---
title: "Keeprite G97CTN0601716A Specs: 97.0% AFUE (#167/3,740)"
url: https://myhomeheating.org/equipment/furnaces/keeprite/keeprite-g97ctn0601716a/
description: "Verified ENERGY STAR specs for Keeprite G97CTN0601716A residential furnace: 97.0% AFUE, #167 of 3,740, operating cost formula, and peer models."
---

Residential Furnace · Keeprite · 1 ENERGY STAR Combinations

# Keeprite G97CTN0601716A — Residential Furnace Specifications

Keeprite G97CTN0601716A (Residential Furnace, PD ID 4680905) holds 1 ENERGY STAR certified SKU rated at 97.0% AFUE — #167 of 3,740 (Top 26.2%, 813 tied), +1.00% AFUE. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. Keeprite G97CTN0601716A — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 97.0% AFUE and Cohort Rank set at #167/3,740.

- **Thermal Efficiency**: 97.0% AFUE

- **Cohort Rank**: #167/3,740

- **Verified Combos**: 1 SKU

- **Sample PD ID**: 4680905

Residential Furnace Efficiency Spread across 3740 certified series (87.0 to 99.0% AFUE)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 87.0 - 88.3% AFUE | 42 | Peer range |
| 88.3 - 89.7% AFUE | 0 | Peer range |
| 89.7 - 91.0% AFUE | 0 | Peer range |
| 91.0 - 92.3% AFUE | 0 | Peer range |
| 92.3 - 93.7% AFUE | 0 | Peer range |
| 93.7 - 95.0% AFUE | 0 | Peer range |
| 95.0 - 96.3% AFUE | 2566 | Peer range |
| 96.3 - 97.7% AFUE | 1027 | This series |
| 97.7 - 99.0% AFUE | 105 | Peer range |

Keeprite G97CTN0601716A residential equipment inspection. ThermalSpec Editorial Photography

## How does Keeprite G97CTN0601716A rank across federal compliance and ENERGY STAR cohorts?

Keeprite G97CTN0601716A ranks #167 of 3,740 (tied with 812 others at 97.0% AFUE, top 26.2%, more efficient than 73.8% of certified series) for Max AFUE (+1.00% AFUE vs 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 97.0% AFUE (+17.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-08-04.

Keeprite G97CTN0601716A Cohort Metrics vs. Residential Furnace Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Max AFUE)** | #167 of 3,740 (Top 26.2%, 813 tied) | +1.00% AFUE vs 96.0% AFUE category median |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **Federal Gas Furnace Minimum** | PASS | Meets or exceeds federal 80% AFUE floor (97.0% AFUE, +17.0 pts above minimum) |
| **Condensing Secondary Heat Exchanger Tier** | CONDENSING | >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap |
| **Domestic Hot Water Integration** | SPACE HEAT ONLY | ENERGY STAR dataset flag: can_integrate_hot_water_heating |

## How much annual energy and operating cost does Keeprite G97CTN0601716A require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Keeprite G97CTN0601716A estimates reflect 1 certified SKU combination tested under PD ID 4680905.

Annual_Therms = (50 MMBtu * 10 therms/MMBtu) / (97.0% / 100)

50 MMBtu heating season at EIA US median $1.45/therm ($15.04/Mcf; range $0.74 ID to $5.05 HI)

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **Annual Natural Gas Consumption (50 MMBtu)** | 515.5 therms/yr | 6,031 lb CO2/yr (11.7 lb/therm) |
| **Estimated Annual Fuel Cost (US Median)** | $747/yr | State range: $381 (ID) to $2,603 (HI) |
| **Fuel Saved vs 80% AFUE Baseline** | 109.5 therms/yr | $159/yr saved |

80% AFUE B-Vent Chimney vs. 96% AFUE Condensing PVC Two-Pipe

Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.

## Which AHRI certified SKU combinations belong to Keeprite G97CTN0601716A?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Keeprite G97CTN0601716A (PD ID 4680905).

| G97CTN0601716A | Matched AHRI Coil | — | / 97.0% AFUE |
|---|---|---|---|

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Keeprite G97CTN0601716A, review 3 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across Keeprite G97CTN0601716A: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Keeprite G97CTN0601716A exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Keeprite G97CTN0601716A condensing combustion at 97.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal Keeprite G97CTN0601716A fit** | Single-family replacement needing documented ENERGY STAR PD ID 4680905 with matching indoor air handler. |
| **Skip Keeprite G97CTN0601716A if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable residential furnace models deliver similar efficiency?

Compare Keeprite G97CTN0601716A against Goodman GRVT960603BN and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.

### [Goodman GRVT960603BN](https://myhomeheating.org/equipment/furnaces/goodman/goodman-grvt960603bn/)

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

### [Goodman GRVT960804CN](https://myhomeheating.org/equipment/furnaces/goodman/goodman-grvt960804cn/)

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

### [Goodman GRVT961005DN](https://myhomeheating.org/equipment/furnaces/goodman/goodman-grvt961005dn/)

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

### [Grandaire WFJT060B048A](https://myhomeheating.org/equipment/furnaces/grandaire/grandaire-wfjt060b048a/)

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does Keeprite G97CTN0601716A compare with peer Residential Furnace units?

Keeprite G97CTN0601716A holds #167 of 3,740 (Top 26.2%, 813 tied) out of 3,740 verified residential furnace models (+1.00% AFUE vs 96.0% AFUE category median), spanning 1 certified SKU up to 97.0% AFUE. Closest same-cohort alternatives include Goodman GRVT960603BN.

DOE Regions

### Where is Keeprite G97CTN0601716A compliant for 2026 US installation?

Keeprite G97CTN0601716A: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does Keeprite G97CTN0601716A model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Keeprite G97CTN0601716A runs 515.5 therms/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does Keeprite G97CTN0601716A cover?

Keeprite G97CTN0601716A covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does Keeprite G97CTN0601716A handle extreme weather or cold snaps?

Keeprite G97CTN0601716A delivers steady fuel combustion independent of outdoor air temperature.

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern Keeprite G97CTN0601716A?

Keeprite G97CTN0601716A specifies sealed combustion compliance (PD ID 4680905); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 1 certified SKU in Keeprite G97CTN0601716A reach 97.0% AFUE?

Peak 97.0% AFUE represents the top tested AHRI pairing for Keeprite G97CTN0601716A (PD ID 4680905); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to Keeprite G97CTN0601716A?

Keeprite G97CTN0601716A requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Goodman GRVT960603BN.

## Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Furnaces Dataset (i97v-e8au)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Furnaces/i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [Natural Gas Prices — Annual Residential Price by State](https://www.eia.gov/dnav/ng/ng_pri_sum_a_EPG0_PRS_DMcf_a.htm) — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
4. [Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

[ All Keeprite Furnaces (139) → ](https://myhomeheating.org/equipment/furnaces/keeprite/) [ All Residential Furnaces (3,740) → ](https://myhomeheating.org/equipment/furnaces/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare Goodman GRVT960603BN (97.0% AFUE) → ](https://myhomeheating.org/equipment/furnaces/goodman/goodman-grvt960603bn/) [ Compare Goodman GRVT960804CN (97.0% AFUE) → ](https://myhomeheating.org/equipment/furnaces/goodman/goodman-grvt960804cn/) [ Keeprite G97CTN0801716A → ](https://myhomeheating.org/equipment/furnaces/keeprite/keeprite-g97ctn0801716a/) [ Keeprite G97CTN0802120A → ](https://myhomeheating.org/equipment/furnaces/keeprite/keeprite-g97ctn0802120a/) [ Keeprite G97CTN1002122A → ](https://myhomeheating.org/equipment/furnaces/keeprite/keeprite-g97ctn1002122a/)

Keeprite Quick Spec Summary

- **Cohort Rank**: #167/3,740

- **Max AFUE**: top 26.2%, 813 tied

- **Verified SKUs**: 1

- **Brand Hub**: [Keeprite](https://myhomeheating.org/equipment/furnaces/keeprite/)

- **Category Hub**: [Residential Furnace](https://myhomeheating.org/equipment/furnaces/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).
