title: "Tempstar HP024V/H/C******1**1 Specs: 4.1 COP (#1,503/1,730)"
url: https://myhomeheating.org/equipment/geothermal/tempstar/tempstar-hp024v-h-c-1-1/
description: "Verified ENERGY STAR specs for Tempstar HP024V/H/C******1**1 geothermal heat pump: 4.1 COP, #1,503 of 1,730, operating cost formula, and peer models."
---

Geothermal Heat Pump · Tempstar · 1 ENERGY STAR Combinations

# Tempstar HP024V/H/C**1**1 — Geothermal Heat Pump Specifications

Tempstar HP024V/H/C**1**1 (Geothermal Heat Pump, PD ID 3845722) holds 1 ENERGY STAR certified SKU rated at 4.1 COP — #1,503 of 1,730 (120 tied, beats 6.2% of peers), -0.40 COP. ENERGY STAR certified residential HVAC model. Tempstar HP024V/H/C**1**1 — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.1 COP and Cohort Rank set at #1,503/1,730.

- **Heating COP**: 4.1 COP

- **Cohort Rank**: #1,503/1,730

- **Verified Combos**: 1 SKU

- **Sample PD ID**: 3845722

Geothermal Heat Pump Efficiency Spread across 1730 certified series (3.9 to 5.7 COP)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 3.9 - 4.1 COP | 228 | This series |
| 4.1 - 4.3 COP | 329 | Peer range |
| 4.3 - 4.5 COP | 251 | Peer range |
| 4.5 - 4.7 COP | 296 | Peer range |
| 4.7 - 4.9 COP | 244 | Peer range |
| 4.9 - 5.1 COP | 310 | Peer range |
| 5.1 - 5.3 COP | 37 | Peer range |
| 5.3 - 5.5 COP | 32 | Peer range |
| 5.5 - 5.7 COP | 3 | Peer range |

Tempstar HP024V/H/C**1**1 residential equipment inspection. ThermalSpec Editorial Photography

## How does Tempstar HP024V/H/C**1**1 rank across federal compliance and ENERGY STAR cohorts?

Tempstar HP024V/H/C**1**1 ranks #1,503 of 1,730 (tied with 119 others at 4.10 COP, more efficient than 6.2% of certified series) for Max COP (-0.40 COP vs 4.50 COP category median) across 1 certified SKU combination. Open Loop Water-to-Air unit delivering 4.1 COP and 24.8 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match Tempstar in ThermalSpec's current SaferProducts feed.

Tempstar HP024V/H/C**1**1 Cohort Metrics vs. Geothermal Heat Pump Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Max COP)** | #1,503 of 1,730 (120 tied, beats 6.2% of peers) | -0.40 COP vs 4.50 COP category median |
| **Closed/Open Loop EER vs Cohort** | 24.8 EER | +0.20 EER vs 24.6 EER median |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **ENERGY STAR Most Efficient Criteria** | MOST EFFICIENT | Max COP 4.1 / Max EER 24.8 (Open Loop Water-to-Air) |
| **EPA AIM Act Refrigerant Transition** | VERIFY OEM SPEC | Dataset refrigerant: R-410A |

## How much annual energy and operating cost does Tempstar HP024V/H/C**1**1 require?

Modeled utility figures for Tempstar HP024V/H/C**1**1 (Tempstar) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max COP ratings.

Heat_kWh = 50,000 kBTU / (4.1 COP * 3.412) | Cool_kWh = 36,000 BTU * 1,000 hrs / (24.8 EER * 1,000)

50 MMBtu heating + 36k BTU cooling at US median 16.33 c/kWh

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **Ground-Source Heating Electricity** | 3,574 kWh/yr | $584/yr |
| **Ground-Source Cooling Electricity (1,000 hrs)** | 1,452 kWh/yr | $237/yr |
| **Total Annual Geothermal Operating Cost** | $821/yr | State range: $639 to $2,371 |

UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

## Which AHRI certified SKU combinations belong to Tempstar HP024V/H/C**1**1?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Tempstar HP024V/H/C**1**1 (PD ID 3845722).

| HP024V/H/C**1**1 | Matched AHRI Coil | — |  |
|---|---|---|---|

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Tempstar HP024V/H/C**1**1, review 2 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across Tempstar HP024V/H/C**1**1: headline Max COP reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Tempstar HP024V/H/C**1**1 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal Tempstar HP024V/H/C**1**1 fit** | Single-family replacement needing documented ENERGY STAR PD ID 3845722 with matching indoor air handler. |
| **Skip Tempstar HP024V/H/C**1**1 if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable geothermal heat pump models deliver similar efficiency?

Compare Tempstar HP024V/H/C**1**1 against GeoComfort GWS036* and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.

### [GeoComfort GWS036*](https://myhomeheating.org/equipment/geothermal/geocomfort/geocomfort-gws036/)

4.1 COP · 22.9 EER · 1 combos

### [GeoComfort GWT048*](https://myhomeheating.org/equipment/geothermal/geocomfort/geocomfort-gwt048/)

4.1 COP · 22.8 EER · 1 combos

### [GeoComfort GZS017*](https://myhomeheating.org/equipment/geothermal/geocomfort/geocomfort-gzs017-baefc/)

4.1 COP · 21.9 EER · 1 combos

### [GeoComfort GZS042*1B](https://myhomeheating.org/equipment/geothermal/geocomfort/geocomfort-gzs042-1b/)

4.1 COP · 21.1 EER · 1 combos

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does Tempstar HP024V/H/C**1**1 compare with peer Geothermal Heat Pump units?

Tempstar HP024V/H/C**1**1 holds #1,503 of 1,730 (120 tied, beats 6.2% of peers) out of 1,730 verified geothermal heat pump models (-0.40 COP vs 4.50 COP category median), spanning 1 certified SKU up to 4.1 COP. Closest same-cohort alternatives include GeoComfort GWS036*.

DOE Regions

### Where is Tempstar HP024V/H/C**1**1 compliant for 2026 US installation?

Tempstar HP024V/H/C**1**1: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does Tempstar HP024V/H/C**1**1 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Tempstar HP024V/H/C**1**1 runs 3,574 kWh/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does Tempstar HP024V/H/C**1**1 cover?

Tempstar HP024V/H/C**1**1 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does Tempstar HP024V/H/C**1**1 handle extreme weather or cold snaps?

Tempstar HP024V/H/C**1**1 is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern Tempstar HP024V/H/C**1**1?

Tempstar HP024V/H/C**1**1 specifies R-410A compliance (PD ID 3845722); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 1 certified SKU in Tempstar HP024V/H/C**1**1 reach 4.1 COP?

Peak 4.1 COP represents the top tested AHRI pairing for Tempstar HP024V/H/C**1**1 (PD ID 3845722); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to Tempstar HP024V/H/C**1**1?

Tempstar HP024V/H/C**1**1 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include GeoComfort GWS036*.

## Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Geothermal-Heat-Pumps/acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
4. [40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-84) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
5. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
6. [Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

[ All Tempstar Geothermal Heat Pumps (66) → ](https://myhomeheating.org/equipment/geothermal/tempstar/) [ All Geothermal Heat Pumps (1,730) → ](https://myhomeheating.org/equipment/geothermal/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare GeoComfort GWS036* (4.1 COP) → ](https://myhomeheating.org/equipment/geothermal/geocomfort/geocomfort-gws036/) [ Compare GeoComfort GWT048* (4.1 COP) → ](https://myhomeheating.org/equipment/geothermal/geocomfort/geocomfort-gwt048/) [ TETCO TVS041 → ](https://myhomeheating.org/equipment/geothermal/tetco/tetco-tvs041/) [ TETCO TVT042*1 → ](https://myhomeheating.org/equipment/geothermal/tetco/tetco-tvt042-1/) [ TETCO TZS042*1B → ](https://myhomeheating.org/equipment/geothermal/tetco/tetco-tzs042-1b/)

Tempstar Quick Spec Summary

- **Cohort Rank**: #1,503/1,730

- **Max COP**: 120 tied, more efficient than 6.2% of certified series

- **Verified SKUs**: 1

- **Brand Hub**: [Tempstar](https://myhomeheating.org/equipment/geothermal/tempstar/)

- **Category Hub**: [Geothermal Heat Pump](https://myhomeheating.org/equipment/geothermal/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).