# Bryant Geothermal Heat Pumps — ENERGY STAR Certified Models

Bryant certifies 76 geothermal heat pumps models across 118 AHRI combinations, led by GZ036SA*C**1 at 5.1 COP against the 4.5 COP category median across Residential capacities. Bryant Geothermal Heat Pumps — ENERGY STAR Certified Models benchmarks residential systems using Certified Models set at 76 and Rating Span set at 4.1 COP - 5.1 COP.

- **Certified Models**: 76

- **Rating Span**: 4.1 COP - 5.1 COP

- **Capacity Range**: Residential capacities

- **AHRI Combinations**: 118

- **Cold Climate Units**: 0

- **Category Median**: 4.5 COP

Bryant Geothermal Heat Pumps — ENERGY STAR Certified Models editorial reference. ThermalSpec Editorial Photography

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).

## How does Bryant's geothermal heat pumps portfolio cover capacity, refrigerants, and safety?

Bryant covers Residential capacities in geothermal heat pumps across 76 canonical models and 118 AHRI combinations, with 0 Cold Climate certified models and Other, R-410A. Ratings span 4.1 COP up to 5.1 COP (category median 4.5 COP, certified through 2025-06-06). CPSC records show 2 residential HVAC recall notices matching Bryant; check exact AHRI matched pairings on individual model sheets.

Filter this directory

Showing **76** entries

## Which verified records belong in Bryant Geothermal Heat Pumps — ENERGY STAR Certified Models?

Compare all 76 verified entries below. Click any column header to sort numerically or alphabetically, then select any row for full benchmark citations.

All 76 ENERGY STAR Bryant Geothermal Heat Pumps Models

| [Bryant GZ036SA*C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz036sa-c-1/) | 4.7 COP | 25.5 EER | Open Loop Water-to-Air | 5 |
|---|---|---|---|---|
| [Bryant GZ024SA*C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz024sa-c-1/) | 5.0 COP | 27.3 EER | Open Loop Water-to-Air | 4 |
| [Bryant GZ048SA*C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz048sa-c-1/) | 4.7 COP | 24.7 EER | Open Loop Water-to-Air | 4 |
| [Bryant GZ036SA*N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz036sa-n-1/) | 4.6 COP | 25.0 EER | Open Loop Water-to-Air | 4 |
| [Bryant GZ024SA*N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz024sa-n-1/) | 4.9 COP | 26.8 EER | Open Loop Water-to-Air | 3 |
| [Bryant GZ048SA*N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz048sa-n-1/) | 4.6 COP | 24.2 EER | Open Loop Water-to-Air | 3 |
| [Bryant GZ060SA*C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz060sa-c-1/) | 4.5 COP | 24.6 EER | Open Loop Water-to-Air | 3 |
| [Bryant GC048H**C***1*X1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gc048h-c-1-x1/) | 5.1 COP | 28.1 EER | Open Loop Water-to-Air | 2 |
| [Bryant GCA36V/H**C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gca36v-h-c-1/) | 5.1 COP | 27.0 EER | Open Loop Water-to-Air | 2 |
| [Bryant GCA36V/H**N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gca36v-h-n-1/) | 5.1 COP | 26.5 EER | Open Loop Water-to-Air | 2 |
| [Bryant GCA48V/H**C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gca48v-h-c-1/) | 5.1 COP | 26.3 EER | Open Loop Water-to-Air | 2 |
| [Bryant GCA48V/H**N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gca48v-h-n-1/) | 5.1 COP | 25.8 EER | Open Loop Water-to-Air | 2 |
| [Bryant GCA60V/H**C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gca60v-h-c-1/) | 5.1 COP | 27.3 EER | Open Loop Water-to-Air | 2 |
| [Bryant GCA60V/H**N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gca60v-h-n-1/) | 5.1 COP | 26.8 EER | Open Loop Water-to-Air | 2 |
| [Bryant GB042H**1**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gb042h-1-1/) | 5.0 COP | 27.2 EER | Open Loop Water-to-Air | 2 |
| [Bryant GC048H**N***1*X1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gc048h-n-1-x1/) | 4.9 COP | 27.3 EER | Open Loop Water-to-Air | 2 |
| [Bryant GCA24H**C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gca24h-c-1/) | 4.9 COP | 27.8 EER | Open Loop Water-to-Air | 2 |
| [Bryant GCA24H**N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gca24h-n-1/) | 4.9 COP | 27.8 EER | Open Loop Water-to-Air | 2 |
| [Bryant GCA24V**C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gca24v-c-1/) | 4.9 COP | 27.8 EER | Open Loop Water-to-Air | 2 |
| [Bryant GCA24V**N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gca24v-n-1/) | 4.9 COP | 27.8 EER | Open Loop Water-to-Air | 2 |
| [Bryant GC036C/H/V**1*X1 + UI](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gc036c-h-v-1-x1-ui/) | 4.6 COP | 29.6 EER | Open Loop Water-to-Air | 2 |
| [Bryant GC048V/C**C***1*X1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gc048v-c-c-1-x1/) | 4.6 COP | 27.4 EER | Open Loop Water-to-Air | 2 |
| [Bryant GCA72H**C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gca72h-c-1/) | 4.6 COP | 24.5 EER | Open Loop Water-to-Air | 2 |
| [Bryant GCA72H**N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gca72h-n-1/) | 4.6 COP | 24.0 EER | Open Loop Water-to-Air | 2 |
| [Bryant GCA72V**C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gca72v-c-1/) | 4.6 COP | 24.5 EER | Open Loop Water-to-Air | 2 |
| [Bryant GCA72V**N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gca72v-n-1/) | 4.6 COP | 24.0 EER | Open Loop Water-to-Air | 2 |
| [Bryant GZ060SA*N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz060sa-n-1/) | 4.4 COP | 24.2 EER | Open Loop Water-to-Air | 2 |
| [Bryant GZ036***N***1**2](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz036-n-1-2/) | 4.3 COP | 23.1 EER | Open Loop Water-to-Air | 2 |
| [Bryant GZ072SA*C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz072sa-c-1/) | 4.2 COP | 23.3 EER | Open Loop Water-to-Air | 2 |
| [Bryant GZ072SA*N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz072sa-n-1/) | 4.1 COP | 22.9 EER | Open Loop Water-to-Air | 2 |
| [Bryant GC024H**C***1*X1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gc024h-c-1-x1/) | 5.1 COP | 28.8 EER | Open Loop Water-to-Air | 1 |
| [Bryant GC024H**N***1*X1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gc024h-n-1-x1/) | 5.1 COP | 27.0 EER | Open Loop Water-to-Air | 1 |
| [Bryant GB030H/V**1*X1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gb030h-v-1-x1/) | 5.0 COP | 27.0 EER | Open Loop Water-to-Air | 1 |
| [Bryant GB036V**1**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gb036v-1-1/) | 4.9 COP | 25.9 EER | Open Loop Water-to-Air | 1 |
| [Bryant GB036H**1**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gb036h-1-1/) | 4.7 COP | 24.3 EER | Open Loop Water-to-Air | 1 |
| [Bryant GB042V**1**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gb042v-1-1/) | 4.7 COP | 25.6 EER | Open Loop Water-to-Air | 1 |
| [Bryant GC024V/C**N***1*X1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gc024v-c-n-1-x1/) | 4.6 COP | 26.9 EER | Open Loop Water-to-Air | 1 |
| [Bryant GZ036***C***1**2](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz036-c-1-2/) | 4.6 COP | 24.2 EER | Open Loop Water-to-Air | 1 |
| [Bryant GB024H/V**1*X1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gb024h-v-1-x1/) | 4.5 COP | 27.4 EER | Open Loop Water-to-Air | 1 |
| [Bryant GB048H**1**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gb048h-1-1/) | 4.5 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| [Bryant GC024V/C**C***1*X1 + UI](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gc024v-c-c-1-x1-ui/) | 4.5 COP | 28.8 EER | Open Loop Water-to-Air | 1 |
| [Bryant GC060C/H/V**1*X1 + UI](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gc060c-h-v-1-x1-ui/) | 4.5 COP | 25.8 EER | Open Loop Water-to-Air | 1 |
| [Bryant GB018H**1**2](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gb018h-1-2/) | 4.4 COP | 24.7 EER | Open Loop Water-to-Air | 1 |
| [Bryant GB018V**1**2](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gb018v-1-2/) | 4.4 COP | 25.3 EER | Open Loop Water-to-Air | 1 |
| [Bryant GBA18V/H**C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gba18v-h-c-1/) | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| [Bryant GBA18V/H**N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gba18v-h-n-1/) | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| [Bryant GBA36V/H**C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gba36v-h-c-1/) | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| [Bryant GBA36V/H**N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gba36v-h-n-1/) | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| [Bryant GBA42V/H**C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gba42v-h-c-1/) | 4.4 COP | 23.5 EER | Open Loop Water-to-Air | 1 |
| [Bryant GBA42V/H**N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gba42v-h-n-1/) | 4.4 COP | 23.5 EER | Open Loop Water-to-Air | 1 |
| [Bryant GBA48V/H**C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gba48v-h-c-1/) | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| [Bryant GBA48V/H**N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gba48v-h-n-1/) | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| [Bryant GBA60V/H**C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gba60v-h-c-1/) | 4.4 COP | 23.3 EER | Open Loop Water-to-Air | 1 |
| [Bryant GBA60V/H**N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gba60v-h-n-1/) | 4.4 COP | 23.3 EER | Open Loop Water-to-Air | 1 |
| [Bryant GC048V/C**N***1*X1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gc048v-c-n-1-x1/) | 4.4 COP | 27.0 EER | Open Loop Water-to-Air | 1 |
| [Bryant GC072C/H/V**1*X1 + UI](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gc072c-h-v-1-x1-ui/) | 4.4 COP | 23.8 EER | Open Loop Water-to-Air | 1 |
| [Bryant GP048V/H/C**1**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gp048v-h-c-1-1/) | 4.4 COP | 21.5 EER | Open Loop Water-to-Air | 1 |
| [Bryant GZ024***1**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz024-1-1/) | 4.4 COP | 24.8 EER | Open Loop Water-to-Air | 1 |
| [Bryant GZ036***1**2](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz036-1-2/) | 4.4 COP | 23.6 EER | Open Loop Water-to-Air | 1 |
| [Bryant GB048V**1**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gb048v-1-1/) | 4.3 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| [Bryant GBA24V/H**C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gba24v-h-c-1/) | 4.3 COP | 25.0 EER | Open Loop Water-to-Air | 1 |
| [Bryant GBA24V/H**N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gba24v-h-n-1/) | 4.3 COP | 25.0 EER | Open Loop Water-to-Air | 1 |
| [Bryant GBA30V/H**C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gba30v-h-c-1/) | 4.3 COP | 24.5 EER | Open Loop Water-to-Air | 1 |
| [Bryant GBA30V/H**N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gba30v-h-n-1/) | 4.3 COP | 24.3 EER | Open Loop Water-to-Air | 1 |
| [Bryant GP060H**C***1**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gp060h-c-1-1/) | 4.3 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| [Bryant GP060V**C***1**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gp060v-c-1-1/) | 4.3 COP | 22.9 EER | Open Loop Water-to-Air | 1 |
| [Bryant GP036V/H/C**1**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gp036v-h-c-1-1/) | 4.2 COP | 24.3 EER | Open Loop Water-to-Air | 1 |
| [Bryant GP060V/H/C**N***1**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gp060v-h-c-n-1-1/) | 4.2 COP | 23.5 EER | Open Loop Water-to-Air | 1 |
| [Bryant GW024WA1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gw024wa-1/) | 4.2 COP | 26.8 EER | Open Loop Water-to-Water | 1 |
| [Bryant GW048WA1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gw048wa-1/) | 4.2 COP | 23.0 EER | Open Loop Water-to-Water | 1 |
| [Bryant GZ048***1**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz048-1-1/) | 4.2 COP | 22.4 EER | Open Loop Water-to-Air | 1 |
| [Bryant GZ060***1**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz060-1-1/) | 4.2 COP | 22.6 EER | Open Loop Water-to-Air | 1 |
| [Bryant GZ072***1**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz072-1-1/) | 4.2 COP | 22.3 EER | Open Loop Water-to-Air | 1 |
| [Bryant GBA70H**N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gba70h-n-1/) | 4.1 COP | 21.1 EER | Open Loop Water-to-Air | 1 |
| [Bryant GP024V/H/C**1**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gp024v-h-c-1-1/) | 4.1 COP | 24.8 EER | Open Loop Water-to-Air | 1 |
| [Bryant GP072V/H/C**1**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gp072v-h-c-1-1/) | 4.1 COP | 22.4 EER | Open Loop Water-to-Air | 1 |

## Which top Bryant geothermal heat pumps anchor this lineup?

Select any of the 4 verified listings below to open detailed specifications, safety boundaries, and source links.

Bryant4.7 COP

### [Bryant GZ036SA*C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz036sa-c-1/)

25.5 EER | Open Loop Water-to-Air | 5 SKUs

PD ID 4429867 [Inspect](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz036sa-c-1/)

Bryant5.0 COP

### [Bryant GZ024SA*C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz024sa-c-1/)

27.3 EER | Open Loop Water-to-Air | 4 SKUs

PD ID 4429863 [Inspect](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz024sa-c-1/)

Bryant4.7 COP

### [Bryant GZ048SA*C**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz048sa-c-1/)

24.7 EER | Open Loop Water-to-Air | 4 SKUs

PD ID 4429869 [Inspect](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz048sa-c-1/)

Bryant4.6 COP

### [Bryant GZ036SA*N**1](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz036sa-n-1/)

25.0 EER | Open Loop Water-to-Air | 4 SKUs

PD ID 4429868 [Inspect](https://myhomeheating.org/equipment/geothermal/bryant/bryant-gz036sa-n-1/)

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Bryant Geothermal Heat Pumps, review 3 important real-world limits and verify local licensing and permit rules directly.

- Cohort spread across Bryant: 4.1 COP entry units differ substantially from flagship GZ036SA*C**1 (5.1 COP).
- Verify indoor coil AHRI pairing on PD ID 4429867 and 3845903 before pulling state mechanical permits.
- Equipment catalog metrics exclude ductwork upgrades, A2L leak sensors where applicable, and municipal inspection fees.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Best fit for Bryant** | Homes matched to Residential capacities seeking Other, R-410A compliance and verified ENERGY STAR documentation. |
| **Skip or verify further if** | Existing ductwork pushes total static pressure above 0.50 in. w.c. or 3-phase commercial wiring is present. |

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Bryant Peak

### Which Bryant geothermal heat pumps model reaches the highest 5.1 COP rating?

GZ036SA*C**1 tops Bryant's 76 ENERGY STAR geothermal heat pumps models at 5.1 COP across 5 AHRI matches (PD ID 4429867).

Lineup Span

### How broad is Bryant's geothermal heat pumps efficiency and BTU range?

Bryant spans 4.1 COP (GP072V/H/C**1**1) up to 5.1 COP (GZ036SA*C**1) across Residential capacities, compared with the 4.5 COP category median.

AHRI Pairs

### How many AHRI combinations support Bryant geothermal heat pumps?

Current ENERGY STAR datasets document 118 verified indoor-outdoor AHRI combinations distributed across 76 canonical Bryant models.

Cold / Fuel

### What refrigerants or fuels power Bryant geothermal heat pumps?

Bryant geothermal heat pumps listings record Other, R-410A, with 0 Cold Climate certified models inside the geothermal heat pumps cohort.

DOE Regions

### Where are Bryant geothermal heat pumps compliant under 2026 federal rules?

Models meeting 13.4 SEER2 qualify in the North; 14.3 SEER2 (plus 11.7 EER2 or 9.8 at 15.2+ SEER2) is needed for Southwest split cooling, while split heat pumps require 14.3 SEER2 / 7.5 HSPF2 nationwide.

CPSC Recalls

### Are any CPSC safety recalls linked to Bryant residential HVAC products?

ThermalSpec counts 2 residential HVAC CPSC filings referencing Bryant; verify model serial prefixes at /recalls/ before installation or service.

 25C Tax Credit

### Do Bryant geothermal heat pumps receive federal Section 25C credits in 2026?

No — IRS Section 25C credits terminated December 31, 2025 ($0 federal tax credit for Bryant in 2026). Check state HOMES/HEAR and local utility ENERGY STAR rebates using PD ID 4429867.

Sizing Rule

### How should homeowners select among Bryant's 76 geothermal heat pumps models?

Match Bryant model capacity (Residential capacities) using an ACCA Manual J room-by-room heat load and <= 0.50 in. w.c. static pressure check rather than old unit tonnage.

## Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Geothermal-Heat-Pumps/acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-84) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
4. [Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 6 pages.

[ All Geothermal Heat Pumps Brands (45) → ](https://myhomeheating.org/equipment/geothermal/) [ Check 51-State DOE Minimum SEER2 Rules → ](https://myhomeheating.org/states/) [ Heat Pump vs. Gas Operating Calculator → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Carrier Geothermal Heat Pumps — ENERGY STAR Certified Mode → ](https://myhomeheating.org/equipment/geothermal/carrier/) [ WaterFurnace Geothermal Heat Pumps — ENERGY STAR Certified → ](https://myhomeheating.org/equipment/geothermal/waterfurnace/) [ Tempstar Geothermal Heat Pumps — ENERGY STAR Certified Mod → ](https://myhomeheating.org/equipment/geothermal/tempstar/)