# GREE GS09HP230V1CLO — Mini-Split Heat Pump Specifications

GREE GS09HP230V1CLO (Mini-Split Heat Pump, PD ID 4688463) holds 3 ENERGY STAR certified SKUs rated at 26.0 SEER2 — #595 of 2,096 (Top 33.4%, 106 tied), +0.90 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). GREE GS09HP230V1CLO — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 26.0 SEER2 and Heating Rating set at 10.4 HSPF2.

- **Max SEER2**: 26.0 SEER2

- **Heating Rating**: 10.4 HSPF2

- **Heating COP**: 1.95 COP

- **Cohort Rank**: #595/2,096

- **Verified Combos**: 3 SKUs

- **Sample PD ID**: 4688463

Mini-Split Heat Pump Efficiency Spread across 2096 certified series (23.7 to 35.1 SEER2)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | This series |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |

GREE GS09HP230V1CLO residential equipment inspection. ThermalSpec Editorial Photography

## How does GREE GS09HP230V1CLO rank across federal compliance and ENERGY STAR cohorts?

GREE GS09HP230V1CLO ranks #595 of 2,096 (tied with 105 others at 26.0 SEER2, top 33.4%, more efficient than 66.6% of certified series) for Max SEER2 (+0.90 SEER2 vs 25.1 SEER2 category median) across 3 certified SKU combinations. Rated for cold-climate output (95.2% capacity retention at 5F) (0.8 nominal Tons at 9,100 BTU/h) charged with R-32. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.

GREE GS09HP230V1CLO Cohort Metrics vs. Mini-Split Heat Pump Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Max SEER2)** | #595 of 2,096 (Top 33.4%, 106 tied) | +0.90 SEER2 vs 25.1 SEER2 category median |
| **Heating HSPF2 vs Cohort** | 10.4 HSPF2 | -0.10 HSPF2 vs 10.5 HSPF2 median |
| **Peak 95F EER2 vs Cohort** | 15.0 EER2 | +1.00 EER2 vs 14.0 EER2 median |
| **5F Cold-Weather Capacity Retention** | 95.2% of 47F rating | 5F COP 1.95 |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **Federal North & SE Heat Pump Minimum** | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 26.0 SEER2 / 10.4 HSPF2 |
| **Southwest Peak-Heat Criterion (AZ/CA/NM/NV)** | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 15.0 EER2 |
| **ENERGY STAR Cold Climate Spec** | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| **2026 Cleaner Refrigerant Rule** | R-454B / R-32 READY | Listed refrigerant: R-32; newer R-454B/R-32 splits include indoor leak sensors |

## How much annual energy and operating cost does GREE GS09HP230V1CLO require?

Modeled utility figures for GREE GS09HP230V1CLO (GREE) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max SEER2 ratings.

Cool_kWh = (9,100 BTU/h * 1,000 hrs / 26.0 SEER2) / 1,000 | Heat_kWh = 30,000 kBTU / 10.4 HSPF2

Assumes 1,000 cooling hrs + 30 MMBtu heating at US 51-state median 16.33 c/kWh (range 12.72 c NV to 47.18 c HI)

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **Estimated Annual Cooling Energy** | 350 kWh/yr | $57/yr at US median |
| **Estimated Annual Heating Energy (30 MMBtu)** | 2,885 kWh/yr | $471/yr at US median |
| **Combined Annual Electricity Cost** | $528/yr | State range: $411 (NV) to $1,526 (HI) |
| **Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor** | 1,401 kWh/yr | $229/yr saved |

UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

## Which AHRI certified SKU combinations belong to GREE GS09HP230V1CLO?

Showing 3 certified indoor-outdoor coil combinations from 3 total AHRI matched records filed for GREE GS09HP230V1CLO (PD ID 4688463).

| GS09HP230V1CLO | GS09HP230V1CLI | 9,100 BTU/h | 26.0 SEER2 / 10.4 HSPF2 |
|---|---|---|---|
| GS09HP230V1CLO | GS09HP230V1FCI | 9,100 BTU/h | 25.0 SEER2 / 9.6 HSPF2 |
| GS09HP230V1CLO | GS09HP230V1CASI | 9,100 BTU/h | 24.0 SEER2 / 9.2 HSPF2 |

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on GREE GS09HP230V1CLO, review 3 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across GREE GS09HP230V1CLO: headline Max SEER2 reflects peak tested matches among 3 SKUs, not lower-rated sizes.
- Catalog specs for GREE GS09HP230V1CLO exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- GREE GS09HP230V1CLO uses A2L R-32, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal GREE GS09HP230V1CLO fit** | Single-family replacement needing documented ENERGY STAR PD ID 4688463 with matching indoor air handler. |
| **Skip GREE GS09HP230V1CLO if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable mini-split heat pump models deliver similar efficiency?

Compare GREE GS09HP230V1CLO against AireForce DXH09PSK3IH and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.

### [AireForce DXH09PSK3IH](https://myhomeheating.org/equipment/mini-splits/aireforce/aireforce-dxh09psk3ih/)

26.0 SEER2 · 10.4 HSPF2 · 9,100 BTU/h

### [Airtemp DXH09PSK3IH](https://myhomeheating.org/equipment/mini-splits/airtemp/airtemp-dxh09psk3ih/)

26.0 SEER2 · 10.4 HSPF2 · 9,100 BTU/h

### [BLUERIDGE BXS4Z09UC0](https://myhomeheating.org/equipment/mini-splits/blueridge/blueridge-bxs4z09uc0/)

26.0 SEER2 · 10.4 HSPF2 · 9,100 BTU/h

### [BOREAL KUL09HPJ132OA](https://myhomeheating.org/equipment/mini-splits/boreal/boreal-kul09hpj132oa/)

26.0 SEER2 · 10.4 HSPF2 · 9,100 BTU/h

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does GREE GS09HP230V1CLO compare with peer Mini-Split Heat Pump units?

GREE GS09HP230V1CLO holds #595 of 2,096 (Top 33.4%, 106 tied) out of 2,096 verified mini-split heat pump models (+0.90 SEER2 vs 25.1 SEER2 category median), spanning 3 certified SKUs up to 26.0 SEER2. Closest same-cohort alternatives include AireForce DXH09PSK3IH.

DOE Regions

### Where is GREE GS09HP230V1CLO compliant for 2026 US installation?

GREE GS09HP230V1CLO: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does GREE GS09HP230V1CLO model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, GREE GS09HP230V1CLO runs 350 kWh/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does GREE GS09HP230V1CLO cover?

GREE GS09HP230V1CLO covers 9,100-9,100 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does GREE GS09HP230V1CLO handle extreme weather or cold snaps?

Yes, GREE GS09HP230V1CLO carries ENERGY STAR Cold Climate certification (95.2% capacity retention at 5 F).

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern GREE GS09HP230V1CLO?

GREE GS09HP230V1CLO specifies R-32 compliance (PD ID 4688463); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 3 certified SKUs in GREE GS09HP230V1CLO reach 26.0 SEER2?

Peak 26.0 SEER2 represents the top tested AHRI pairing for GREE GS09HP230V1CLO (PD ID 4688463); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to GREE GS09HP230V1CLO?

GREE GS09HP230V1CLO requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include AireForce DXH09PSK3IH.

## Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Mini-Split-Heat-Pumps/akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
4. [40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-84) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
5. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
6. [Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

[ All GREE Mini-Split Heat Pumps (79) → ](https://myhomeheating.org/equipment/mini-splits/gree/) [ All Mini-Split Heat Pumps (2,096) → ](https://myhomeheating.org/equipment/mini-splits/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare AireForce DXH09PSK3IH (26.0 SEER2) → ](https://myhomeheating.org/equipment/mini-splits/aireforce/aireforce-dxh09psk3ih/) [ Compare Airtemp DXH09PSK3IH (26.0 SEER2) → ](https://myhomeheating.org/equipment/mini-splits/airtemp/airtemp-dxh09psk3ih/) [ GREE GS09HP230V1PUO → ](https://myhomeheating.org/equipment/mini-splits/gree/gree-gs09hp230v1puo/) [ GREE VIR09HP230V1R32AO → ](https://myhomeheating.org/equipment/mini-splits/gree/gree-vir09hp230v1r32ao/) [ Kinghome KW09XQ25SDO → ](https://myhomeheating.org/equipment/mini-splits/kinghome/kinghome-kw09xq25sdo/)

GREE Quick Spec Summary

- **Cohort Rank**: #595/2,096

- **Max SEER2**: top 33.4%, 106 tied

- **Verified SKUs**: 3

- **Brand Hub**: [GREE](https://myhomeheating.org/equipment/mini-splits/gree/)

- **Category Hub**: [Mini-Split Heat Pump](https://myhomeheating.org/equipment/mini-splits/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).