrier/code-32-low-heat-pressure-switch/) [ Carrier / Bryant / Payne 41: Indoor Blower Motor RPM / Fee → ](https://myhomeheating.org/error-codes/carrier/code-41-blower-motor-fault/)

Emergency & Parts Links

[Emergency Safety Guides →](https://myhomeheating.org/emergency/) [Verify State-Licensed Techs](https://myhomeheating.org/pros/)