---
title: "CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) Specs"
url: https://myhomeheating.org/equipment/heat-pumps/champion-heating-and-cooling/champion-heating-and-cooling-xh960e2c11-48k-ctm60c5c/
description: "Verified ENERGY STAR specs for CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) air-source heat pump: 22.0 SEER2, #147 of 586, operating cost formula, and."
---

Air-Source Heat Pump · CHAMPION HEATING AND COOLING · 2 ENERGY STAR Combinations

# CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) — Air-Source Heat Pump Specifications

CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) (Air-Source Heat Pump, PD ID 4649893) holds 2 ENERGY STAR certified SKUs rated at 22.0 SEER2 — #147 of 586 (407 tied at median), Equal to 22.0 SEER2 category median. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2).

- **Max SEER2**: 22.0 SEER2

- **Heating Rating**: 9.0 HSPF2

- **Heating COP**: 2.0 COP

- **Cohort Rank**: #147/586

- **Verified Combos**: 2 SKUs

- **Sample PD ID**: 4649893

Air-Source Heat Pump Efficiency Spread across 586 certified series (21.5 to 25.0 SEER2)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 21.5 - 21.9 SEER2 | 33 | Peer range |
| 21.9 - 22.3 SEER2 | 407 | This series |
| 22.3 - 22.7 SEER2 | 88 | Peer range |
| 22.7 - 23.1 SEER2 | 54 | Peer range |
| 23.1 - 23.4 SEER2 | 1 | Peer range |
| 23.4 - 23.8 SEER2 | 0 | Peer range |
| 23.8 - 24.2 SEER2 | 2 | Peer range |
| 24.2 - 24.6 SEER2 | 0 | Peer range |
| 24.6 - 25.0 SEER2 | 1 | Peer range |

CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) residential equipment inspection. ThermalSpec Editorial Photography

## How does CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) rank across federal compliance and ENERGY STAR cohorts?

CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) ranks #147 of 586 (tied with 406 others at 22.0 SEER2, more efficient than 5.6% of certified series) for Max SEER2 (Equal to 22.0 SEER2 category median) across 2 certified SKU combinations. Rated for cold-climate output (92.7% capacity retention at 5F) (4.0 nominal Tons at 48,000 BTU/h) charged with R-454B.

CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) Cohort Metrics vs. Air-Source Heat Pump Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Max SEER2)** | #147 of 586 (407 tied at median) | Equal to 22.0 SEER2 category median |
| **Heating HSPF2 vs Cohort** | 9.0 HSPF2 | Equal to 9.0 HSPF2 median |
| **Peak 95F EER2 vs Cohort** | 12.0 EER2 | -0.50 EER2 vs 12.5 EER2 median |
| **5F Cold-Weather Capacity Retention** | 92.7% of 47F rating | 5F COP 2.0 |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **Federal North & SE Heat Pump Minimum** | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 22.0 SEER2 / 9.0 HSPF2 |
| **Southwest Peak-Heat Criterion (AZ/CA/NM/NV)** | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 12.0 EER2 |
| **ENERGY STAR Cold Climate Spec** | CERTIFIED | Cold Climate verified (580/586 series in category) |
| **2026 Cleaner Refrigerant Rule** | R-454B / R-32 READY | Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors |

## How much annual energy and operating cost does CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) estimates reflect 2 certified SKU combinations tested under PD ID 4649893.

Cool_kWh = (48,000 BTU/h * 1,000 hrs / 22.0 SEER2) / 1,000 | Heat_kWh = 30,000 kBTU / 9.0 HSPF2

Assumes 1,000 cooling hrs + 30 MMBtu heating at US 51-state median 16.33 c/kWh (range 12.72 c NV to 47.18 c HI)

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **Estimated Annual Cooling Energy** | 2,182 kWh/yr | $356/yr at US median |
| **Estimated Annual Heating Energy (30 MMBtu)** | 3,333 kWh/yr | $544/yr at US median |
| **Combined Annual Electricity Cost** | $901/yr | State range: $702 (NV) to $2,602 (HI) |
| **Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor** | 1,842 kWh/yr | $301/yr saved |

UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

## Which AHRI certified SKU combinations belong to CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T)?

Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) (PD ID 4649893).

| XH960E2C11 | CTM60C5CGS2+JMC17C2SN1+CC | 48,000 BTU/h | 22.0 SEER2 / 9.0 HSPF2 |
|---|---|---|---|
| XH960E2C11 | CTM60C5CGS1+JMC17C2SN1+CC | 48,000 BTU/h | 22.0 SEER2 / 9.0 HSPF2 |

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T), review 3 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T): headline Max SEER2 reflects peak tested matches among 2 SKUs, not lower-rated sizes.
- Catalog specs for CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) fit** | Single-family replacement needing documented ENERGY STAR PD ID 4649893 with matching indoor air handler. |
| **Skip CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable air-source heat pump models deliver similar efficiency?

Compare CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) against Coleman XH960E2C11 (CTF60C5C 4.0T) and closely matched air-source heat pump units sharing similar Max SEER2 output and BTU tonnage.

### [Coleman XH960E2C11 (CTF60C5C 4.0T)](https://myhomeheating.org/equipment/heat-pumps/coleman/coleman-xh960e2c11-48k-ctf60c5c/)

22.0 SEER2 · 8.5 HSPF2 · 48,000 BTU/h

### [Coleman XH960E2C11 (CTM60C5C 4.0T)](https://myhomeheating.org/equipment/heat-pumps/coleman/coleman-xh960e2c11-48k-ctm60c5c/)

22.0 SEER2 · 9.0 HSPF2 · 48,000 BTU/h

### [Fraser-Johnston XH960E2C11 (CTF60C5C 4.0T)](https://myhomeheating.org/equipment/heat-pumps/fraser-johnston/fraser-johnston-xh960e2c11-48k-ctf60c5c/)

22.0 SEER2 · 8.5 HSPF2 · 48,000 BTU/h

### [Fraser-Johnston XH960E2C11 (CTM60C5C 4.0T)](https://myhomeheating.org/equipment/heat-pumps/fraser-johnston/fraser-johnston-xh960e2c11-48k-ctm60c5c/)

22.0 SEER2 · 9.0 HSPF2 · 48,000 BTU/h

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) compare with peer Air-Source Heat Pump units?

CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) holds #147 of 586 (407 tied at median) out of 586 verified air-source heat pump models (Equal to 22.0 SEER2 category median), spanning 2 certified SKUs up to 22.0 SEER2. Closest same-cohort alternatives include Coleman XH960E2C11 (CTF60C5C 4.0T).

DOE Regions

### Where is CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) compliant for 2026 US installation?

CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T): Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) runs 2,182 kWh/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) cover?

CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) covers 48,000-48,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) handle extreme weather or cold snaps?

Yes, CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) carries ENERGY STAR Cold Climate certification (92.7% capacity retention at 5 F).

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T)?

CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) specifies R-454B compliance (PD ID 4649893); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 2 certified SKUs in CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) reach 22.0 SEER2?

Peak 22.0 SEER2 represents the top tested AHRI pairing for CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) (PD ID 4649893); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T)?

CHAMPION HEATING AND COOLING XH960E2C11 (CTM60C5C 4.0T) requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Coleman XH960E2C11 (CTF60C5C 4.0T).

## Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Air-Source Heat Pumps Dataset (w7cv-9xjt)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Air-Source-Heat-Pumps/w7cv-9xjt) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
4. [40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-84) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
5. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
6. [Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 7 pages.

[ All CHAMPION HEATING AND COOLING Air-Source Heat Pumps (2) → ](https://myhomeheating.org/equipment/heat-pumps/champion-heating-and-cooling/) [ All Air-Source Heat Pumps (586) → ](https://myhomeheating.org/equipment/heat-pumps/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare Coleman XH960E2C11 (CTF60C5C 4.0T) (22.0 SEER2) → ](https://myhomeheating.org/equipment/heat-pumps/coleman/coleman-xh960e2c11-48k-ctf60c5c/) [ Compare Coleman XH960E2C11 (CTM60C5C 4.0T) (22.0 SEER2) → ](https://myhomeheating.org/equipment/heat-pumps/coleman/coleman-xh960e2c11-48k-ctm60c5c/) [ Comfortmaker B5H3V24*K*AAA* (EVD5X25M 1.9T) → ](https://myhomeheating.org/equipment/heat-pumps/comfortmaker/comfortmaker-b5h3v24-k-aaa-23k-evd5x25m/)

CHAMPION HEATING AND COOLING Quick Spec Summary

- **Cohort Rank**: #147/586

- **Max SEER2**: 407 tied, more efficient than 5.6% of certified series

- **Verified SKUs**: 2

- **Brand Hub**: [CHAMPION HEATING AND COOLING](https://myhomeheating.org/equipment/heat-pumps/champion-heating-and-cooling/)

- **Category Hub**: [Air-Source Heat Pump](https://myhomeheating.org/equipment/heat-pumps/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).
