title: "Hydron Module HVS030 Specs: 4.7 COP (#471/1,730)"
url: https://myhomeheating.org/equipment/geothermal/hydron-module/hydron-module-hvs030/
description: "Verified ENERGY STAR specs for Hydron Module HVS030 geothermal heat pump: 4.7 COP, #471 of 1,730, operating cost formula, and peer models."
---

Geothermal Heat Pump · Hydron Module · 1 ENERGY STAR Combinations

# Hydron Module HVS030 — Geothermal Heat Pump Specifications

Hydron Module HVS030 (Geothermal Heat Pump, PD ID 2635462) holds 1 ENERGY STAR certified SKU rated at 4.7 COP — #471 of 1,730 (Top 36.2%, 156 tied), +0.20 COP. ENERGY STAR certified residential HVAC model. Hydron Module HVS030 — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.7 COP and Cohort Rank set at #471/1,730.

- **Heating COP**: 4.7 COP

- **Cohort Rank**: #471/1,730

- **Verified Combos**: 1 SKU

- **Sample PD ID**: 2635462

Geothermal Heat Pump Efficiency Spread across 1730 certified series (3.9 to 5.7 COP)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 3.9 - 4.1 COP | 228 | Peer range |
| 4.1 - 4.3 COP | 329 | Peer range |
| 4.3 - 4.5 COP | 251 | Peer range |
| 4.5 - 4.7 COP | 296 | Peer range |
| 4.7 - 4.9 COP | 244 | This series |
| 4.9 - 5.1 COP | 310 | Peer range |
| 5.1 - 5.3 COP | 37 | Peer range |
| 5.3 - 5.5 COP | 32 | Peer range |
| 5.5 - 5.7 COP | 3 | Peer range |

Hydron Module HVS030 residential equipment inspection. ThermalSpec Editorial Photography

## How does Hydron Module HVS030 rank across federal compliance and ENERGY STAR cohorts?

Hydron Module HVS030 ranks #471 of 1,730 (tied with 155 others at 4.70 COP, top 36.2%, more efficient than 63.8% of certified series) for Max COP (+0.20 COP vs 4.50 COP category median) across 1 certified SKU combination. Open Loop Water-to-Air unit delivering 4.7 COP and 23.4 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match Hydron Module in ThermalSpec's current SaferProducts feed.

Hydron Module HVS030 Cohort Metrics vs. Geothermal Heat Pump Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Max COP)** | #471 of 1,730 (Top 36.2%, 156 tied) | +0.20 COP vs 4.50 COP category median |
| **Closed/Open Loop EER vs Cohort** | 23.4 EER | -1.20 EER vs 24.6 EER median |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **ENERGY STAR Most Efficient Criteria** | MOST EFFICIENT | Max COP 4.7 / Max EER 23.4 (Open Loop Water-to-Air) |
| **EPA AIM Act Refrigerant Transition** | VERIFY OEM SPEC | Dataset refrigerant: R-410A |

## How much annual energy and operating cost does Hydron Module HVS030 require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Hydron Module HVS030 estimates reflect 1 certified SKU combination tested under PD ID 2635462.

Heat_kWh = 50,000 kBTU / (4.7 COP * 3.412) | Cool_kWh = 36,000 BTU * 1,000 hrs / (23.4 EER * 1,000)

50 MMBtu heating + 36k BTU cooling at US median 16.33 c/kWh

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **Ground-Source Heating Electricity** | 3,118 kWh/yr | $509/yr |
| **Ground-Source Cooling Electricity (1,000 hrs)** | 1,538 kWh/yr | $251/yr |
| **Total Annual Geothermal Operating Cost** | $760/yr | State range: $592 to $2,197 |

UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

## Which AHRI certified SKU combinations belong to Hydron Module HVS030?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Hydron Module HVS030 (PD ID 2635462).

| HVS030 | Matched AHRI Coil | — |  |
|---|---|---|---|

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Hydron Module HVS030, review 2 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across Hydron Module HVS030: headline Max COP reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Hydron Module HVS030 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal Hydron Module HVS030 fit** | Single-family replacement needing documented ENERGY STAR PD ID 2635462 with matching indoor air handler. |
| **Skip Hydron Module HVS030 if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable geothermal heat pump models deliver similar efficiency?

Compare Hydron Module HVS030 against GeoComfort GVS042 and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.

### [GeoComfort GVS042](https://myhomeheating.org/equipment/geothermal/geocomfort/geocomfort-gvs042/)

4.7 COP · 24.4 EER · 1 combos

### [GeoComfort GVT030*](https://myhomeheating.org/equipment/geothermal/geocomfort/geocomfort-gvt030/)

4.7 COP · 26.8 EER · 2 combos

### [GeoComfort GVT036](https://myhomeheating.org/equipment/geothermal/geocomfort/geocomfort-gvt036/)

4.7 COP · 26.3 EER · 2 combos

### [GeoComfort GVT036*](https://myhomeheating.org/equipment/geothermal/geocomfort/geocomfort-gvt036-dbd18/)

4.7 COP · 26.3 EER · 2 combos

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does Hydron Module HVS030 compare with peer Geothermal Heat Pump units?

Hydron Module HVS030 holds #471 of 1,730 (Top 36.2%, 156 tied) out of 1,730 verified geothermal heat pump models (+0.20 COP vs 4.50 COP category median), spanning 1 certified SKU up to 4.7 COP. Closest same-cohort alternatives include GeoComfort GVS042.

DOE Regions

### Where is Hydron Module HVS030 compliant for 2026 US installation?

Hydron Module HVS030: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does Hydron Module HVS030 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Hydron Module HVS030 runs 3,118 kWh/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does Hydron Module HVS030 cover?

Hydron Module HVS030 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does Hydron Module HVS030 handle extreme weather or cold snaps?

Hydron Module HVS030 is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern Hydron Module HVS030?

Hydron Module HVS030 specifies R-410A compliance (PD ID 2635462); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 1 certified SKU in Hydron Module HVS030 reach 4.7 COP?

Peak 4.7 COP represents the top tested AHRI pairing for Hydron Module HVS030 (PD ID 2635462); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to Hydron Module HVS030?

Hydron Module HVS030 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include GeoComfort GVS042.

## Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Geothermal-Heat-Pumps/acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
4. [40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-84) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
5. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
6. [Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

[ All Hydron Module Geothermal Heat Pumps (96) → ](https://myhomeheating.org/equipment/geothermal/hydron-module/) [ All Geothermal Heat Pumps (1,730) → ](https://myhomeheating.org/equipment/geothermal/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare GeoComfort GVS042 (4.7 COP) → ](https://myhomeheating.org/equipment/geothermal/geocomfort/geocomfort-gvs042/) [ Compare GeoComfort GVT030* (4.7 COP) → ](https://myhomeheating.org/equipment/geothermal/geocomfort/geocomfort-gvt030/) [ Hydron Module HVS042 → ](https://myhomeheating.org/equipment/geothermal/hydron-module/hydron-module-hvs042/) [ Hydron Module HZS015 → ](https://myhomeheating.org/equipment/geothermal/hydron-module/hydron-module-hzs015/) [ Hydron Module HZS017*1 → ](https://myhomeheating.org/equipment/geothermal/hydron-module/hydron-module-hzs017-1/)

Hydron Module Quick Spec Summary

- **Cohort Rank**: #471/1,730

- **Max COP**: top 36.2%, 156 tied

- **Verified SKUs**: 1

- **Brand Hub**: [Hydron Module](https://myhomeheating.org/equipment/geothermal/hydron-module/)

- **Category Hub**: [Geothermal Heat Pump](https://myhomeheating.org/equipment/geothermal/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).