title: "Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) Specs: 22.8 SEER2"
url: https://myhomeheating.org/equipment/heat-pumps/lennox/lennox-sl25xpv-024-230a-22k-cba38mv/
description: "Verified ENERGY STAR specs for Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) air-source heat pump: 22.8 SEER2, #58 of 586, operating cost formula, and peer models."
---

Air-Source Heat Pump · Lennox · 1 ENERGY STAR Combinations

# Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) — Air-Source Heat Pump Specifications

Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) (Air-Source Heat Pump, PD ID 2452044) holds 1 ENERGY STAR certified SKU rated at 22.8 SEER2 — #58 of 586 (Top 9.9%), +0.80 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) — Air-Source Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 22.8 SEER2 and Heating Rating set at 9.2 HSPF2.

- **Max SEER2**: 22.8 SEER2

- **Heating Rating**: 9.2 HSPF2

- **Heating COP**: 1.88 COP

- **Cohort Rank**: #58/586

- **Verified Combos**: 1 SKU

- **Sample PD ID**: 2452044

Air-Source Heat Pump Efficiency Spread across 586 certified series (21.5 to 25.0 SEER2)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 21.5 - 21.9 SEER2 | 33 | Peer range |
| 21.9 - 22.3 SEER2 | 407 | Peer range |
| 22.3 - 22.7 SEER2 | 88 | Peer range |
| 22.7 - 23.1 SEER2 | 54 | This series |
| 23.1 - 23.4 SEER2 | 1 | Peer range |
| 23.4 - 23.8 SEER2 | 0 | Peer range |
| 23.8 - 24.2 SEER2 | 2 | Peer range |
| 24.2 - 24.6 SEER2 | 0 | Peer range |
| 24.6 - 25.0 SEER2 | 1 | Peer range |

Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) residential equipment inspection. ThermalSpec Editorial Photography

## How does Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) rank across federal compliance and ENERGY STAR cohorts?

Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) ranks #58 of 586 (top 9.9%, more efficient than 90.1% of certified series) for Max SEER2 (+0.80 SEER2 vs 22.0 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (95.5% capacity retention at 5F) (1.9 nominal Tons at 22,200 BTU/h) charged with R-410A. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.

Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) Cohort Metrics vs. Air-Source Heat Pump Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Max SEER2)** | #58 of 586 (Top 9.9%) | +0.80 SEER2 vs 22.0 SEER2 category median |
| **Heating HSPF2 vs Cohort** | 9.2 HSPF2 | +0.20 HSPF2 vs 9.0 HSPF2 median |
| **Peak 95F EER2 vs Cohort** | 14.4 EER2 | +1.90 EER2 vs 12.5 EER2 median |
| **5F Cold-Weather Capacity Retention** | 95.5% of 47F rating | 5F COP 1.88 |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **Federal North & SE Heat Pump Minimum** | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 22.8 SEER2 / 9.2 HSPF2 |
| **Southwest Peak-Heat Criterion (AZ/CA/NM/NV)** | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 14.4 EER2 |
| **ENERGY STAR Cold Climate Spec** | CERTIFIED | Cold Climate verified (580/586 series in category) |
| **2026 Cleaner Refrigerant Rule** | OLDER R-410A | Listed refrigerant: R-410A; newer R-454B/R-32 splits include indoor leak sensors |

## How much annual energy and operating cost does Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) require?

Annual cost outputs combine Lennox SL25XPV-024-230A** (CBA38MV- 1.9T)'s 22.8 SEER2 rating and EIA national tariffs across single-family runtime hours.

Cool_kWh = (22,200 BTU/h * 1,000 hrs / 22.8 SEER2) / 1,000 | Heat_kWh = 30,000 kBTU / 9.2 HSPF2

Assumes 1,000 cooling hrs + 30 MMBtu heating at US 51-state median 16.33 c/kWh (range 12.72 c NV to 47.18 c HI)

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **Estimated Annual Cooling Energy** | 974 kWh/yr | $159/yr at US median |
| **Estimated Annual Heating Energy (30 MMBtu)** | 3,261 kWh/yr | $533/yr at US median |
| **Combined Annual Electricity Cost** | $692/yr | State range: $539 (NV) to $1,998 (HI) |
| **Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor** | 1,317 kWh/yr | $215/yr saved |

UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

## Which AHRI certified SKU combinations belong to Lennox SL25XPV-024-230A** (CBA38MV- 1.9T)?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) (PD ID 2452044).

| SL25XPV-024-230A** | CBA38MV-030-230*+TDR | 22,200 BTU/h | 22.8 SEER2 / 9.2 HSPF2 |
|---|---|---|---|

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Lennox SL25XPV-024-230A** (CBA38MV- 1.9T), review 2 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across Lennox SL25XPV-024-230A** (CBA38MV- 1.9T): headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) fit** | Single-family replacement needing documented ENERGY STAR PD ID 2452044 with matching indoor air handler. |
| **Skip Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable air-source heat pump models deliver similar efficiency?

Compare Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) against ACIQ B5H3V24*K*AAA* (EVD5X38M 2.0T) and closely matched air-source heat pump units sharing similar Max SEER2 output and BTU tonnage.

### [ACIQ B5H3V24*K*AAA* (EVD5X38M 2.0T)](https://myhomeheating.org/equipment/heat-pumps/aciq/aciq-b5h3v24-k-aaa-24k-evd5x38m/)

23.0 SEER2 · 9.5 HSPF2 · 23,800 BTU/h

### [ACIQ B5H3V24*K*AAA* (EVM5X32M 2.0T)](https://myhomeheating.org/equipment/heat-pumps/aciq/aciq-b5h3v24-k-aaa-24k-evm5x32m/)

23.0 SEER2 · 9.5 HSPF2 · 23,800 BTU/h

### [ACIQ B5H3V24*K*AAA* (EVM5X44M 2.0T)](https://myhomeheating.org/equipment/heat-pumps/aciq/aciq-b5h3v24-k-aaa-24k-evm5x44m/)

23.0 SEER2 · 9.5 HSPF2 · 23,800 BTU/h

### [Airquest B5H3V24*K*AAA* (EVD5X38M 2.0T)](https://myhomeheating.org/equipment/heat-pumps/airquest/airquest-b5h3v24-k-aaa-24k-evd5x38m/)

23.0 SEER2 · 9.5 HSPF2 · 23,800 BTU/h

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) compare with peer Air-Source Heat Pump units?

Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) holds #58 of 586 (Top 9.9%) out of 586 verified air-source heat pump models (+0.80 SEER2 vs 22.0 SEER2 category median), spanning 1 certified SKU up to 22.8 SEER2. Closest same-cohort alternatives include ACIQ B5H3V24*K*AAA* (EVD5X38M 2.0T).

DOE Regions

### Where is Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) compliant for 2026 US installation?

Lennox SL25XPV-024-230A** (CBA38MV- 1.9T): Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) runs 974 kWh/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) cover?

Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) covers 22,200-22,200 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) handle extreme weather or cold snaps?

Yes, Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) carries ENERGY STAR Cold Climate certification (95.5% capacity retention at 5 F).

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern Lennox SL25XPV-024-230A** (CBA38MV- 1.9T)?

Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) specifies R-410A compliance (PD ID 2452044); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 1 certified SKU in Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) reach 22.8 SEER2?

Peak 22.8 SEER2 represents the top tested AHRI pairing for Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) (PD ID 2452044); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to Lennox SL25XPV-024-230A** (CBA38MV- 1.9T)?

Lennox SL25XPV-024-230A** (CBA38MV- 1.9T) requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include ACIQ B5H3V24*K*AAA* (EVD5X38M 2.0T).

## Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Air-Source Heat Pumps Dataset (w7cv-9xjt)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Air-Source-Heat-Pumps/w7cv-9xjt) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
4. [40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-84) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
5. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
6. [Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

[ All Lennox Air-Source Heat Pumps (1) → ](https://myhomeheating.org/equipment/heat-pumps/lennox/) [ All Air-Source Heat Pumps (586) → ](https://myhomeheating.org/equipment/heat-pumps/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare ACIQ B5H3V24*K*AAA* (EVD5X38M 2.0T) (23.0 SEER2) → ](https://myhomeheating.org/equipment/heat-pumps/aciq/aciq-b5h3v24-k-aaa-24k-evd5x38m/) [ Compare ACIQ B5H3V24*K*AAA* (EVM5X32M 2.0T) (23.0 SEER2) → ](https://myhomeheating.org/equipment/heat-pumps/aciq/aciq-b5h3v24-k-aaa-24k-evm5x32m/) [ ACIQ B5H3V36*K*AAA* (EVD5X42M 3.0T) → ](https://myhomeheating.org/equipment/heat-pumps/aciq/aciq-b5h3v36-k-aaa-35k-evd5x42m/) [ ACIQ B5H3V36*K*AAA* (EVD5X60M 3.0T) → ](https://myhomeheating.org/equipment/heat-pumps/aciq/aciq-b5h3v36-k-aaa-35k-evd5x60m/) [ ACIQ B5H3V36*K*AAA* (EVM5X60M 3.0T) → ](https://myhomeheating.org/equipment/heat-pumps/aciq/aciq-b5h3v36-k-aaa-35k-evm5x60m/)

Lennox Quick Spec Summary

- **Cohort Rank**: #58/586

- **Max SEER2**: top 9.9%

- **Verified SKUs**: 1

- **Brand Hub**: [Lennox](https://myhomeheating.org/equipment/heat-pumps/lennox/)

- **Category Hub**: [Air-Source Heat Pump](https://myhomeheating.org/equipment/heat-pumps/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).