# MDV M3OJ-27HFN1-M — Mini-Split Heat Pump Specifications

MDV M3OJ-27HFN1-M (Mini-Split Heat Pump, PD ID 2407652) holds 1 ENERGY STAR certified SKU rated at 24.6 SEER2 — #1,391 of 2,096 (90 tied, beats 29.4% of peers), -0.50 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). MDV M3OJ-27HFN1-M — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 24.6 SEER2 and Heating Rating set at 9.5 HSPF2.

- **Max SEER2**: 24.6 SEER2

- **Heating Rating**: 9.5 HSPF2

- **Heating COP**: 2.0 COP

- **Cohort Rank**: #1,391/2,096

- **Verified Combos**: 1 SKU

- **Sample PD ID**: 2407652

Mini-Split Heat Pump Efficiency Spread across 2096 certified series (23.7 to 35.1 SEER2)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | This series |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |

MDV M3OJ-27HFN1-M residential equipment inspection. ThermalSpec Editorial Photography

## How does MDV M3OJ-27HFN1-M rank across federal compliance and ENERGY STAR cohorts?

MDV M3OJ-27HFN1-M ranks #1,391 of 2,096 (tied with 89 others at 24.6 SEER2, more efficient than 29.4% of certified series) for Max SEER2 (-0.50 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Built with Continuously variable modulation (2.3 nominal Tons at 28,000 BTU/h) charged with R-410A. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.

MDV M3OJ-27HFN1-M Cohort Metrics vs. Mini-Split Heat Pump Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Max SEER2)** | #1,391 of 2,096 (90 tied, beats 29.4% of peers) | -0.50 SEER2 vs 25.1 SEER2 category median |
| **Heating HSPF2 vs Cohort** | 9.5 HSPF2 | -1.00 HSPF2 vs 10.5 HSPF2 median |
| **Peak 95F EER2 vs Cohort** | 12.7 EER2 | -1.30 EER2 vs 14.0 EER2 median |
| **5F Cold-Weather Capacity Retention** | 67.9% of 47F rating | 5F COP 2.0 |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **Federal North & SE Heat Pump Minimum** | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 24.6 SEER2 / 9.5 HSPF2 |
| **Southwest Peak-Heat Criterion (AZ/CA/NM/NV)** | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 12.7 EER2 |
| **ENERGY STAR Cold Climate Spec** | STANDARD CLIMATE | Designed for standard/mixed heating zones |
| **2026 Cleaner Refrigerant Rule** | OLDER R-410A | Listed refrigerant: R-410A; newer R-454B/R-32 splits include indoor leak sensors |

## How much annual energy and operating cost does MDV M3OJ-27HFN1-M require?

Annual cost outputs combine MDV M3OJ-27HFN1-M's 24.6 SEER2 rating and EIA national tariffs across single-family runtime hours.

Cool_kWh = (28,000 BTU/h * 1,000 hrs / 24.6 SEER2) / 1,000 | Heat_kWh = 30,000 kBTU / 9.5 HSPF2

Assumes 1,000 cooling hrs + 30 MMBtu heating at US 51-state median 16.33 c/kWh (range 12.72 c NV to 47.18 c HI)

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **Estimated Annual Cooling Energy** | 1,138 kWh/yr | $186/yr at US median |
| **Estimated Annual Heating Energy (30 MMBtu)** | 3,158 kWh/yr | $516/yr at US median |
| **Combined Annual Electricity Cost** | $702/yr | State range: $546 (NV) to $2,027 (HI) |
| **Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor** | 1,662 kWh/yr | $271/yr saved |

UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

## Which AHRI certified SKU combinations belong to MDV M3OJ-27HFN1-M?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for MDV M3OJ-27HFN1-M (PD ID 2407652).

| M3OJ-27HFN1-M | Matched AHRI Coil | 28,000 BTU/h | 24.6 SEER2 / 9.5 HSPF2 |
|---|---|---|---|

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on MDV M3OJ-27HFN1-M, review 3 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across MDV M3OJ-27HFN1-M: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for MDV M3OJ-27HFN1-M exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- MDV M3OJ-27HFN1-M lacks ENERGY STAR Cold Climate 5F designation, so electric heat strips or dual-fuel backup matter in Zones 5-8.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal MDV M3OJ-27HFN1-M fit** | Single-family replacement needing documented ENERGY STAR PD ID 2407652 with matching indoor air handler. |
| **Skip MDV M3OJ-27HFN1-M if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable mini-split heat pump models deliver similar efficiency?

Compare MDV M3OJ-27HFN1-M against 1HVAC ES-27Z-M3B and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.

### [1HVAC ES-27Z-M3B](https://myhomeheating.org/equipment/mini-splits/1hvac/1hvac-es-27z-m3b/)

24.6 SEER2 · 9.5 HSPF2 · 28,000 BTU/h

### [AC PRO A3OJ-27HFN1-M](https://myhomeheating.org/equipment/mini-splits/ac-pro/ac-pro-a3oj-27hfn1-m/)

24.6 SEER2 · 9.5 HSPF2 · 28,000 BTU/h

### [ACIQ ES-27Z-M3B](https://myhomeheating.org/equipment/mini-splits/aciq/aciq-es-27z-m3b/)

24.6 SEER2 · 9.5 HSPF2 · 28,000 BTU/h

### [AIREASE 4DHP2S30M-1P](https://myhomeheating.org/equipment/mini-splits/airease/airease-4dhp2s30m-1p/)

24.6 SEER2 · 9.3 HSPF2 · 28,000 BTU/h

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does MDV M3OJ-27HFN1-M compare with peer Mini-Split Heat Pump units?

MDV M3OJ-27HFN1-M holds #1,391 of 2,096 (90 tied, beats 29.4% of peers) out of 2,096 verified mini-split heat pump models (-0.50 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 24.6 SEER2. Closest same-cohort alternatives include 1HVAC ES-27Z-M3B.

DOE Regions

### Where is MDV M3OJ-27HFN1-M compliant for 2026 US installation?

MDV M3OJ-27HFN1-M: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does MDV M3OJ-27HFN1-M model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, MDV M3OJ-27HFN1-M runs 1,138 kWh/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does MDV M3OJ-27HFN1-M cover?

MDV M3OJ-27HFN1-M covers 28,000-28,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does MDV M3OJ-27HFN1-M handle extreme weather or cold snaps?

MDV M3OJ-27HFN1-M is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern MDV M3OJ-27HFN1-M?

MDV M3OJ-27HFN1-M specifies R-410A compliance (PD ID 2407652); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 1 certified SKU in MDV M3OJ-27HFN1-M reach 24.6 SEER2?

Peak 24.6 SEER2 represents the top tested AHRI pairing for MDV M3OJ-27HFN1-M (PD ID 2407652); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to MDV M3OJ-27HFN1-M?

MDV M3OJ-27HFN1-M requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include 1HVAC ES-27Z-M3B.

## Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Mini-Split-Heat-Pumps/akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
4. [40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-84) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
5. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
6. [Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

[ All MDV Mini-Split Heat Pumps (64) → ](https://myhomeheating.org/equipment/mini-splits/mdv/) [ All Mini-Split Heat Pumps (2,096) → ](https://myhomeheating.org/equipment/mini-splits/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare 1HVAC ES-27Z-M3B (24.6 SEER2) → ](https://myhomeheating.org/equipment/mini-splits/1hvac/1hvac-es-27z-m3b/) [ Compare AC PRO A3OJ-27HFN1-M (24.6 SEER2) → ](https://myhomeheating.org/equipment/mini-splits/ac-pro/ac-pro-a3oj-27hfn1-m/) [ MDV M3OJ-27HFN1-M-L → ](https://myhomeheating.org/equipment/mini-splits/mdv/mdv-m3oj-27hfn1-m-l/) [ MDV MOX230-12HFN1-MV5W-L → ](https://myhomeheating.org/equipment/mini-splits/mdv/mdv-mox230-12hfn1-mv5w-l/) [ Midea MMCMHAQ24CA3 → ](https://myhomeheating.org/equipment/mini-splits/midea/midea-mmcmhaq24ca3/)

MDV Quick Spec Summary

- **Cohort Rank**: #1,391/2,096

- **Max SEER2**: 90 tied, more efficient than 29.4% of certified series

- **Verified SKUs**: 1

- **Brand Hub**: [MDV](https://myhomeheating.org/equipment/mini-splits/mdv/)

- **Category Hub**: [Mini-Split Heat Pump](https://myhomeheating.org/equipment/mini-splits/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).