title: "Keeprite HW048WR********1 Specs: 4.2 COP (#1,368/1,730)"
url: https://myhomeheating.org/equipment/geothermal/keeprite/keeprite-hw048wr-1/
description: "Verified ENERGY STAR specs for Keeprite HW048WR********1 geothermal heat pump: 4.2 COP, #1,368 of 1,730, operating cost formula, and peer models."
---

Geothermal Heat Pump · Keeprite · 1 ENERGY STAR Combinations

# Keeprite HW048WR1 — Geothermal Heat Pump Specifications

Keeprite HW048WR1 (Geothermal Heat Pump, PD ID 4430059) holds 1 ENERGY STAR certified SKU rated at 4.2 COP — #1,368 of 1,730 (135 tied, beats 13.2% of peers), -0.30 COP. ENERGY STAR certified residential HVAC model. Keeprite HW048WR1 — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.2 COP and Cohort Rank set at #1,368/1,730.

- **Heating COP**: 4.2 COP

- **Cohort Rank**: #1,368/1,730

- **Verified Combos**: 1 SKU

- **Sample PD ID**: 4430059

Geothermal Heat Pump Efficiency Spread across 1730 certified series (3.9 to 5.7 COP)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 3.9 - 4.1 COP | 228 | Peer range |
| 4.1 - 4.3 COP | 329 | This series |
| 4.3 - 4.5 COP | 251 | Peer range |
| 4.5 - 4.7 COP | 296 | Peer range |
| 4.7 - 4.9 COP | 244 | Peer range |
| 4.9 - 5.1 COP | 310 | Peer range |
| 5.1 - 5.3 COP | 37 | Peer range |
| 5.3 - 5.5 COP | 32 | Peer range |
| 5.5 - 5.7 COP | 3 | Peer range |

Keeprite HW048WR1 residential equipment inspection. ThermalSpec Editorial Photography

## How does Keeprite HW048WR1 rank across federal compliance and ENERGY STAR cohorts?

Keeprite HW048WR1 ranks #1,368 of 1,730 (tied with 134 others at 4.20 COP, more efficient than 13.2% of certified series) for Max COP (-0.30 COP vs 4.50 COP category median) across 1 certified SKU combination. Open Loop Water-to-Water unit delivering 4.2 COP and 23.0 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match Keeprite in ThermalSpec's current SaferProducts feed.

Keeprite HW048WR1 Cohort Metrics vs. Geothermal Heat Pump Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Max COP)** | #1,368 of 1,730 (135 tied, beats 13.2% of peers) | -0.30 COP vs 4.50 COP category median |
| **Closed/Open Loop EER vs Cohort** | 23.0 EER | -1.60 EER vs 24.6 EER median |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **ENERGY STAR Most Efficient Criteria** | MOST EFFICIENT | Max COP 4.2 / Max EER 23.0 (Open Loop Water-to-Water) |
| **EPA AIM Act Refrigerant Transition** | VERIFY OEM SPEC | Dataset refrigerant: Other |

## How much annual energy and operating cost does Keeprite HW048WR1 require?

Annual cost outputs combine Keeprite HW048WR1's 4.2 COP rating and EIA national tariffs across single-family runtime hours.

Heat_kWh = 50,000 kBTU / (4.2 COP * 3.412) | Cool_kWh = 36,000 BTU * 1,000 hrs / (23.0 EER * 1,000)

50 MMBtu heating + 36k BTU cooling at US median 16.33 c/kWh

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **Ground-Source Heating Electricity** | 3,489 kWh/yr | $570/yr |
| **Ground-Source Cooling Electricity (1,000 hrs)** | 1,565 kWh/yr | $256/yr |
| **Total Annual Geothermal Operating Cost** | $825/yr | State range: $643 to $2,384 |

UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

## Which AHRI certified SKU combinations belong to Keeprite HW048WR1?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Keeprite HW048WR1 (PD ID 4430059).

| HW048WR1 | Matched AHRI Coil | — |  |
|---|---|---|---|

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Keeprite HW048WR1, review 2 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across Keeprite HW048WR1: headline Max COP reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Keeprite HW048WR1 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal Keeprite HW048WR1 fit** | Single-family replacement needing documented ENERGY STAR PD ID 4430059 with matching indoor air handler. |
| **Skip Keeprite HW048WR1 if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable geothermal heat pump models deliver similar efficiency?

Compare Keeprite HW048WR1 against Energy Catalyst DHHP048TV and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.

### [Energy Catalyst DHHP048TV](https://myhomeheating.org/equipment/geothermal/energy-catalyst/energy-catalyst-dhhp048tv/)

4.2 COP · 19.8 EER · 1 combos

### [Enertech EBT072*](https://myhomeheating.org/equipment/geothermal/enertech/enertech-ebt072/)

4.2 COP · 22.5 EER · 1 combos

### [Enertech EWS048*](https://myhomeheating.org/equipment/geothermal/enertech/enertech-ews048/)

4.2 COP · 22.9 EER · 1 combos

### [Enertech EZT072*](https://myhomeheating.org/equipment/geothermal/enertech/enertech-ezt072/)

4.2 COP · 22.0 EER · 1 combos

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does Keeprite HW048WR1 compare with peer Geothermal Heat Pump units?

Keeprite HW048WR1 holds #1,368 of 1,730 (135 tied, beats 13.2% of peers) out of 1,730 verified geothermal heat pump models (-0.30 COP vs 4.50 COP category median), spanning 1 certified SKU up to 4.2 COP. Closest same-cohort alternatives include Energy Catalyst DHHP048TV.

DOE Regions

### Where is Keeprite HW048WR1 compliant for 2026 US installation?

Keeprite HW048WR1: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does Keeprite HW048WR1 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Keeprite HW048WR1 runs 3,489 kWh/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does Keeprite HW048WR1 cover?

Keeprite HW048WR1 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does Keeprite HW048WR1 handle extreme weather or cold snaps?

Keeprite HW048WR1 is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern Keeprite HW048WR1?

Keeprite HW048WR1 specifies Other compliance (PD ID 4430059); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 1 certified SKU in Keeprite HW048WR1 reach 4.2 COP?

Peak 4.2 COP represents the top tested AHRI pairing for Keeprite HW048WR1 (PD ID 4430059); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to Keeprite HW048WR1?

Keeprite HW048WR1 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Energy Catalyst DHHP048TV.

## Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Geothermal-Heat-Pumps/acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
4. [40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-84) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
5. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
6. [Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

[ All Keeprite Geothermal Heat Pumps (64) → ](https://myhomeheating.org/equipment/geothermal/keeprite/) [ All Geothermal Heat Pumps (1,730) → ](https://myhomeheating.org/equipment/geothermal/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare Energy Catalyst DHHP048TV (4.2 COP) → ](https://myhomeheating.org/equipment/geothermal/energy-catalyst/energy-catalyst-dhhp048tv/) [ Compare Enertech EBT072* (4.2 COP) → ](https://myhomeheating.org/equipment/geothermal/enertech/enertech-ebt072/) [ Nordic TF75HACW-P-1T-*-SDE** → ](https://myhomeheating.org/equipment/geothermal/nordic/nordic-tf75hacw-p-1t-sde/) [ Tempstar HP036V/H/C**1**1 → ](https://myhomeheating.org/equipment/geothermal/tempstar/tempstar-hp036v-h-c-1-1/) [ Tempstar HP060V/H/C**N***1**1 → ](https://myhomeheating.org/equipment/geothermal/tempstar/tempstar-hp060v-h-c-n-1-1/)

Keeprite Quick Spec Summary

- **Cohort Rank**: #1,368/1,730

- **Max COP**: 135 tied, more efficient than 13.2% of certified series

- **Verified SKUs**: 1

- **Brand Hub**: [Keeprite](https://myhomeheating.org/equipment/geothermal/keeprite/)

- **Category Hub**: [Geothermal Heat Pump](https://myhomeheating.org/equipment/geothermal/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).