Room Air Conditioner · Midea · 2 ENERGY STAR Combinations

# Midea MAW18R2VWT — Room Air Conditioner Specifications

Midea MAW18R2VWT (Room Air Conditioner, PD ID 3354620) holds 2 ENERGY STAR certified SKUs rated at 15.0 CEER — #185 of 589 (195 tied at median), Equal to 15.0 CEER category median. ENERGY STAR certified room air conditioner (15.0 CEER). Midea MAW18R2VWT — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 15.0 CEER and Cohort Rank set at #185/589.

- **Cooling CEER**: 15.0 CEER

- **Cohort Rank**: #185/589

- **Verified Combos**: 2 SKUs

- **Sample PD ID**: 3354620

Room Air Conditioner Efficiency Spread across 589 certified series (12.0 to 17.6 CEER)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 12.0 - 12.6 CEER | 5 | Peer range |
| 12.6 - 13.2 CEER | 14 | Peer range |
| 13.2 - 13.9 CEER | 78 | Peer range |
| 13.9 - 14.5 CEER | 96 | Peer range |
| 14.5 - 15.1 CEER | 233 | This series |
| 15.1 - 15.7 CEER | 13 | Peer range |
| 15.7 - 16.4 CEER | 140 | Peer range |
| 16.4 - 17.0 CEER | 2 | Peer range |
| 17.0 - 17.6 CEER | 8 | Peer range |

Midea MAW18R2VWT residential equipment inspection. ThermalSpec Editorial Photography

## How does Midea MAW18R2VWT rank across federal compliance and ENERGY STAR cohorts?

Midea MAW18R2VWT ranks #185 of 589 (tied with 194 others at 15.0 CEER, more efficient than 35.7% of certified series) for Max CEER (Equal to 15.0 CEER category median) across 2 certified SKU combinations. Does Not Straddle Window or Windowsill 230V chassis (1.5 nominal Tons at 18,000 BTU/h) drawing 900.0 kWh/yr (40% less energy than federal baseline).

Midea MAW18R2VWT Cohort Metrics vs. Room Air Conditioner Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Max CEER)** | #185 of 589 (195 tied at median) | Equal to 15.0 CEER category median |
| **Energy Margin vs Federal Std** | 40% less kWh | +1.0% vs 39% median |
| **DOE Annual Test Energy** | 900.0 kWh/yr | +368.1 kWh vs 531.9 kWh median |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **2026 Cleaner Refrigerant Rule** | COMPLIANT A2L | Uses R-32 (cleaner low-warming refrigerant standard) |
| **Electrical Supply Circuit** | 230V | Requires dedicated 208/230V NEMA 6-15/6-20 receptacle |
| **Variable-Speed Inverter Compressor** | INVERTER | Variable-Speed |

## How much annual energy and operating cost does Midea MAW18R2VWT require?

Modeled utility figures for Midea MAW18R2VWT (Midea) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max CEER ratings.

Annual_USD = 900.0 kWh/yr (EPA 750-hr test) * $/kWh | Fed_Baseline_kWh = 900.0 / (1 - 0.40)

EPA ENERGY STAR annual kWh test basis at US median 16.33 c/kWh

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **EPA Rated Annual Energy Consumption** | 900.0 kWh/yr | $146.97/yr at US median |
| **State Operating Cost Spread** | $114.48 (NV) | to $424.62/yr (HI) |
| **Energy Saved vs US Federal Baseline** | 600.0 kWh/yr (40%) | $97.98/yr saved |

UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

## Which AHRI certified SKU combinations belong to Midea MAW18R2VWT?

Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for Midea MAW18R2VWT (PD ID 3354620).

| MAW18R2VWT | Matched AHRI Coil | 18,000 BTU/h |  |
|---|---|---|---|
| MAW18R2VWT | Matched AHRI Coil | 18,000 BTU/h |  |

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Midea MAW18R2VWT, review 2 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across Midea MAW18R2VWT: headline Max CEER reflects peak tested matches among 2 SKUs, not lower-rated sizes.
- Catalog specs for Midea MAW18R2VWT exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal Midea MAW18R2VWT fit** | Single-family replacement needing documented ENERGY STAR PD ID 3354620 with matching indoor air handler. |
| **Skip Midea MAW18R2VWT if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable room air conditioner models deliver similar efficiency?

Compare Midea MAW18R2VWT against Frigidaire FHWW185WE2 and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.

### [Frigidaire FHWW185WE2](https://myhomeheating.org/equipment/room-air-conditioners/frigidaire/frigidaire-fhww185we2/)

15.0 CEER · 40% less kWh · 18,000 BTU/h

### [Hisense AW1823TW3W](https://myhomeheating.org/equipment/room-air-conditioners/hisense/hisense-aw1823tw3w/)

15.0 CEER · 40% less kWh · 18,000 BTU/h

### [Keplerx KBRC18RSVE2](https://myhomeheating.org/equipment/room-air-conditioners/keplerx/keplerx-kbrc18rsve2/)

15.0 CEER · 40% less kWh · 18,000 BTU/h

### [Keystone KSTAW182WA](https://myhomeheating.org/equipment/room-air-conditioners/keystone/keystone-kstaw182wa/)

15.0 CEER · 40% less kWh · 18,000 BTU/h

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does Midea MAW18R2VWT compare with peer Room Air Conditioner units?

Midea MAW18R2VWT holds #185 of 589 (195 tied at median) out of 589 verified room air conditioner models (Equal to 15.0 CEER category median), spanning 2 certified SKUs up to 15.0 CEER. Closest same-cohort alternatives include Frigidaire FHWW185WE2.

DOE Regions

### Where is Midea MAW18R2VWT compliant for 2026 US installation?

Midea MAW18R2VWT: ENERGY STAR certified room air conditioner (15.0 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does Midea MAW18R2VWT model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Midea MAW18R2VWT runs 900.0 kWh/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does Midea MAW18R2VWT cover?

Midea MAW18R2VWT covers 18,000-18,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does Midea MAW18R2VWT handle extreme weather or cold snaps?

Midea MAW18R2VWT is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern Midea MAW18R2VWT?

Midea MAW18R2VWT specifies R-32 compliance (PD ID 3354620); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 2 certified SKUs in Midea MAW18R2VWT reach 15.0 CEER?

Peak 15.0 CEER represents the top tested AHRI pairing for Midea MAW18R2VWT (PD ID 3354620); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to Midea MAW18R2VWT?

Midea MAW18R2VWT requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Frigidaire FHWW185WE2.

## Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Room-Air-Conditioners/5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
4. [40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-84) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
5. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
6. [Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

[ All Midea Room Air Conditioners (203) → ](https://myhomeheating.org/equipment/room-air-conditioners/midea/) [ All Room Air Conditioners (589) → ](https://myhomeheating.org/equipment/room-air-conditioners/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare Frigidaire FHWW185WE2 (15.0 CEER) → ](https://myhomeheating.org/equipment/room-air-conditioners/frigidaire/frigidaire-fhww185we2/) [ Compare Hisense AW1823TW3W (15.0 CEER) → ](https://myhomeheating.org/equipment/room-air-conditioners/hisense/hisense-aw1823tw3w/) [ Midea MWCUWA-12CRFN8-BCN10 → ](https://myhomeheating.org/equipment/room-air-conditioners/midea/midea-mwcuwa-12crfn8-bcn10/) [ Noma iQ 143-0087-4 → ](https://myhomeheating.org/equipment/room-air-conditioners/noma-iq/noma-iq-143-0087-4/) [ Noma iQ 143-0088-2 → ](https://myhomeheating.org/equipment/room-air-conditioners/noma-iq/noma-iq-143-0088-2/)

Midea Quick Spec Summary

- **Cohort Rank**: #185/589

- **Max CEER**: 195 tied, more efficient than 35.7% of certified series

- **Verified SKUs**: 2

- **Brand Hub**: [Midea](https://myhomeheating.org/equipment/room-air-conditioners/midea/)

- **Category Hub**: [Room Air Conditioner](https://myhomeheating.org/equipment/room-air-conditioners/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).