---
title: "LPS Legacy Mini-Split Heat Pumps: 24 ENERGY STAR Models"
url: https://myhomeheating.org/equipment/mini-splits/lps-legacy/
description: "Browse 24 ENERGY STAR certified LPS Legacy mini-split heat pumps models reaching 33.1 SEER2 across 35 AHRI matched combinations."
---

LPS Legacy | Mini-Split Heat Pumps

# LPS Legacy Mini-Split Heat Pumps — ENERGY STAR Certified Models

Across ENERGY STAR mini-split heat pumps filings, LPS Legacy accounts for 24 canonical models (35 AHRI matches) ranging from 23.9 SEER2 up to 33.1 SEER2 (6,000-47,000 BTU/h). LPS Legacy Mini-Split Heat Pumps — ENERGY STAR Certified Models benchmarks residential systems using Certified Models set at 24 and Rating Span set at 23.9 SEER2 - 33.1 SEER2.

- **Certified Models**: 24

- **Rating Span**: 23.9 SEER2 - 33.1 SEER2

- **Capacity Range**: 6,000-47,000 BTU/h

- **AHRI Combinations**: 35

- **Cold Climate Units**: 24

- **Category Median**: 25.1 SEER2

LPS Legacy Mini-Split Heat Pumps — ENERGY STAR Certified Models editorial reference. ThermalSpec Editorial Photography

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).

## How does LPS Legacy's mini-split heat pumps portfolio cover capacity, refrigerants, and safety?

LPS Legacy covers 6,000-47,000 BTU/h in mini-split heat pumps across 24 canonical models and 35 AHRI combinations, with 24 Cold Climate certified models and R-410A, R-454B. Ratings span 23.9 SEER2 up to 33.1 SEER2 (category median 25.1 SEER2, certified through 2026-06-13). CPSC records show 0 residential HVAC recall notices matching LPS Legacy; check exact AHRI matched pairings on individual model sheets.

Filter this directory

Showing **24** entries

## Which verified records belong in LPS Legacy Mini-Split Heat Pumps — ENERGY STAR Certified Models?

Compare all 24 verified entries below. Click any column header to sort numerically or alphabetically, then select any row for full benchmark citations.

All 24 ENERGY STAR LPS Legacy Mini-Split Heat Pumps Models

| [LPS Legacy DLCSRBH09AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-dlcsrbh09aak/) | 28.1 SEER2 | 12.4 HSPF2 | 9,000 BTU/h | 4 |
|---|---|---|---|---|
| [LPS Legacy D5CSHAH09AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5cshah09aak/) | 27.5 SEER2 | 12.5 HSPF2 | 9,000 BTU/h | 3 |
| [LPS Legacy DLCPRBH09AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-dlcprbh09aak/) | 27.0 SEER2 | 15.0 HSPF2 | 9,000 BTU/h | 2 |
| [LPS Legacy D5CSRAH09AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5csrah09aak/) | 26.0 SEER2 | 13.9 HSPF2 | 9,000 BTU/h | 2 |
| [LPS Legacy D5CSHAH12AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5cshah12aak/) | 25.5 SEER2 | 10.6 HSPF2 | 12,000 BTU/h | 2 |
| [LPS Legacy D5CSRAH12AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5csrah12aak/) | 25.5 SEER2 | 11.0 HSPF2 | 12,000 BTU/h | 2 |
| [LPS Legacy DLCSRBH12AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-dlcsrbh12aak/) | 25.5 SEER2 | 10.7 HSPF2 | 12,000 BTU/h | 2 |
| [LPS Legacy DLCPRBH12AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-dlcprbh12aak/) | 25.3 SEER2 | 11.7 HSPF2 | 12,000 BTU/h | 2 |
| [LPS Legacy D5CPRAH06AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5cprah06aak/) | 33.1 SEER2 | 15.6 HSPF2 | 6,000 BTU/h | 1 |
| [LPS Legacy D5CPRAH09AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5cprah09aak/) | 31.5 SEER2 | 14.6 HSPF2 | 9,000 BTU/h | 1 |
| [LPS Legacy D5CPRAH12AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5cprah12aak/) | 28.0 SEER2 | 12.7 HSPF2 | 12,000 BTU/h | 1 |
| [LPS Legacy DLCSRBH06AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-dlcsrbh06aak/) | 26.5 SEER2 | 13.6 HSPF2 | 6,000 BTU/h | 1 |
| [LPS Legacy DLCPRBH18AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-dlcprbh18aak/) | 26.3 SEER2 | 11.0 HSPF2 | 18,000 BTU/h | 1 |
| [LPS Legacy D5CSHAH06AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5cshah06aak/) | 25.7 SEER2 | 14.8 HSPF2 | 6,000 BTU/h | 1 |
| [LPS Legacy D5CMRAH18CAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5cmrah18cak/) | 25.2 SEER2 | 9.8 HSPF2 | 18,000 BTU/h | 1 |
| [LPS Legacy D5CMHAH18CAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5cmhah18cak/) | 25.0 SEER2 | 10.5 HSPF2 | 19,000 BTU/h | 1 |
| [LPS Legacy D5CMRAH24DAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5cmrah24dak/) | 25.0 SEER2 | 9.5 HSPF2 | 24,000 BTU/h | 1 |
| [LPS Legacy D5CMRAH30EAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5cmrah30eak/) | 25.0 SEER2 | 10.0 HSPF2 | 30,000 BTU/h | 1 |
| [LPS Legacy D5CPRAH18AA](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5cprah18aa/) | 24.5 SEER2 | 15.2 HSPF2 | 18,000 BTU/h | 1 |
| [LPS Legacy D5CMHAH24DAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5cmhah24dak/) | 24.0 SEER2 | 10.0 HSPF2 | 24,000 BTU/h | 1 |
| [LPS Legacy D5CMHAH30EAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5cmhah30eak/) | 24.0 SEER2 | 10.7 HSPF2 | 30,000 BTU/h | 1 |
| [LPS Legacy D5CMRAH36EAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5cmrah36eak/) | 24.0 SEER2 | 9.5 HSPF2 | 36,000 BTU/h | 1 |
| [LPS Legacy D5CMRAH48FAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5cmrah48fak/) | 24.0 SEER2 | 10.4 HSPF2 | 47,000 BTU/h | 1 |
| [LPS Legacy D5CSRAH18AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5csrah18aak/) | 23.9 SEER2 | 13.5 HSPF2 | 16,000 BTU/h | 1 |

## Which top LPS Legacy mini-split heat pumps anchor this lineup?

Select any of the 4 verified listings below to open detailed specifications, safety boundaries, and source links.

LPS Legacy28.1 SEER2

### [LPS Legacy DLCSRBH09AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-dlcsrbh09aak/)

12.4 HSPF2 | 9,000 BTU/h | 4 SKUs

PD ID 2450408 [Inspect](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-dlcsrbh09aak/)

LPS Legacy27.5 SEER2

### [LPS Legacy D5CSHAH09AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5cshah09aak/)

12.5 HSPF2 | 9,000 BTU/h | 3 SKUs

PD ID 3556698 [Inspect](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5cshah09aak/)

LPS Legacy27.0 SEER2

### [LPS Legacy DLCPRBH09AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-dlcprbh09aak/)

15.0 HSPF2 | 9,000 BTU/h | 2 SKUs

PD ID 2448974 [Inspect](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-dlcprbh09aak/)

LPS Legacy26.0 SEER2

### [LPS Legacy D5CSRAH09AAK](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5csrah09aak/)

13.9 HSPF2 | 9,000 BTU/h | 2 SKUs

PD ID 3556725 [Inspect](https://myhomeheating.org/equipment/mini-splits/lps-legacy/lps-legacy-d5csrah09aak/)

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on LPS Legacy Mini-Split Heat Pumps, review 3 important real-world limits and verify local licensing and permit rules directly.

- Cohort spread across LPS Legacy: 23.9 SEER2 entry units differ substantially from flagship DLCSRBH09AAK (33.1 SEER2).
- Verify indoor coil AHRI pairing on PD ID 2450408 and 3556737 before pulling state mechanical permits.
- Equipment catalog metrics exclude ductwork upgrades, A2L leak sensors where applicable, and municipal inspection fees.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Best fit for LPS Legacy** | Homes matched to 6,000-47,000 BTU/h seeking R-410A, R-454B compliance and verified ENERGY STAR documentation. |
| **Skip or verify further if** | Existing ductwork pushes total static pressure above 0.50 in. w.c. or 3-phase commercial wiring is present. |

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

LPS Legacy Peak

### Which LPS Legacy mini-split heat pumps model reaches the highest 33.1 SEER2 rating?

DLCSRBH09AAK tops LPS Legacy's 24 ENERGY STAR mini-split heat pumps models at 33.1 SEER2 across 4 AHRI matches (PD ID 2450408).

Lineup Span

### How broad is LPS Legacy's mini-split heat pumps efficiency and BTU range?

LPS Legacy spans 23.9 SEER2 (D5CSRAH18AAK) up to 33.1 SEER2 (DLCSRBH09AAK) across 6,000-47,000 BTU/h, compared with the 25.1 SEER2 category median.

AHRI Pairs

### How many AHRI combinations support LPS Legacy mini-split heat pumps?

Current ENERGY STAR datasets document 35 verified indoor-outdoor AHRI combinations distributed across 24 canonical LPS Legacy models.

Cold / Fuel

### What refrigerants or fuels power LPS Legacy mini-split heat pumps?

LPS Legacy mini-split heat pumps listings record R-410A, R-454B, with 24 Cold Climate certified models inside the mini-split heat pumps cohort.

DOE Regions

### Where are LPS Legacy mini-split heat pumps compliant under 2026 federal rules?

Models meeting 13.4 SEER2 qualify in the North; 14.3 SEER2 (plus 11.7 EER2 or 9.8 at 15.2+ SEER2) is needed for Southwest split cooling, while split heat pumps require 14.3 SEER2 / 7.5 HSPF2 nationwide.

CPSC Recalls

### Are any CPSC safety recalls linked to LPS Legacy residential HVAC products?

ThermalSpec counts 0 residential HVAC CPSC filings referencing LPS Legacy; verify model serial prefixes at /recalls/ before installation or service.

 25C Tax Credit

### Do LPS Legacy mini-split heat pumps receive federal Section 25C credits in 2026?

No — IRS Section 25C credits terminated December 31, 2025 ($0 federal tax credit for LPS Legacy in 2026). Check state HOMES/HEAR and local utility ENERGY STAR rebates using PD ID 2450408.

Sizing Rule

### How should homeowners select among LPS Legacy's 24 mini-split heat pumps models?

Match LPS Legacy model capacity (6,000-47,000 BTU/h) using an ACCA Manual J room-by-room heat load and <= 0.50 in. w.c. static pressure check rather than old unit tonnage.

## Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Mini-Split-Heat-Pumps/akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-84) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
4. [Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 6 pages.

[ All Mini-Split Heat Pumps Brands (185) → ](https://myhomeheating.org/equipment/mini-splits/) [ Check 51-State DOE Minimum SEER2 Rules → ](https://myhomeheating.org/states/) [ Heat Pump vs. Gas Operating Calculator → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ SMART COMFORT Mini-Split Heat Pumps — ENERGY STAR Certifie → ](https://myhomeheating.org/equipment/mini-splits/smart-comfort/) [ Tempstar Mini-Split Heat Pumps — ENERGY STAR Certified Mod → ](https://myhomeheating.org/equipment/mini-splits/tempstar/) [ ECO-AIR Mini-Split Heat Pumps — ENERGY STAR Certified Mode → ](https://myhomeheating.org/equipment/mini-splits/eco-air/)
