title: "Richmond RMV12A10A Specs: 15.0 CEER (#185/589)"
url: https://myhomeheating.org/equipment/room-air-conditioners/richmond/richmond-rmv12a10a/
description: "Verified ENERGY STAR specs for Richmond RMV12A10A room air conditioner: 15.0 CEER, #185 of 589, operating cost formula, and peer models."
---

Room Air Conditioner · Richmond · 1 ENERGY STAR Combinations

# Richmond RMV12A10A — Room Air Conditioner Specifications

Richmond RMV12A10A (Room Air Conditioner, PD ID 3360725) holds 1 ENERGY STAR certified SKU rated at 15.0 CEER — #185 of 589 (195 tied at median), Equal to 15.0 CEER category median. ENERGY STAR certified room air conditioner (15.0 CEER). Richmond RMV12A10A — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 15.0 CEER and Cohort Rank set at #185/589.

- **Cooling CEER**: 15.0 CEER

- **Cohort Rank**: #185/589

- **Verified Combos**: 1 SKU

- **Sample PD ID**: 3360725

Room Air Conditioner Efficiency Spread across 589 certified series (12.0 to 17.6 CEER)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 12.0 - 12.6 CEER | 5 | Peer range |
| 12.6 - 13.2 CEER | 14 | Peer range |
| 13.2 - 13.9 CEER | 78 | Peer range |
| 13.9 - 14.5 CEER | 96 | Peer range |
| 14.5 - 15.1 CEER | 233 | This series |
| 15.1 - 15.7 CEER | 13 | Peer range |
| 15.7 - 16.4 CEER | 140 | Peer range |
| 16.4 - 17.0 CEER | 2 | Peer range |
| 17.0 - 17.6 CEER | 8 | Peer range |

Richmond RMV12A10A residential equipment inspection. ThermalSpec Editorial Photography

## How does Richmond RMV12A10A rank across federal compliance and ENERGY STAR cohorts?

Richmond RMV12A10A ranks #185 of 589 (tied with 194 others at 15.0 CEER, more efficient than 35.7% of certified series) for Max CEER (Equal to 15.0 CEER category median) across 1 certified SKU combination. Does Not Straddle Window or Windowsill 115V chassis (1.0 nominal Tons at 12,000 BTU/h) drawing 600.0 kWh/yr (38% less energy than federal baseline).

Richmond RMV12A10A Cohort Metrics vs. Room Air Conditioner Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Max CEER)** | #185 of 589 (195 tied at median) | Equal to 15.0 CEER category median |
| **Energy Margin vs Federal Std** | 38% less kWh | -1.0% vs 39% median |
| **DOE Annual Test Energy** | 600.0 kWh/yr | +68.1 kWh vs 531.9 kWh median |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **2026 Cleaner Refrigerant Rule** | COMPLIANT A2L | Uses R-32 (cleaner low-warming refrigerant standard) |
| **Electrical Supply Circuit** | 115V | Standard 15A/20A 115V household receptacle |
| **Variable-Speed Inverter Compressor** | INVERTER | Variable-Speed |

## How much annual energy and operating cost does Richmond RMV12A10A require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Richmond RMV12A10A estimates reflect 1 certified SKU combination tested under PD ID 3360725.

Annual_USD = 600.0 kWh/yr (EPA 750-hr test) * $/kWh | Fed_Baseline_kWh = 600.0 / (1 - 0.38)

EPA ENERGY STAR annual kWh test basis at US median 16.33 c/kWh

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **EPA Rated Annual Energy Consumption** | 600.0 kWh/yr | $97.98/yr at US median |
| **State Operating Cost Spread** | $76.32 (NV) | to $283.08/yr (HI) |
| **Energy Saved vs US Federal Baseline** | 367.7 kWh/yr (38%) | $60.05/yr saved |

UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

## Which AHRI certified SKU combinations belong to Richmond RMV12A10A?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Richmond RMV12A10A (PD ID 3360725).

| RMV12A10A | Matched AHRI Coil | 12,000 BTU/h |  |
|---|---|---|---|

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Richmond RMV12A10A, review 2 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across Richmond RMV12A10A: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Richmond RMV12A10A exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal Richmond RMV12A10A fit** | Single-family replacement needing documented ENERGY STAR PD ID 3360725 with matching indoor air handler. |
| **Skip Richmond RMV12A10A if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable room air conditioner models deliver similar efficiency?

Compare Richmond RMV12A10A against Frigidaire Gallery GHWW125TE1 and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.

### [Frigidaire Gallery GHWW125TE1](https://myhomeheating.org/equipment/room-air-conditioners/frigidaire-gallery/frigidaire-gallery-ghww125te1/)

15.0 CEER · 38% less kWh · 12,000 BTU/h

### [GE Profile PWDV12W**#](https://myhomeheating.org/equipment/room-air-conditioners/ge-profile/ge-profile-pwdv12w/)

15.0 CEER · 38% less kWh · 12,000 BTU/h

### [Hisense 143-1306-8](https://myhomeheating.org/equipment/room-air-conditioners/hisense/hisense-143-1306-8/)

15.0 CEER · 38% less kWh · 12,000 BTU/h

### [Hisense AAW12TW26](https://myhomeheating.org/equipment/room-air-conditioners/hisense/hisense-aaw12tw26/)

15.0 CEER · 38% less kWh · 12,000 BTU/h

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does Richmond RMV12A10A compare with peer Room Air Conditioner units?

Richmond RMV12A10A holds #185 of 589 (195 tied at median) out of 589 verified room air conditioner models (Equal to 15.0 CEER category median), spanning 1 certified SKU up to 15.0 CEER. Closest same-cohort alternatives include Frigidaire Gallery GHWW125TE1.

DOE Regions

### Where is Richmond RMV12A10A compliant for 2026 US installation?

Richmond RMV12A10A: ENERGY STAR certified room air conditioner (15.0 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does Richmond RMV12A10A model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Richmond RMV12A10A runs 600.0 kWh/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does Richmond RMV12A10A cover?

Richmond RMV12A10A covers 12,000-12,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does Richmond RMV12A10A handle extreme weather or cold snaps?

Richmond RMV12A10A is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern Richmond RMV12A10A?

Richmond RMV12A10A specifies R-32 compliance (PD ID 3360725); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 1 certified SKU in Richmond RMV12A10A reach 15.0 CEER?

Peak 15.0 CEER represents the top tested AHRI pairing for Richmond RMV12A10A (PD ID 3360725); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to Richmond RMV12A10A?

Richmond RMV12A10A requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Frigidaire Gallery GHWW125TE1.

## Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Room-Air-Conditioners/5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
4. [40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-84) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
5. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
6. [Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

[ All Richmond Room Air Conditioners (3) → ](https://myhomeheating.org/equipment/room-air-conditioners/richmond/) [ All Room Air Conditioners (589) → ](https://myhomeheating.org/equipment/room-air-conditioners/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare Frigidaire Gallery GHWW125TE1 (15.0 CEER) → ](https://myhomeheating.org/equipment/room-air-conditioners/frigidaire-gallery/frigidaire-gallery-ghww125te1/) [ Compare GE Profile PWDV12W**# (15.0 CEER) → ](https://myhomeheating.org/equipment/room-air-conditioners/ge-profile/ge-profile-pwdv12w/) [ ROVSUN RVTIW-08CRD1 → ](https://myhomeheating.org/equipment/room-air-conditioners/rovsun/rovsun-rvtiw-08crd1/) [ ROVSUN RVTIW-10CRD1 → ](https://myhomeheating.org/equipment/room-air-conditioners/rovsun/rovsun-rvtiw-10crd1/) [ ROVSUN RVTIW-12CRD1 → ](https://myhomeheating.org/equipment/room-air-conditioners/rovsun/rovsun-rvtiw-12crd1/)

Richmond Quick Spec Summary

- **Cohort Rank**: #185/589

- **Max CEER**: 195 tied, more efficient than 35.7% of certified series

- **Verified SKUs**: 1

- **Brand Hub**: [Richmond](https://myhomeheating.org/equipment/room-air-conditioners/richmond/)

- **Category Hub**: [Room Air Conditioner](https://myhomeheating.org/equipment/room-air-conditioners/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).