Carrier / Bryant / Payne · Gas Furnace · Fault Code 13

# Carrier / Bryant / Payne 13: Limit Circuit Lockout (3-Hour Thermal Hold)

Primary high-temperature limit or manual rollout switch remained open longer than 3 minutes (escalated from Code 33), locking out gas ignition for 3 hours. Carrier / Bryant / Payne 13: Limit Circuit Lockout (3-Hour Thermal Hold) benchmarks residential systems using Manufacturer Family set at Carrier / Bryant / Payne and Control System set at Gas Furnace. Carrier Gas Furnace Diagnostic Table — Code 13: Carrier / Bryant / Payne 13: Primary high-temperature limit or manual rollout switch remained open longer than 3 minutes (escalated from Code 33), locking out gas ignition for 3 hours. Pro fix: Measure total external static pressure (<= 0.50 in. w.c.), inspect heat exchanger for cracks, and verify blower CFM tap..

- **Manufacturer Family**: Carrier / Bryant / Payne

- **Control System**: Gas Furnace

- **Fault Code**: 13

- **LED Blink Sequence**: 1 slow amber flash followed by 3 fast amber flashes

- **Slow / Fast Pulses**: 1 slow / 3 fast

- **Control Supply Voltage**: 24 VAC Board / 5 min Breaker Wait

Life-Safety Protocol: Carbon Monoxide, Natural Gas, or Electrical Fire

If a carbon monoxide alarm sounds, you smell natural gas or burning wiring, or a breaker box is sparking: leave the house right away and call **911** or your gas utility emergency line from outside. Do not flip light switches or breaker panels if you smell gas.

## How do you identify fault code 13 on Carrier / Bryant / Payne diagnostic LEDs?

Primary high-temperature limit or manual rollout switch remained open longer than 3 minutes (escalated from Code 33), locking out gas ignition for 3 hours.

Pattern: 1 slow amber flash followed by 3 fast amber flashes

| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| **Slow LED Pulses** | 1 x 520 ms amber (800 ms) | First digit / slow code cadence |
| **Fast LED Pulses** | 3 x 200 ms red (1,140 ms) | Second digit / rapid fault pulses |
| **Total Cycle Period** | 3,140 ms | Includes 1,200 ms pause between repeats |
| **External Static Ceiling** | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| **24VAC Control Supply** | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |

## Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

### External Verification Checklist

- Replace clogged 1-inch air filter and open all supply/return grilles
- Do NOT repeatedly reset power if rollout switch is tripped

Licensed Technician

### Professional Diagnostic Scope

Measure total external static pressure (<= 0.50 in. w.c.), inspect heat exchanger for cracks, and verify blower CFM tap.

**Carrier Gas Furnace Diagnostic Table — Code 13:** Carrier / Bryant / Payne 13: Primary high-temperature limit or manual rollout switch remained open longer than 3 minutes (escalated from Code 33), locking out gas ignition for 3 hours.

## Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code 13 temporarily or alternates with pressure, flame, or limit switch lockouts.

Carrier / Bryant / PayneCode 31

### [Code 31: Pressure Switch Did Not Close or Reopened](https://myhomeheating.org/error-codes/carrier/code-31-pressure-switch/)

Carrier / Bryant / PayneCode 33

### [Code 33: Limit Circuit Fault (High-Temp Cutoff)](https://myhomeheating.org/error-codes/carrier/code-33-limit-circuit-fault/)

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Carrier / Bryant / Payne #13

### Why does Carrier / Bryant / Payne blink fault code 13?

Carrier / Bryant / Payne Gas Furnace code 13 indicates: Primary high-temperature limit or manual rollout switch remained open longer than 3 minutes (escalated from Code 33), locking out .

Cadence

### What LED timing marks Carrier / Bryant / Payne code 13?

On Carrier / Bryant / Payne boards, 1 slow amber flash followed by 3 fast amber flashes fires 1 slow and 3 fast LED pulses repeatedly.

Check 1

### Which external check applies first to Carrier / Bryant / Payne 13?

First on Carrier / Bryant / Payne code 13: Replace clogged 1-inch air filter and open all supply/return grilles; secondary check: Do NOT repeatedly reset power if rollout switch is tripped.

Manual Ref

### What does Carrier Gas Furnace Diagnostic Table — Code 13 document for code 13?

Carrier / Bryant / Payne 13: Primary high-temperature limit or manual rollout switch remained open longer than 3 minutes (escalated from Cod — recorded under Carrier Gas Furnace Diagnostic Table — Code 13 for Carrier / Bryant / Payne Gas Furnace equipment.

Pro Fix

### How do techs repair Carrier / Bryant / Payne Gas Furnace fault 13?

Authorized repair on Carrier / Bryant / Payne code 13: Measure total external static pressure (<= 0.50 in. w.c.), inspect heat exchanger for cracks, and verify blower CFM tap. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

### Why avoid jumping switches on Carrier / Bryant / Payne code 13?

Combustion safety lockouts block CO or delayed ignition hazards on Carrier / Bryant / Payne code 13.

Reset

### Will flipping the breaker clear Carrier / Bryant / Payne code 13?

One brief power cycle resets transient Carrier / Bryant / Payne code 13, while repeat trips need mechanical testing.

Credentials

### What license applies to Carrier / Bryant / Payne Gas Furnace fault 13?

Licensed mechanical diagnostic credentials apply for Carrier / Bryant / Payne code 13.

## Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

1. [Carrier / Bryant / ICP Public Gas Furnace & Heat Pump Installation Literature](https://www.carrier.com/residential/en/us/products/furnaces/) — Carrier Global (Public Docs), Carrier Residential Public Manuals (retrieved 2026-11-23)
2. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

[ All Furnace & Heat Pump Fault Codes → ](https://myhomeheating.org/error-codes/) [ 0-15 Min HVAC Emergency Triage → ](https://myhomeheating.org/emergency/) [ Carrier / Bryant / Payne 14: Ignition Lockout (4 Missed Tr → ](https://myhomeheating.org/error-codes/carrier/code-14-ignition-lockout/) [ Carrier / Bryant / Payne 21: Gas Heating Lockout (Valve Re → ](https://myhomeheating.org/error-codes/carrier/code-21-gas-heating-lockout/) [ Carrier / Bryant / Payne 22: Abnormal Flame-Proving Signal → ](https://myhomeheating.org/error-codes/carrier/code-22-abnormal-flame-proving/)

Emergency & Parts Links

[Emergency Safety Guides →](https://myhomeheating.org/emergency/) [Verify State-Licensed Techs](https://myhomeheating.org/pros/)