---
title: "TCC TH8321WF**** Specs: 0.17W Standby (#17/116)"
url: https://myhomeheating.org/equipment/smart-thermostats/tcc/tcc-th8321wf/
description: "Verified ENERGY STAR specs for TCC TH8321WF**** smart thermostat: 0.17W Standby, #17 of 116, operating cost formula, and peer models."
---

Smart Thermostat · TCC · 1 ENERGY STAR Combinations

# TCC TH8321WF — Smart Thermostat Specifications

TCC TH8321WF (Smart Thermostat, PD ID 2344252) holds 1 ENERGY STAR certified SKU rated at 0.17W Standby — #17 of 116 (Top 17.2%, 4 tied), -0.43 W. ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. TCC TH8321WF — Smart Thermostat Specifications benchmarks residential systems using Cohort Rank set at #17/116 and Verified Combos set at 1 SKU.

- **Cohort Rank**: #17/116

- **Verified Combos**: 1 SKU

- **Sample PD ID**: 2344252

- **Federal AC Minimum**: 13.4 - 14.3 SEER2

Smart Thermostat Efficiency Spread across 116 certified series (0.0 to 2.6 W)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 0.0 - 0.3 W | 25 | This series |
| 0.3 - 0.6 W | 34 | Peer range |
| 0.6 - 0.9 W | 11 | Peer range |
| 0.9 - 1.2 W | 8 | Peer range |
| 1.2 - 1.5 W | 12 | Peer range |
| 1.5 - 1.7 W | 12 | Peer range |
| 1.7 - 2.0 W | 6 | Peer range |
| 2.0 - 2.3 W | 4 | Peer range |
| 2.3 - 2.6 W | 4 | Peer range |

TCC TH8321WF residential equipment inspection. ThermalSpec Editorial Photography

## How does TCC TH8321WF rank across federal compliance and ENERGY STAR cohorts?

TCC TH8321WF ranks #17 of 116 (tied with 3 others at 0.17 W, top 17.2%, lower standby draw than 82.8% of certified thermostats) for Network Standby (-0.43 W vs 0.60 W category median) across 1 certified SKU combination. Supports Wi-Fi with +/-0.2 F static accuracy and 0.17 W network standby. Zero CPSC residential HVAC recall filings match TCC in ThermalSpec's current SaferProducts feed.

TCC TH8321WF Cohort Metrics vs. Smart Thermostat Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Network Standby)** | #17 of 116 (Top 17.2%, 4 tied) | -0.43 W vs 0.60 W category median |
| **Static Temp Accuracy** | +/-0.2 F | -0.31 F vs 0.51 F median |
| **Idle-to-Standby Timeout** | 44.0 min | ENERGY STAR CT Spec |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **Low Network Standby Power (<= 1.0 W)** | LOW DRAW | Measured 0.17 W average network standby vs 0.6 W category median |
| **Thermostat Static Accuracy (<= 0.5 F)** | HIGH PRECISION | Lab static accuracy +/-0.2 F vs 0.51 F category median |
| **24VAC Common Wire & Control Interfaces** | CONNECTED | Methods: Wi-Fi; check O (Carrier/Trane) vs B (Rheem/Ruud) reversing valve |

## How much annual energy and operating cost does TCC TH8321WF require?

Annual cost outputs combine TCC TH8321WF's 0.17 W rating and EIA national tariffs across single-family runtime hours.

Standby_kWh = (0.17 W * 8,760 hrs) / 1,000 | Standby_USD = Standby_kWh * $0.1633/kWh

Continuous 24/7/365 network standby draw priced at US 51-state median 16.33 c/kWh

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **Continuous Standby Electricity (8,760 hrs)** | 1.49 kWh/yr | $0.24/yr |
| **State Standby Cost Spread** | $0.19 (NV) | to $0.70/yr (HI) |
| **Static Control Band (+/-F)** | +/-0.2 F | Lower band tightens setpoint deadband cycling |

Split Heat Pump Reversing Valve & 24VAC O/B Control Flow

Cooling mode energizes O terminal on Carrier, Trane, Lennox, Goodman, and Bosch; Rheem and Ruud energize B on heating.

## Which AHRI certified SKU combinations belong to TCC TH8321WF?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for TCC TH8321WF (PD ID 2344252).

| TH8321WF | Matched AHRI Coil | — |  |
|---|---|---|---|

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on TCC TH8321WF, review 2 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across TCC TH8321WF: headline Network Standby reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for TCC TH8321WF exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal TCC TH8321WF fit** | Single-family replacement needing documented ENERGY STAR PD ID 2344252 with matching indoor air handler. |
| **Skip TCC TH8321WF if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable smart thermostat models deliver similar efficiency?

Compare TCC TH8321WF against Alarm.com TH6320ZW and closely matched smart thermostat units sharing similar Network Standby output and BTU tonnage.

### [Alarm.com TH6320ZW](https://myhomeheating.org/equipment/smart-thermostats/alarm-com/alarm-com-th6320zw/)

0.17 W · +/-0.59 F · Z-Wave

### [Ecobee EB-STATE5*](https://myhomeheating.org/equipment/smart-thermostats/ecobee/ecobee-eb-state5/)

0.17 W · +/-1.01 F · Bluetooth, Wi-Fi, Other

### [Honeywell Home TH6320ZW](https://myhomeheating.org/equipment/smart-thermostats/honeywell-home/honeywell-home-th6320zw/)

0.17 W · +/-0.59 F · Z-Wave

### [Resideo TH8732WFH](https://myhomeheating.org/equipment/smart-thermostats/resideo/resideo-th8732wfh/)

0.18 W · +/-0.37 F · Wi-Fi

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does TCC TH8321WF compare with peer Smart Thermostat units?

TCC TH8321WF holds #17 of 116 (Top 17.2%, 4 tied) out of 116 verified smart thermostat models (-0.43 W vs 0.60 W category median), spanning 1 certified SKU up to 0.17 W standby. Closest same-cohort alternatives include Alarm.com TH6320ZW.

DOE Regions

### Where is TCC TH8321WF compliant for 2026 US installation?

TCC TH8321WF: ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does TCC TH8321WF model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, TCC TH8321WF runs 1.49 kWh/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does TCC TH8321WF cover?

TCC TH8321WF covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does TCC TH8321WF handle extreme weather or cold snaps?

TCC TH8321WF delivers steady fuel combustion independent of outdoor air temperature.

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern TCC TH8321WF?

TCC TH8321WF specifies sealed combustion compliance (PD ID 2344252); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 1 certified SKU in TCC TH8321WF reach 0.17 W standby?

Peak 0.17 W standby represents the top tested AHRI pairing for TCC TH8321WF (PD ID 2344252); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to TCC TH8321WF?

TCC TH8321WF requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Alarm.com TH6320ZW.

## Sources

Verified numerical figures and rules trace to the 3 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Smart Thermostats Dataset (7p2p-wkbf)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Smart-Thermostats/7p2p-wkbf) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
3. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

[ All TCC Smart Thermostats (6) → ](https://myhomeheating.org/equipment/smart-thermostats/tcc/) [ All Smart Thermostats (116) → ](https://myhomeheating.org/equipment/smart-thermostats/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare Alarm.com TH6320ZW (0.17 W) → ](https://myhomeheating.org/equipment/smart-thermostats/alarm-com/alarm-com-th6320zw/) [ Compare Ecobee EB-STATE5* (0.17 W) → ](https://myhomeheating.org/equipment/smart-thermostats/ecobee/ecobee-eb-state5/) [ TCC TH9320WF → ](https://myhomeheating.org/equipment/smart-thermostats/tcc/tcc-th9320wf/) [ TCC THX9421R → ](https://myhomeheating.org/equipment/smart-thermostats/tcc/tcc-thx9421r/) [ tekmar 564 → ](https://myhomeheating.org/equipment/smart-thermostats/tekmar/tekmar-564/)

TCC Quick Spec Summary

- **Cohort Rank**: #17/116

- **Network Standby**: top 17.2%, 4 tied

- **Verified SKUs**: 1

- **Brand Hub**: [TCC](https://myhomeheating.org/equipment/smart-thermostats/tcc/)

- **Category Hub**: [Smart Thermostat](https://myhomeheating.org/equipment/smart-thermostats/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).
