---
title: "Miami Heat Pump HPX049 Specs: 4.1 COP (#1,503/1,730)"
url: https://myhomeheating.org/equipment/geothermal/miami-heat-pump/miami-heat-pump-hpx049/
description: "Verified ENERGY STAR specs for Miami Heat Pump HPX049 geothermal heat pump: 4.1 COP, #1,503 of 1,730, operating cost formula, and peer models."
---

Geothermal Heat Pump · Miami Heat Pump · 1 ENERGY STAR Combinations

# Miami Heat Pump HPX049 — Geothermal Heat Pump Specifications

Miami Heat Pump HPX049 (Geothermal Heat Pump, PD ID 2853332) holds 1 ENERGY STAR certified SKU rated at 4.1 COP — #1,503 of 1,730 (120 tied, beats 6.2% of peers), -0.40 COP. ENERGY STAR certified residential HVAC model. Miami Heat Pump HPX049 — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.1 COP and Cohort Rank set at #1,503/1,730.

- **Heating COP**: 4.1 COP

- **Cohort Rank**: #1,503/1,730

- **Verified Combos**: 1 SKU

- **Sample PD ID**: 2853332

Geothermal Heat Pump Efficiency Spread across 1730 certified series (3.9 to 5.7 COP)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 3.9 - 4.1 COP | 228 | This series |
| 4.1 - 4.3 COP | 329 | Peer range |
| 4.3 - 4.5 COP | 251 | Peer range |
| 4.5 - 4.7 COP | 296 | Peer range |
| 4.7 - 4.9 COP | 244 | Peer range |
| 4.9 - 5.1 COP | 310 | Peer range |
| 5.1 - 5.3 COP | 37 | Peer range |
| 5.3 - 5.5 COP | 32 | Peer range |
| 5.5 - 5.7 COP | 3 | Peer range |

Miami Heat Pump HPX049 residential equipment inspection. ThermalSpec Editorial Photography

## How does Miami Heat Pump HPX049 rank across federal compliance and ENERGY STAR cohorts?

Miami Heat Pump HPX049 ranks #1,503 of 1,730 (tied with 119 others at 4.10 COP, more efficient than 6.2% of certified series) for Max COP (-0.40 COP vs 4.50 COP category median) across 1 certified SKU combination. Open Loop Water-to-Air unit delivering 4.1 COP and 21.1 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match Miami Heat Pump in ThermalSpec's current SaferProducts feed.

Miami Heat Pump HPX049 Cohort Metrics vs. Geothermal Heat Pump Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Max COP)** | #1,503 of 1,730 (120 tied, beats 6.2% of peers) | -0.40 COP vs 4.50 COP category median |
| **Closed/Open Loop EER vs Cohort** | 21.1 EER | -3.50 EER vs 24.6 EER median |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **ENERGY STAR Most Efficient Criteria** | MOST EFFICIENT | Max COP 4.1 / Max EER 21.1 (Open Loop Water-to-Air) |
| **EPA AIM Act Refrigerant Transition** | VERIFY OEM SPEC | Dataset refrigerant: R-410A |

## How much annual energy and operating cost does Miami Heat Pump HPX049 require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Miami Heat Pump HPX049 estimates reflect 1 certified SKU combination tested under PD ID 2853332.

Heat_kWh = 50,000 kBTU / (4.1 COP * 3.412) | Cool_kWh = 36,000 BTU * 1,000 hrs / (21.1 EER * 1,000)

50 MMBtu heating + 36k BTU cooling at US median 16.33 c/kWh

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **Ground-Source Heating Electricity** | 3,574 kWh/yr | $584/yr |
| **Ground-Source Cooling Electricity (1,000 hrs)** | 1,706 kWh/yr | $279/yr |
| **Total Annual Geothermal Operating Cost** | $862/yr | State range: $672 to $2,491 |

UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

## Which AHRI certified SKU combinations belong to Miami Heat Pump HPX049?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Miami Heat Pump HPX049 (PD ID 2853332).

| HPX049 | Matched AHRI Coil | — |  |
|---|---|---|---|

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Miami Heat Pump HPX049, review 2 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across Miami Heat Pump HPX049: headline Max COP reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Miami Heat Pump HPX049 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal Miami Heat Pump HPX049 fit** | Single-family replacement needing documented ENERGY STAR PD ID 2853332 with matching indoor air handler. |
| **Skip Miami Heat Pump HPX049 if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable geothermal heat pump models deliver similar efficiency?

Compare Miami Heat Pump HPX049 against Energy Catalyst DHHP096VV and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.

### [Energy Catalyst DHHP096VV](https://myhomeheating.org/equipment/geothermal/energy-catalyst/energy-catalyst-dhhp096vv/)

4.1 COP · 17.8 EER · 1 combos

### [Enertech EWS036*](https://myhomeheating.org/equipment/geothermal/enertech/enertech-ews036/)

4.1 COP · 22.9 EER · 1 combos

### [Enertech EWT048*](https://myhomeheating.org/equipment/geothermal/enertech/enertech-ewt048/)

4.1 COP · 22.8 EER · 1 combos

### [Engineered Comfort 44VHB/VCB-19](https://myhomeheating.org/equipment/geothermal/engineered-comfort/engineered-comfort-44vhb-vcb-19/)

4.1 COP · 21.1 EER · 1 combos

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does Miami Heat Pump HPX049 compare with peer Geothermal Heat Pump units?

Miami Heat Pump HPX049 holds #1,503 of 1,730 (120 tied, beats 6.2% of peers) out of 1,730 verified geothermal heat pump models (-0.40 COP vs 4.50 COP category median), spanning 1 certified SKU up to 4.1 COP. Closest same-cohort alternatives include Energy Catalyst DHHP096VV.

DOE Regions

### Where is Miami Heat Pump HPX049 compliant for 2026 US installation?

Miami Heat Pump HPX049: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does Miami Heat Pump HPX049 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Miami Heat Pump HPX049 runs 3,574 kWh/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does Miami Heat Pump HPX049 cover?

Miami Heat Pump HPX049 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does Miami Heat Pump HPX049 handle extreme weather or cold snaps?

Miami Heat Pump HPX049 is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern Miami Heat Pump HPX049?

Miami Heat Pump HPX049 specifies R-410A compliance (PD ID 2853332); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 1 certified SKU in Miami Heat Pump HPX049 reach 4.1 COP?

Peak 4.1 COP represents the top tested AHRI pairing for Miami Heat Pump HPX049 (PD ID 2853332); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to Miami Heat Pump HPX049?

Miami Heat Pump HPX049 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Energy Catalyst DHHP096VV.

## Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Geothermal-Heat-Pumps/acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
4. [40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-84) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
5. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
6. [Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

[ All Miami Heat Pump Geothermal Heat Pumps (4) → ](https://myhomeheating.org/equipment/geothermal/miami-heat-pump/) [ All Geothermal Heat Pumps (1,730) → ](https://myhomeheating.org/equipment/geothermal/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare Energy Catalyst DHHP096VV (4.1 COP) → ](https://myhomeheating.org/equipment/geothermal/energy-catalyst/energy-catalyst-dhhp096vv/) [ Compare Enertech EWS036* (4.1 COP) → ](https://myhomeheating.org/equipment/geothermal/enertech/enertech-ews036/) [ Nordic RH75HACW-P-1T-*-SDE** → ](https://myhomeheating.org/equipment/geothermal/nordic/nordic-rh75hacw-p-1t-sde/) [ Tempstar HP024V/H/C**1**1 → ](https://myhomeheating.org/equipment/geothermal/tempstar/tempstar-hp024v-h-c-1-1/) [ TETCO TVS041 → ](https://myhomeheating.org/equipment/geothermal/tetco/tetco-tvs041/)

Miami Heat Pump Quick Spec Summary

- **Cohort Rank**: #1,503/1,730

- **Max COP**: 120 tied, more efficient than 6.2% of certified series

- **Verified SKUs**: 1

- **Brand Hub**: [Miami Heat Pump](https://myhomeheating.org/equipment/geothermal/miami-heat-pump/)

- **Category Hub**: [Geothermal Heat Pump](https://myhomeheating.org/equipment/geothermal/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).
