title: "Fisrt Alert RCHT9*10WF**** Specs: 1.65W Standby (#94/116)"
url: https://myhomeheating.org/equipment/smart-thermostats/fisrt-alert/fisrt-alert-rcht9-10wf/
description: "Verified ENERGY STAR specs for Fisrt Alert RCHT9*10WF**** smart thermostat: 1.65W Standby, #94 of 116, operating cost formula, and peer models."
---

Smart Thermostat · Fisrt Alert · 1 ENERGY STAR Combinations

# Fisrt Alert RCHT9*10WF — Smart Thermostat Specifications

Fisrt Alert RCHT9*10WF (Smart Thermostat, PD ID 4515877) holds 1 ENERGY STAR certified SKU rated at 1.65W Standby — #94 of 116 (9 tied, lower than 12.1% of peers), +1.05 W. ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. Fisrt Alert RCHT9*10WF — Smart Thermostat Specifications benchmarks residential systems using Cohort Rank set at #94/116 and Verified Combos set at 1 SKU.

- **Cohort Rank**: #94/116

- **Verified Combos**: 1 SKU

- **Sample PD ID**: 4515877

- **Federal AC Minimum**: 13.4 - 14.3 SEER2

Smart Thermostat Efficiency Spread across 116 certified series (0.0 to 2.6 W)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 0.0 - 0.3 W | 25 | Peer range |
| 0.3 - 0.6 W | 34 | Peer range |
| 0.6 - 0.9 W | 11 | Peer range |
| 0.9 - 1.2 W | 8 | Peer range |
| 1.2 - 1.5 W | 12 | Peer range |
| 1.5 - 1.7 W | 12 | This series |
| 1.7 - 2.0 W | 6 | Peer range |
| 2.0 - 2.3 W | 4 | Peer range |
| 2.3 - 2.6 W | 4 | Peer range |

Fisrt Alert RCHT9*10WF residential equipment inspection. ThermalSpec Editorial Photography

## How does Fisrt Alert RCHT9*10WF rank across federal compliance and ENERGY STAR cohorts?

Fisrt Alert RCHT9*10WF ranks #94 of 116 (tied with 8 others at 1.65 W, lower standby draw than 12.1% of certified thermostats) for Network Standby (+1.05 W vs 0.60 W category median) across 1 certified SKU combination. Supports Other, Wi-Fi with +/-0.35 F static accuracy and 1.65 W network standby. Zero CPSC residential HVAC recall filings match Fisrt Alert in ThermalSpec's current SaferProducts feed.

Fisrt Alert RCHT9*10WF Cohort Metrics vs. Smart Thermostat Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Network Standby)** | #94 of 116 (9 tied, lower than 12.1% of peers) | +1.05 W vs 0.60 W category median |
| **Static Temp Accuracy** | +/-0.35 F | -0.16 F vs 0.51 F median |
| **Idle-to-Standby Timeout** | 45.0 min | ENERGY STAR CT Spec |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **Low Network Standby Power (<= 1.0 W)** | STANDARD DRAW | Measured 1.65 W average network standby vs 0.6 W category median |
| **Thermostat Static Accuracy (<= 0.5 F)** | HIGH PRECISION | Lab static accuracy +/-0.35 F vs 0.51 F category median |
| **24VAC Common Wire & Control Interfaces** | CONNECTED | Methods: Other, Wi-Fi; check O (Carrier/Trane) vs B (Rheem/Ruud) reversing valve |

## How much annual energy and operating cost does Fisrt Alert RCHT9*10WF require?

Modeled utility figures for Fisrt Alert RCHT9*10WF (Fisrt Alert) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Network Standby ratings.

Standby_kWh = (1.65 W * 8,760 hrs) / 1,000 | Standby_USD = Standby_kWh * $0.1633/kWh

Continuous 24/7/365 network standby draw priced at US 51-state median 16.33 c/kWh

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **Continuous Standby Electricity (8,760 hrs)** | 14.45 kWh/yr | $2.36/yr |
| **State Standby Cost Spread** | $1.84 (NV) | to $6.82/yr (HI) |
| **Static Control Band (+/-F)** | +/-0.35 F | Lower band tightens setpoint deadband cycling |

Split Heat Pump Reversing Valve & 24VAC O/B Control Flow

Cooling mode energizes O terminal on Carrier, Trane, Lennox, Goodman, and Bosch; Rheem and Ruud energize B on heating.

## Which AHRI certified SKU combinations belong to Fisrt Alert RCHT9*10WF?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Fisrt Alert RCHT9*10WF (PD ID 4515877).

| RCHT9*10WF | Matched AHRI Coil | — |  |
|---|---|---|---|

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Fisrt Alert RCHT9*10WF, review 2 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across Fisrt Alert RCHT9*10WF: headline Network Standby reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Fisrt Alert RCHT9*10WF exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal Fisrt Alert RCHT9*10WF fit** | Single-family replacement needing documented ENERGY STAR PD ID 4515877 with matching indoor air handler. |
| **Skip Fisrt Alert RCHT9*10WF if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable smart thermostat models deliver similar efficiency?

Compare Fisrt Alert RCHT9*10WF against First Alert RCHT9*10WF and closely matched smart thermostat units sharing similar Network Standby output and BTU tonnage.

### [First Alert RCHT9*10WF](https://myhomeheating.org/equipment/smart-thermostats/first-alert/first-alert-rcht9-10wf/)

1.65 W · +/-0.35 F · Other, Wi-Fi

### [First Alert TH6320WF](https://myhomeheating.org/equipment/smart-thermostats/first-alert/first-alert-th6320wf/)

1.65 W · +/-0.35 F · Other, Wi-Fi

### [First Alert THX***WF**](https://myhomeheating.org/equipment/smart-thermostats/first-alert/first-alert-thx-wf/)

1.65 W · +/-0.35 F · Other, Wi-Fi

### [Honeywell Home TH6320WF](https://myhomeheating.org/equipment/smart-thermostats/honeywell-home/honeywell-home-th6320wf/)

1.65 W · +/-0.35 F · Other, Wi-Fi

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does Fisrt Alert RCHT9*10WF compare with peer Smart Thermostat units?

Fisrt Alert RCHT9*10WF holds #94 of 116 (9 tied, lower than 12.1% of peers) out of 116 verified smart thermostat models (+1.05 W vs 0.60 W category median), spanning 1 certified SKU up to 1.65 W standby. Closest same-cohort alternatives include First Alert RCHT9*10WF.

DOE Regions

### Where is Fisrt Alert RCHT9*10WF compliant for 2026 US installation?

Fisrt Alert RCHT9*10WF: ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does Fisrt Alert RCHT9*10WF model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Fisrt Alert RCHT9*10WF runs 14.45 kWh/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does Fisrt Alert RCHT9*10WF cover?

Fisrt Alert RCHT9*10WF covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does Fisrt Alert RCHT9*10WF handle extreme weather or cold snaps?

Fisrt Alert RCHT9*10WF delivers steady fuel combustion independent of outdoor air temperature.

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern Fisrt Alert RCHT9*10WF?

Fisrt Alert RCHT9*10WF specifies sealed combustion compliance (PD ID 4515877); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 1 certified SKU in Fisrt Alert RCHT9*10WF reach 1.65 W standby?

Peak 1.65 W standby represents the top tested AHRI pairing for Fisrt Alert RCHT9*10WF (PD ID 4515877); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to Fisrt Alert RCHT9*10WF?

Fisrt Alert RCHT9*10WF requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include First Alert RCHT9*10WF.

## Sources

Verified numerical figures and rules trace to the 3 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Smart Thermostats Dataset (7p2p-wkbf)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Smart-Thermostats/7p2p-wkbf) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
3. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

[ All Fisrt Alert Smart Thermostats (1) → ](https://myhomeheating.org/equipment/smart-thermostats/fisrt-alert/) [ All Smart Thermostats (116) → ](https://myhomeheating.org/equipment/smart-thermostats/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare First Alert RCHT9*10WF (1.65 W) → ](https://myhomeheating.org/equipment/smart-thermostats/first-alert/first-alert-rcht9-10wf/) [ Compare First Alert TH6320WF (1.65 W) → ](https://myhomeheating.org/equipment/smart-thermostats/first-alert/first-alert-th6320wf/) [ GE 93129894 → ](https://myhomeheating.org/equipment/smart-thermostats/ge/ge-93129894/) [ GE 93130061 → ](https://myhomeheating.org/equipment/smart-thermostats/ge/ge-93130061/) [ Google Nest GA0####-** → ](https://myhomeheating.org/equipment/smart-thermostats/google-nest/google-nest-ga0/)

Fisrt Alert Quick Spec Summary

- **Cohort Rank**: #94/116

- **Network Standby**: 9 tied, lower standby draw than 12.1% of certified thermostats

- **Verified SKUs**: 1

- **Brand Hub**: [Fisrt Alert](https://myhomeheating.org/equipment/smart-thermostats/fisrt-alert/)

- **Category Hub**: [Smart Thermostat](https://myhomeheating.org/equipment/smart-thermostats/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).