title: "Day & Night DLCSRBH06AAK Specs: 26.5 SEER2 (#467/2,096)"
url: https://myhomeheating.org/equipment/mini-splits/day-night/day-night-dlcsrbh06aak/
description: "Verified ENERGY STAR specs for Day & Night DLCSRBH06AAK mini-split heat pump: 26.5 SEER2, #467 of 2,096, operating cost formula, and peer models."
---

Mini-Split Heat Pump · Day & Night · 2 ENERGY STAR Combinations

# Day & Night DLCSRBH06AAK — Mini-Split Heat Pump Specifications

Day & Night DLCSRBH06AAK (Mini-Split Heat Pump, PD ID 3799070) holds 2 ENERGY STAR certified SKUs rated at 26.5 SEER2 — #467 of 2,096 (Top 25.9%, 76 tied), +1.40 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Day & Night DLCSRBH06AAK — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 26.5 SEER2 and Heating Rating set at 13.6 HSPF2.

- **Max SEER2**: 26.5 SEER2

- **Heating Rating**: 13.6 HSPF2

- **Heating COP**: 2.1 COP

- **Cohort Rank**: #467/2,096

- **Verified Combos**: 2 SKUs

- **Sample PD ID**: 3799070

Mini-Split Heat Pump Efficiency Spread across 2096 certified series (23.7 to 35.1 SEER2)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | This series |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |

Day & Night DLCSRBH06AAK residential equipment inspection. ThermalSpec Editorial Photography

## How does Day & Night DLCSRBH06AAK rank across federal compliance and ENERGY STAR cohorts?

Day & Night DLCSRBH06AAK ranks #467 of 2,096 (tied with 75 others at 26.5 SEER2, top 25.9%, more efficient than 74.1% of certified series) for Max SEER2 (+1.40 SEER2 vs 25.1 SEER2 category median) across 2 certified SKU combinations. Rated for cold-climate output (107.1% capacity retention at 5F) (0.5 nominal Tons at 6,000 BTU/h) charged with R-410A.

Day & Night DLCSRBH06AAK Cohort Metrics vs. Mini-Split Heat Pump Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Max SEER2)** | #467 of 2,096 (Top 25.9%, 76 tied) | +1.40 SEER2 vs 25.1 SEER2 category median |
| **Heating HSPF2 vs Cohort** | 13.6 HSPF2 | +3.10 HSPF2 vs 10.5 HSPF2 median |
| **Peak 95F EER2 vs Cohort** | 15.8 EER2 | +1.80 EER2 vs 14.0 EER2 median |
| **5F Cold-Weather Capacity Retention** | 107.1% of 47F rating | 5F COP 2.1 |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **Federal North & SE Heat Pump Minimum** | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 26.5 SEER2 / 13.6 HSPF2 |
| **Southwest Peak-Heat Criterion (AZ/CA/NM/NV)** | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 15.8 EER2 |
| **ENERGY STAR Cold Climate Spec** | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| **2026 Cleaner Refrigerant Rule** | OLDER R-410A | Listed refrigerant: R-410A; newer R-454B/R-32 splits include indoor leak sensors |

## How much annual energy and operating cost does Day & Night DLCSRBH06AAK require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Day & Night DLCSRBH06AAK estimates reflect 2 certified SKU combinations tested under PD ID 3799070.

Cool_kWh = (6,000 BTU/h * 1,000 hrs / 26.5 SEER2) / 1,000 | Heat_kWh = 30,000 kBTU / 13.6 HSPF2

Assumes 1,000 cooling hrs + 30 MMBtu heating at US 51-state median 16.33 c/kWh (range 12.72 c NV to 47.18 c HI)

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **Estimated Annual Cooling Energy** | 226 kWh/yr | $37/yr at US median |
| **Estimated Annual Heating Energy (30 MMBtu)** | 2,206 kWh/yr | $360/yr at US median |
| **Combined Annual Electricity Cost** | $397/yr | State range: $309 (NV) to $1,147 (HI) |
| **Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor** | 1,988 kWh/yr | $325/yr saved |

UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

## Which AHRI certified SKU combinations belong to Day & Night DLCSRBH06AAK?

Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for Day & Night DLCSRBH06AAK (PD ID 3799070).

| DLCSRBH06AAK | DHMAHBQ06XA3 | 6,000 BTU/h | 26.5 SEER2 / 13.6 HSPF2 |
|---|---|---|---|
| DLCSRBH06AAK | DLFSHCH06XAK | 6,000 BTU/h | 26.5 SEER2 / 13.6 HSPF2 |

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Day & Night DLCSRBH06AAK, review 2 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across Day & Night DLCSRBH06AAK: headline Max SEER2 reflects peak tested matches among 2 SKUs, not lower-rated sizes.
- Catalog specs for Day & Night DLCSRBH06AAK exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal Day & Night DLCSRBH06AAK fit** | Single-family replacement needing documented ENERGY STAR PD ID 3799070 with matching indoor air handler. |
| **Skip Day & Night DLCSRBH06AAK if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable mini-split heat pump models deliver similar efficiency?

Compare Day & Night DLCSRBH06AAK against 1HVAC ACIQ-06ZPL-HP230B and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.

### [1HVAC ACIQ-06ZPL-HP230B](https://myhomeheating.org/equipment/mini-splits/1hvac/1hvac-aciq-06zpl-hp230b/)

26.5 SEER2 · 13.6 HSPF2 · 6,000 BTU/h

### [ACIQ-06ZPL-HP230B](https://myhomeheating.org/equipment/mini-splits/aciq/aciq-aciq-06zpl-hp230b/)

26.5 SEER2 · 13.6 HSPF2 · 6,000 BTU/h

### [Airquest DLCSRBH06AAK](https://myhomeheating.org/equipment/mini-splits/airquest/airquest-dlcsrbh06aak/)

26.5 SEER2 · 13.6 HSPF2 · 6,000 BTU/h

### [Arcoaire DLCSRBH06AAK](https://myhomeheating.org/equipment/mini-splits/arcoaire/arcoaire-dlcsrbh06aak/)

26.5 SEER2 · 13.6 HSPF2 · 6,000 BTU/h

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does Day & Night DLCSRBH06AAK compare with peer Mini-Split Heat Pump units?

Day & Night DLCSRBH06AAK holds #467 of 2,096 (Top 25.9%, 76 tied) out of 2,096 verified mini-split heat pump models (+1.40 SEER2 vs 25.1 SEER2 category median), spanning 2 certified SKUs up to 26.5 SEER2. Closest same-cohort alternatives include 1HVAC ACIQ-06ZPL-HP230B.

DOE Regions

### Where is Day & Night DLCSRBH06AAK compliant for 2026 US installation?

Day & Night DLCSRBH06AAK: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does Day & Night DLCSRBH06AAK model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Day & Night DLCSRBH06AAK runs 226 kWh/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does Day & Night DLCSRBH06AAK cover?

Day & Night DLCSRBH06AAK covers 6,000-6,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does Day & Night DLCSRBH06AAK handle extreme weather or cold snaps?

Yes, Day & Night DLCSRBH06AAK carries ENERGY STAR Cold Climate certification (107.1% capacity retention at 5 F).

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern Day & Night DLCSRBH06AAK?

Day & Night DLCSRBH06AAK specifies R-410A compliance (PD ID 3799070); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 2 certified SKUs in Day & Night DLCSRBH06AAK reach 26.5 SEER2?

Peak 26.5 SEER2 represents the top tested AHRI pairing for Day & Night DLCSRBH06AAK (PD ID 3799070); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to Day & Night DLCSRBH06AAK?

Day & Night DLCSRBH06AAK requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include 1HVAC ACIQ-06ZPL-HP230B.

## Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Mini-Split-Heat-Pumps/akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
4. [40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-84) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
5. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
6. [Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

[ All Day & Night Mini-Split Heat Pumps (24) → ](https://myhomeheating.org/equipment/mini-splits/day-night/) [ All Mini-Split Heat Pumps (2,096) → ](https://myhomeheating.org/equipment/mini-splits/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare 1HVAC ACIQ-06ZPL-HP230B (26.5 SEER2) → ](https://myhomeheating.org/equipment/mini-splits/1hvac/1hvac-aciq-06zpl-hp230b/) [ Compare ACIQ-06ZPL-HP230B (26.5 SEER2) → ](https://myhomeheating.org/equipment/mini-splits/aciq/aciq-aciq-06zpl-hp230b/) [ ECO-AIR MOX230-09HFN1-MW5W → ](https://myhomeheating.org/equipment/mini-splits/eco-air/eco-air-mox230-09hfn1-mw5w/) [ Elios DEA06HOS28230E8 → ](https://myhomeheating.org/equipment/mini-splits/elios/elios-dea06hos28230e8/) [ EMI MHSZ106DA → ](https://myhomeheating.org/equipment/mini-splits/emi/emi-mhsz106da/)

Day & Night Quick Spec Summary

- **Cohort Rank**: #467/2,096

- **Max SEER2**: top 25.9%, 76 tied

- **Verified SKUs**: 2

- **Brand Hub**: [Day & Night](https://myhomeheating.org/equipment/mini-splits/day-night/)

- **Category Hub**: [Mini-Split Heat Pump](https://myhomeheating.org/equipment/mini-splits/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).