title: "Climatemaster SJ/PN024A Specs: 4.9 COP (#281/1,730)"
url: https://myhomeheating.org/equipment/geothermal/climatemaster/climatemaster-sj-pn024a/
description: "Verified ENERGY STAR specs for Climatemaster SJ/PN024A geothermal heat pump: 4.9 COP, #281 of 1,730, operating cost formula, and peer models."
---

Geothermal Heat Pump · Climatemaster · 4 ENERGY STAR Combinations

# Climatemaster SJ/PN024A — Geothermal Heat Pump Specifications

Climatemaster SJ/PN024A (Geothermal Heat Pump, PD ID 3891800) holds 4 ENERGY STAR certified SKUs rated at 4.9 COP — #281 of 1,730 (Top 22.1%, 102 tied), +0.40 COP. ENERGY STAR certified residential HVAC model. Climatemaster SJ/PN024A — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.9 COP and Cohort Rank set at #281/1,730.

- **Heating COP**: 4.9 COP

- **Cohort Rank**: #281/1,730

- **Verified Combos**: 4 SKUs

- **Sample PD ID**: 3891800

Geothermal Heat Pump Efficiency Spread across 1730 certified series (3.9 to 5.7 COP)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 3.9 - 4.1 COP | 228 | Peer range |
| 4.1 - 4.3 COP | 329 | Peer range |
| 4.3 - 4.5 COP | 251 | Peer range |
| 4.5 - 4.7 COP | 296 | Peer range |
| 4.7 - 4.9 COP | 244 | Peer range |
| 4.9 - 5.1 COP | 310 | This series |
| 5.1 - 5.3 COP | 37 | Peer range |
| 5.3 - 5.5 COP | 32 | Peer range |
| 5.5 - 5.7 COP | 3 | Peer range |

Climatemaster SJ/PN024A residential equipment inspection. ThermalSpec Editorial Photography

## How does Climatemaster SJ/PN024A rank across federal compliance and ENERGY STAR cohorts?

Climatemaster SJ/PN024A ranks #281 of 1,730 (tied with 101 others at 4.90 COP, top 22.1%, more efficient than 77.9% of certified series) for Max COP (+0.40 COP vs 4.50 COP category median) across 4 certified SKU combinations. Open Loop Water-to-Air unit delivering 4.9 COP and 27.7 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match Climatemaster in ThermalSpec's current SaferProducts feed.

Climatemaster SJ/PN024A Cohort Metrics vs. Geothermal Heat Pump Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Max COP)** | #281 of 1,730 (Top 22.1%, 102 tied) | +0.40 COP vs 4.50 COP category median |
| **Closed/Open Loop EER vs Cohort** | 27.7 EER | +3.10 EER vs 24.6 EER median |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **ENERGY STAR Most Efficient Criteria** | MOST EFFICIENT | Max COP 4.9 / Max EER 27.7 (Open Loop Water-to-Air) |
| **EPA AIM Act Refrigerant Transition** | VERIFY OEM SPEC | Dataset refrigerant: Other |

## How much annual energy and operating cost does Climatemaster SJ/PN024A require?

Annual cost outputs combine Climatemaster SJ/PN024A's 4.9 COP rating and EIA national tariffs across single-family runtime hours.

Heat_kWh = 50,000 kBTU / (4.9 COP * 3.412) | Cool_kWh = 36,000 BTU * 1,000 hrs / (27.7 EER * 1,000)

50 MMBtu heating + 36k BTU cooling at US median 16.33 c/kWh

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **Ground-Source Heating Electricity** | 2,991 kWh/yr | $488/yr |
| **Ground-Source Cooling Electricity (1,000 hrs)** | 1,300 kWh/yr | $212/yr |
| **Total Annual Geothermal Operating Cost** | $701/yr | State range: $546 to $2,024 |

UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

## Which AHRI certified SKU combinations belong to Climatemaster SJ/PN024A?

Showing 4 certified indoor-outdoor coil combinations from 4 total AHRI matched records filed for Climatemaster SJ/PN024A (PD ID 3891800).

| SJ/PN024A | Matched AHRI Coil | — |  |
|---|---|---|---|
| SJ/PN024A | Matched AHRI Coil | — |  |
| SJ/PN024A | Matched AHRI Coil | — |  |
| SJ/PN024A | Matched AHRI Coil | — |  |

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Climatemaster SJ/PN024A, review 2 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across Climatemaster SJ/PN024A: headline Max COP reflects peak tested matches among 4 SKUs, not lower-rated sizes.
- Catalog specs for Climatemaster SJ/PN024A exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal Climatemaster SJ/PN024A fit** | Single-family replacement needing documented ENERGY STAR PD ID 3891800 with matching indoor air handler. |
| **Skip Climatemaster SJ/PN024A if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable geothermal heat pump models deliver similar efficiency?

Compare Climatemaster SJ/PN024A against Arcoaire HB036V**1**1 and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.

### [Arcoaire HB036V**1**1](https://myhomeheating.org/equipment/geothermal/arcoaire/arcoaire-hb036v-1-1/)

4.9 COP · 25.9 EER · 1 combos

### [Arcoaire HCR24H**C**1](https://myhomeheating.org/equipment/geothermal/arcoaire/arcoaire-hcr24h-c-1/)

4.9 COP · 27.8 EER · 2 combos

### [Arcoaire HCR24H**N**1](https://myhomeheating.org/equipment/geothermal/arcoaire/arcoaire-hcr24h-n-1/)

4.9 COP · 27.8 EER · 2 combos

### [Arcoaire HCR24V**C**1](https://myhomeheating.org/equipment/geothermal/arcoaire/arcoaire-hcr24v-c-1/)

4.9 COP · 27.8 EER · 2 combos

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does Climatemaster SJ/PN024A compare with peer Geothermal Heat Pump units?

Climatemaster SJ/PN024A holds #281 of 1,730 (Top 22.1%, 102 tied) out of 1,730 verified geothermal heat pump models (+0.40 COP vs 4.50 COP category median), spanning 4 certified SKUs up to 4.9 COP. Closest same-cohort alternatives include Arcoaire HB036V**1**1.

DOE Regions

### Where is Climatemaster SJ/PN024A compliant for 2026 US installation?

Climatemaster SJ/PN024A: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does Climatemaster SJ/PN024A model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Climatemaster SJ/PN024A runs 2,991 kWh/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does Climatemaster SJ/PN024A cover?

Climatemaster SJ/PN024A covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does Climatemaster SJ/PN024A handle extreme weather or cold snaps?

Climatemaster SJ/PN024A is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern Climatemaster SJ/PN024A?

Climatemaster SJ/PN024A specifies Other compliance (PD ID 3891800); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 4 certified SKUs in Climatemaster SJ/PN024A reach 4.9 COP?

Peak 4.9 COP represents the top tested AHRI pairing for Climatemaster SJ/PN024A (PD ID 3891800); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to Climatemaster SJ/PN024A?

Climatemaster SJ/PN024A requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Arcoaire HB036V**1**1.

## Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Geothermal-Heat-Pumps/acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
4. [40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-84) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
5. [UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance](https://www.ul.com/services/a2l-refrigerants-testing-and-certification) — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
6. [Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

[ All Climatemaster Geothermal Heat Pumps (35) → ](https://myhomeheating.org/equipment/geothermal/climatemaster/) [ All Geothermal Heat Pumps (1,730) → ](https://myhomeheating.org/equipment/geothermal/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare Arcoaire HB036V**1**1 (4.9 COP) → ](https://myhomeheating.org/equipment/geothermal/arcoaire/arcoaire-hb036v-1-1/) [ Compare Arcoaire HCR24H**C**1 (4.9 COP) → ](https://myhomeheating.org/equipment/geothermal/arcoaire/arcoaire-hcr24h-c-1/) [ Comfort-Aire MJN024A → ](https://myhomeheating.org/equipment/geothermal/comfort-aire/comfort-aire-mjn024a/) [ GeoStar 103J036**1 → ](https://myhomeheating.org/equipment/geothermal/geostar/geostar-103j036-1/) [ York QZ048-1CSC-*A → ](https://myhomeheating.org/equipment/geothermal/york/york-qz048-1csc-a/)

Climatemaster Quick Spec Summary

- **Cohort Rank**: #281/1,730

- **Max COP**: top 22.1%, 102 tied

- **Verified SKUs**: 4

- **Brand Hub**: [Climatemaster](https://myhomeheating.org/equipment/geothermal/climatemaster/)

- **Category Hub**: [Geothermal Heat Pump](https://myhomeheating.org/equipment/geothermal/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).