title: "American Standard 5A6V0X24A1 (5TEMCB03 1.8T) Specs: 22.0 SEER2"
url: https://myhomeheating.org/equipment/heat-pumps/american-standard/american-standard-5a6v0x24a1-22k-5temcb03/
description: "Verified ENERGY STAR specs for American Standard 5A6V0X24A1 (5TEMCB03 1.8T) air-source heat pump: 22.0 SEER2, #147 of 586, operating cost formula, and peer."
---

Air-Source Heat Pump · American Standard · 1 ENERGY STAR Combinations

# American Standard 5A6V0X24A1 (5TEMCB03 1.8T) — Air-Source Heat Pump Specifications

American Standard 5A6V0X24A1 (5TEMCB03 1.8T) (Air-Source Heat Pump, PD ID 3846077) holds 1 ENERGY STAR certified SKU rated at 22.0 SEER2 — #147 of 586 (407 tied at median), Equal to 22.0 SEER2 category median. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2).

- **Max SEER2**: 22.0 SEER2

- **Heating Rating**: 10.0 HSPF2

- **Heating COP**: 2.2 COP

- **Cohort Rank**: #147/586

- **Verified Combos**: 1 SKU

- **Sample PD ID**: 3846077

Air-Source Heat Pump Efficiency Spread across 586 certified series (21.5 to 25.0 SEER2)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 21.5 - 21.9 SEER2 | 33 | Peer range |
| 21.9 - 22.3 SEER2 | 407 | This series |
| 22.3 - 22.7 SEER2 | 88 | Peer range |
| 22.7 - 23.1 SEER2 | 54 | Peer range |
| 23.1 - 23.4 SEER2 | 1 | Peer range |
| 23.4 - 23.8 SEER2 | 0 | Peer range |
| 23.8 - 24.2 SEER2 | 2 | Peer range |
| 24.2 - 24.6 SEER2 | 0 | Peer range |
| 24.6 - 25.0 SEER2 | 1 | Peer range |

American Standard 5A6V0X24A1 (5TEMCB03 1.8T) residential equipment inspection. ThermalSpec Editorial Photography

## How does American Standard 5A6V0X24A1 (5TEMCB03 1.8T) rank across federal compliance and ENERGY STAR cohorts?

American Standard 5A6V0X24A1 (5TEMCB03 1.8T) ranks #147 of 586 (tied with 406 others at 22.0 SEER2, more efficient than 5.6% of certified series) for Max SEER2 (Equal to 22.0 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (79.8% capacity retention at 5F) (1.8 nominal Tons at 21,600 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.

American Standard 5A6V0X24A1 (5TEMCB03 1.8T) Cohort Metrics vs. Air-Source Heat Pump Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Max SEER2)** | #147 of 586 (407 tied at median) | Equal to 22.0 SEER2 category median |
| **Heating HSPF2 vs Cohort** | 10.0 HSPF2 | +1.00 HSPF2 vs 9.0 HSPF2 median |
| **Peak 95F EER2 vs Cohort** | 11.7 EER2 | -0.80 EER2 vs 12.5 EER2 median |
| **5F Cold-Weather Capacity Retention** | 79.8% of 47F rating | 5F COP 2.2 |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **Federal North & SE Heat Pump Minimum** | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 22.0 SEER2 / 10.0 HSPF2 |
| **Southwest Peak-Heat Criterion (AZ/CA/NM/NV)** | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 11.7 EER2 |
| **ENERGY STAR Cold Climate Spec** | CERTIFIED | Cold Climate verified (580/586 series in category) |
| **2026 Cleaner Refrigerant Rule** | R-454B / R-32 READY | Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors |

## How much annual energy and operating cost does American Standard 5A6V0X24A1 (5TEMCB03 1.8T) require?

Annual cost outputs combine American Standard 5A6V0X24A1 (5TEMCB03 1.8T)'s 22.0 SEER2 rating and EIA national tariffs across single-family runtime hours.

Cool_kWh = (21,600 BTU/h * 1,000 hrs / 22.0 SEER2) / 1,000 | Heat_kWh = 30,000 kBTU / 10.0 HSPF2

Assumes 1,000 cooling hrs + 30 MMBtu heating at US 51-state median 16.33 c/kWh (range 12.72 c NV to 47.18 c HI)

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **Estimated Annual Cooling Energy** | 982 kWh/yr | $160/yr at US median |
| **Estimated Annual Heating Energy (30 MMBtu)** | 3,000 kWh/yr | $490/yr at US median |
| **Combined Annual Electricity Cost** | $650/yr | State range: $507 (NV) to $1,879 (HI) |
| **Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor** | 1,528 kWh/yr | $250/yr saved |

UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

## Which AHRI certified SKU combinations belong to American Standard 5A6V0X24A1 (5TEMCB03 1.8T)?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for American Standard 5A6V0X24A1 (5TEMCB03 1.8T) (PD ID 3846077).

| 5A6V0X24A1 | 5TEMCB03AV31+TDR | 21,600 BTU/h | 22.0 SEER2 / 10.0 HSPF2 |
|---|---|---|---|

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on American Standard 5A6V0X24A1 (5TEMCB03 1.8T), review 3 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across American Standard 5A6V0X24A1 (5TEMCB03 1.8T): headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for American Standard 5A6V0X24A1 (5TEMCB03 1.8T) exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- American Standard 5A6V0X24A1 (5TEMCB03 1.8T) uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal American Standard 5A6V0X24A1 (5TEMCB03 1.8T) fit** | Single-family replacement needing documented ENERGY STAR PD ID 3846077 with matching indoor air handler. |
| **Skip American Standard 5A6V0X24A1 (5TEMCB03 1.8T) if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable air-source heat pump models deliver similar efficiency?

Compare American Standard 5A6V0X24A1 (5TEMCB03 1.8T) against Trane 5TWV0X24A1 (5TEMCB03 1.8T) and closely matched air-source heat pump units sharing similar Max SEER2 output and BTU tonnage.

### [Trane 5TWV0X24A1 (5TEMCB03 1.8T)](https://myhomeheating.org/equipment/heat-pumps/trane/trane-5twv0x24a1-22k-5temcb03/)

22.0 SEER2 · 10.0 HSPF2 · 21,600 BTU/h

### [Trane 5TWV0X24A1 (5TAMXC03 1.8T)](https://myhomeheating.org/equipment/heat-pumps/trane/trane-5twv0x24a1-22k-5tamxc03/)

22.0 SEER2 · 9.7 HSPF2 · 21,800 BTU/h

### [Trane 5TWV0X24A1 (5PX*BD06 1.8T)](https://myhomeheating.org/equipment/heat-pumps/trane/trane-5twv0x24a1-22k-5px-bd06/)

22.0 SEER2 · 10.0 HSPF2 · 22,000 BTU/h

### [Trane 5TWV0X24A1 (5PX*BD06 1.8T)](https://myhomeheating.org/equipment/heat-pumps/trane/trane-5twv0x24a1-21k-5px-bd06/)

22.0 SEER2 · 10.0 HSPF2 · 21,000 BTU/h

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does American Standard 5A6V0X24A1 (5TEMCB03 1.8T) compare with peer Air-Source Heat Pump units?

American Standard 5A6V0X24A1 (5TEMCB03 1.8T) holds #147 of 586 (407 tied at median) out of 586 verified air-source heat pump models (Equal to 22.0 SEER2 category median), spanning 1 certified SKU up to 22.0 SEER2. Closest same-cohort alternatives include Trane 5TWV0X24A1 (5TEMCB03 1.8T).

DOE Regions

### Where is American Standard 5A6V0X24A1 (5TEMCB03 1.8T) compliant for 2026 US installation?

American Standard 5A6V0X24A1 (5TEMCB03 1.8T): Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does American Standard 5A6V0X24A1 (5TEMCB03 1.8T) model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, American Standard 5A6V0X24A1 (5TEMCB03 1.8T) runs 982 kWh/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does American Standard 5A6V0X24A1 (5TEMCB03 1.8T) cover?

American Standard 5A6V0X24A1 (5TEMCB03 1.8T) covers 21,600-21,600 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does American Standard 5A6V0X24A1 (5TEMCB03 1.8T) handle extreme weather or cold snaps?

Yes, American Standard 5A6V0X24A1 (5TEMCB03 1.8T) carries ENERGY STAR Cold Climate certification (79.8% capacity retention at 5 F).

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern American Standard 5A6V0X24A1 (5TEMCB03 1.8T)?

American Standard 5A6V0X24A1 (5TEMCB03 1.8T) specifies R-454B compliance (PD ID 3846077); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 1 certified SKU in American Standard 5A6V0X24A1 (5TEMCB03 1.8T) reach 22.0 SEER2?

Peak 22.0 SEER2 represents the top tested AHRI pairing for American Standard 5A6V0X24A1 (5TEMCB03 1.8T) (PD ID 3846077); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to American Standard 5A6V0X24A1 (5TEMCB03 1.8T)?

American Standard 5A6V0X24A1 (5TEMCB03 1.8T) requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Trane 5TWV0X24A1 (5TEMCB03 1.8T).

## Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Air-Source Heat Pumps Dataset (w7cv-9xjt)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Air-Source-Heat-Pumps/w7cv-9xjt) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
4. [40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-84) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
5. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
6. [Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

[ All American Standard Air-Source Heat Pumps (7) → ](https://myhomeheating.org/equipment/heat-pumps/american-standard/) [ All Air-Source Heat Pumps (586) → ](https://myhomeheating.org/equipment/heat-pumps/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare Trane 5TWV0X24A1 (5TEMCB03 1.8T) (22.0 SEER2) → ](https://myhomeheating.org/equipment/heat-pumps/trane/trane-5twv0x24a1-22k-5temcb03/) [ Compare Trane 5TWV0X24A1 (5TAMXC03 1.8T) (22.0 SEER2) → ](https://myhomeheating.org/equipment/heat-pumps/trane/trane-5twv0x24a1-22k-5tamxc03/) [ Arcoaire B5H3V36*K*AAA* (EVD5X42M 3.0T) → ](https://myhomeheating.org/equipment/heat-pumps/arcoaire/arcoaire-b5h3v36-k-aaa-35k-evd5x42m/) [ Arcoaire B5H3V36*K*AAA* (EVD5X60M 3.0T) → ](https://myhomeheating.org/equipment/heat-pumps/arcoaire/arcoaire-b5h3v36-k-aaa-35k-evd5x60m/) [ Arcoaire B5H3V36*K*AAA* (EVM5X60M 3.0T) → ](https://myhomeheating.org/equipment/heat-pumps/arcoaire/arcoaire-b5h3v36-k-aaa-35k-evm5x60m/)

American Standard Quick Spec Summary

- **Cohort Rank**: #147/586

- **Max SEER2**: 407 tied, more efficient than 5.6% of certified series

- **Verified SKUs**: 1

- **Brand Hub**: [American Standard](https://myhomeheating.org/equipment/heat-pumps/american-standard/)

- **Category Hub**: [Air-Source Heat Pump](https://myhomeheating.org/equipment/heat-pumps/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).