---
title: "GE Profile PHNT10CCH1 Specs: 14.7 CEER (#380/589)"
url: https://myhomeheating.org/equipment/room-air-conditioners/ge-profile/ge-profile-phnt10cch1/
description: "Verified ENERGY STAR specs for GE Profile PHNT10CCH1 room air conditioner: 14.7 CEER, #380 of 589, operating cost formula, and peer models."
---

Room Air Conditioner · GE Profile · 1 ENERGY STAR Combinations

# GE Profile PHNT10CCH1 — Room Air Conditioner Specifications

GE Profile PHNT10CCH1 (Room Air Conditioner, PD ID 2684130) holds 1 ENERGY STAR certified SKU rated at 14.7 CEER — #380 of 589 (11 tied, beats 33.8% of peers), -0.30 CEER. ENERGY STAR certified room air conditioner (14.7 CEER). GE Profile PHNT10CCH1 — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 14.7 CEER and Cohort Rank set at #380/589.

- **Cooling CEER**: 14.7 CEER

- **Cohort Rank**: #380/589

- **Verified Combos**: 1 SKU

- **Sample PD ID**: 2684130

Room Air Conditioner Efficiency Spread across 589 certified series (12.0 to 17.6 CEER)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 12.0 - 12.6 CEER | 5 | Peer range |
| 12.6 - 13.2 CEER | 14 | Peer range |
| 13.2 - 13.9 CEER | 78 | Peer range |
| 13.9 - 14.5 CEER | 96 | Peer range |
| 14.5 - 15.1 CEER | 233 | This series |
| 15.1 - 15.7 CEER | 13 | Peer range |
| 15.7 - 16.4 CEER | 140 | Peer range |
| 16.4 - 17.0 CEER | 2 | Peer range |
| 17.0 - 17.6 CEER | 8 | Peer range |

GE Profile PHNT10CCH1 residential equipment inspection. ThermalSpec Editorial Photography

## How does GE Profile PHNT10CCH1 rank across federal compliance and ENERGY STAR cohorts?

GE Profile PHNT10CCH1 ranks #380 of 589 (tied with 10 others at 14.7 CEER, more efficient than 33.8% of certified series) for Max CEER (-0.30 CEER vs 15.0 CEER category median) across 1 certified SKU combination. Straddles Windowsill 115V chassis (0.9 nominal Tons at 10,300 BTU/h) drawing 525.5 kWh/yr (35% less energy than federal baseline).

GE Profile PHNT10CCH1 Cohort Metrics vs. Room Air Conditioner Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Max CEER)** | #380 of 589 (11 tied, beats 33.8% of peers) | -0.30 CEER vs 15.0 CEER category median |
| **Energy Margin vs Federal Std** | 35% less kWh | -4.0% vs 39% median |
| **DOE Annual Test Energy** | 525.5 kWh/yr | -6.4 kWh vs 531.9 kWh median |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **2026 Cleaner Refrigerant Rule** | COMPLIANT A2L | Uses R-32 (cleaner low-warming refrigerant standard) |
| **Electrical Supply Circuit** | 115V | Standard 15A/20A 115V household receptacle |
| **Variable-Speed Inverter Compressor** | INVERTER | Variable-Speed |

## How much annual energy and operating cost does GE Profile PHNT10CCH1 require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, GE Profile PHNT10CCH1 estimates reflect 1 certified SKU combination tested under PD ID 2684130.

Annual_USD = 525.5 kWh/yr (EPA 750-hr test) * $/kWh | Fed_Baseline_kWh = 525.5 / (1 - 0.35)

EPA ENERGY STAR annual kWh test basis at US median 16.33 c/kWh

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **EPA Rated Annual Energy Consumption** | 525.5 kWh/yr | $85.81/yr at US median |
| **State Operating Cost Spread** | $66.84 (NV) | to $247.93/yr (HI) |
| **Energy Saved vs US Federal Baseline** | 283.0 kWh/yr (35%) | $46.21/yr saved |

UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

## Which AHRI certified SKU combinations belong to GE Profile PHNT10CCH1?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for GE Profile PHNT10CCH1 (PD ID 2684130).

| PHNT10CCH1 | Matched AHRI Coil | 10,300 BTU/h |  |
|---|---|---|---|

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on GE Profile PHNT10CCH1, review 2 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across GE Profile PHNT10CCH1: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for GE Profile PHNT10CCH1 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal GE Profile PHNT10CCH1 fit** | Single-family replacement needing documented ENERGY STAR PD ID 2684130 with matching indoor air handler. |
| **Skip GE Profile PHNT10CCH1 if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable room air conditioner models deliver similar efficiency?

Compare GE Profile PHNT10CCH1 against GREE GJC10BU-A6DRNJ2A and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.

### [GREE GJC10BU-A6DRNJ2A](https://myhomeheating.org/equipment/room-air-conditioners/gree/gree-gjc10bu-a6drnj2a/)

14.7 CEER · 35% less kWh · 10,000 BTU/h

### [HOUSE KOBO KOBOGJC10BU](https://myhomeheating.org/equipment/room-air-conditioners/house-kobo/house-kobo-kobogjc10bu/)

14.7 CEER · 35% less kWh · 10,000 BTU/h

### [GREE GJC12BU-A6DRNJ2A](https://myhomeheating.org/equipment/room-air-conditioners/gree/gree-gjc12bu-a6drnj2a/)

14.7 CEER · 35% less kWh · 11,500 BTU/h

### [HOUSE KOBO KOBOGJC12BU](https://myhomeheating.org/equipment/room-air-conditioners/house-kobo/house-kobo-kobogjc12bu/)

14.7 CEER · 35% less kWh · 11,500 BTU/h

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does GE Profile PHNT10CCH1 compare with peer Room Air Conditioner units?

GE Profile PHNT10CCH1 holds #380 of 589 (11 tied, beats 33.8% of peers) out of 589 verified room air conditioner models (-0.30 CEER vs 15.0 CEER category median), spanning 1 certified SKU up to 14.7 CEER. Closest same-cohort alternatives include GREE GJC10BU-A6DRNJ2A.

DOE Regions

### Where is GE Profile PHNT10CCH1 compliant for 2026 US installation?

GE Profile PHNT10CCH1: ENERGY STAR certified room air conditioner (14.7 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does GE Profile PHNT10CCH1 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, GE Profile PHNT10CCH1 runs 525.5 kWh/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does GE Profile PHNT10CCH1 cover?

GE Profile PHNT10CCH1 covers 10,300-10,300 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does GE Profile PHNT10CCH1 handle extreme weather or cold snaps?

GE Profile PHNT10CCH1 is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern GE Profile PHNT10CCH1?

GE Profile PHNT10CCH1 specifies R-32 compliance (PD ID 2684130); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 1 certified SKU in GE Profile PHNT10CCH1 reach 14.7 CEER?

Peak 14.7 CEER represents the top tested AHRI pairing for GE Profile PHNT10CCH1 (PD ID 2684130); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to GE Profile PHNT10CCH1?

GE Profile PHNT10CCH1 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include GREE GJC10BU-A6DRNJ2A.

## Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Room-Air-Conditioners/5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
4. [40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-84) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
5. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
6. [Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 8 pages.

[ All GE Profile Room Air Conditioners (9) → ](https://myhomeheating.org/equipment/room-air-conditioners/ge-profile/) [ All Room Air Conditioners (589) → ](https://myhomeheating.org/equipment/room-air-conditioners/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare GREE GJC10BU-A6DRNJ2A (14.7 CEER) → ](https://myhomeheating.org/equipment/room-air-conditioners/gree/gree-gjc10bu-a6drnj2a/) [ Compare HOUSE KOBO KOBOGJC10BU (14.7 CEER) → ](https://myhomeheating.org/equipment/room-air-conditioners/house-kobo/house-kobo-kobogjc10bu/) [ GE Profile PHNT12CCH1 → ](https://myhomeheating.org/equipment/room-air-conditioners/ge-profile/ge-profile-phnt12cch1/) [ GREE GJC12BU-A6DRNJ2A → ](https://myhomeheating.org/equipment/room-air-conditioners/gree/gree-gjc12bu-a6drnj2a/)

GE Profile Quick Spec Summary

- **Cohort Rank**: #380/589

- **Max CEER**: 11 tied, more efficient than 33.8% of certified series

- **Verified SKUs**: 1

- **Brand Hub**: [GE Profile](https://myhomeheating.org/equipment/room-air-conditioners/ge-profile/)

- **Category Hub**: [Room Air Conditioner](https://myhomeheating.org/equipment/room-air-conditioners/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).
