# Heil G97CMN0802120B — Residential Furnace Specifications

Heil G97CMN0802120B (Residential Furnace, PD ID 4680678) holds 1 ENERGY STAR certified SKU rated at 97.0% AFUE — #167 of 3,740 (Top 26.2%, 813 tied), +1.00% AFUE. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. Heil G97CMN0802120B — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 97.0% AFUE and Cohort Rank set at #167/3,740.

- **Thermal Efficiency**: 97.0% AFUE

- **Cohort Rank**: #167/3,740

- **Verified Combos**: 1 SKU

- **Sample PD ID**: 4680678

Residential Furnace Efficiency Spread across 3740 certified series (87.0 to 99.0% AFUE)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 87.0 - 88.3% AFUE | 42 | Peer range |
| 88.3 - 89.7% AFUE | 0 | Peer range |
| 89.7 - 91.0% AFUE | 0 | Peer range |
| 91.0 - 92.3% AFUE | 0 | Peer range |
| 92.3 - 93.7% AFUE | 0 | Peer range |
| 93.7 - 95.0% AFUE | 0 | Peer range |
| 95.0 - 96.3% AFUE | 2566 | Peer range |
| 96.3 - 97.7% AFUE | 1027 | This series |
| 97.7 - 99.0% AFUE | 105 | Peer range |

Heil G97CMN0802120B residential equipment inspection. ThermalSpec Editorial Photography

## How does Heil G97CMN0802120B rank across federal compliance and ENERGY STAR cohorts?

Heil G97CMN0802120B ranks #167 of 3,740 (tied with 812 others at 97.0% AFUE, top 26.2%, more efficient than 73.8% of certified series) for Max AFUE (+1.00% AFUE vs 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 97.0% AFUE (+17.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-08-04.

Heil G97CMN0802120B Cohort Metrics vs. Residential Furnace Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Max AFUE)** | #167 of 3,740 (Top 26.2%, 813 tied) | +1.00% AFUE vs 96.0% AFUE category median |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **Federal Gas Furnace Minimum** | PASS | Meets or exceeds federal 80% AFUE floor (97.0% AFUE, +17.0 pts above minimum) |
| **Condensing Secondary Heat Exchanger Tier** | CONDENSING | >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap |
| **Domestic Hot Water Integration** | SPACE HEAT ONLY | ENERGY STAR dataset flag: can_integrate_hot_water_heating |

## How much annual energy and operating cost does Heil G97CMN0802120B require?

Annual cost outputs combine Heil G97CMN0802120B's 97.0% AFUE rating and EIA national tariffs across single-family runtime hours.

Annual_Therms = (50 MMBtu * 10 therms/MMBtu) / (97.0% / 100)

50 MMBtu heating season at EIA US median $1.45/therm ($15.04/Mcf; range $0.74 ID to $5.05 HI)

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **Annual Natural Gas Consumption (50 MMBtu)** | 515.5 therms/yr | 6,031 lb CO2/yr (11.7 lb/therm) |
| **Estimated Annual Fuel Cost (US Median)** | $747/yr | State range: $381 (ID) to $2,603 (HI) |
| **Fuel Saved vs 80% AFUE Baseline** | 109.5 therms/yr | $159/yr saved |

80% AFUE B-Vent Chimney vs. 96% AFUE Condensing PVC Two-Pipe

Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.

## Which AHRI certified SKU combinations belong to Heil G97CMN0802120B?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Heil G97CMN0802120B (PD ID 4680678).

| G97CMN0802120B | Matched AHRI Coil | — | / 97.0% AFUE |
|---|---|---|---|

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Heil G97CMN0802120B, review 3 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across Heil G97CMN0802120B: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Heil G97CMN0802120B exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Heil G97CMN0802120B condensing combustion at 97.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal Heil G97CMN0802120B fit** | Single-family replacement needing documented ENERGY STAR PD ID 4680678 with matching indoor air handler. |
| **Skip Heil G97CMN0802120B if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable residential furnace models deliver similar efficiency?

Compare Heil G97CMN0802120B against GUARDIAN BY JOHNSON CONTROLS RG19026A08MPS1 and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.

### [GUARDIAN BY JOHNSON CONTROLS RG19026A08MPS1](https://myhomeheating.org/equipment/furnaces/guardian-by-johnson-controls/guardian-by-johnson-controls-rg19026a08mps1/)

97.0% AFUE · Natural Gas · 1 combos

### [Goodman GD9S960403BN](https://myhomeheating.org/equipment/furnaces/goodman/goodman-gd9s960403bn/)

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

### [Goodman GD9T960403BN](https://myhomeheating.org/equipment/furnaces/goodman/goodman-gd9t960403bn/)

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

### [Goodman GD9T960603BN](https://myhomeheating.org/equipment/furnaces/goodman/goodman-gd9t960603bn/)

97.0% AFUE · Natural Gas, Propane Gas · 1 combos

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does Heil G97CMN0802120B compare with peer Residential Furnace units?

Heil G97CMN0802120B holds #167 of 3,740 (Top 26.2%, 813 tied) out of 3,740 verified residential furnace models (+1.00% AFUE vs 96.0% AFUE category median), spanning 1 certified SKU up to 97.0% AFUE. Closest same-cohort alternatives include GUARDIAN BY JOHNSON CONTROLS RG19026A08MPS1.

DOE Regions

### Where is Heil G97CMN0802120B compliant for 2026 US installation?

Heil G97CMN0802120B: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does Heil G97CMN0802120B model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Heil G97CMN0802120B runs 515.5 therms/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does Heil G97CMN0802120B cover?

Heil G97CMN0802120B covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does Heil G97CMN0802120B handle extreme weather or cold snaps?

Heil G97CMN0802120B delivers steady fuel combustion independent of outdoor air temperature.

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern Heil G97CMN0802120B?

Heil G97CMN0802120B specifies sealed combustion compliance (PD ID 4680678); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 1 certified SKU in Heil G97CMN0802120B reach 97.0% AFUE?

Peak 97.0% AFUE represents the top tested AHRI pairing for Heil G97CMN0802120B (PD ID 4680678); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to Heil G97CMN0802120B?

Heil G97CMN0802120B requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include GUARDIAN BY JOHNSON CONTROLS RG19026A08MPS1.

## Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Furnaces Dataset (i97v-e8au)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Furnaces/i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [Natural Gas Prices — Annual Residential Price by State](https://www.eia.gov/dnav/ng/ng_pri_sum_a_EPG0_PRS_DMcf_a.htm) — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
4. [Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

[ All Heil Furnaces (139) → ](https://myhomeheating.org/equipment/furnaces/heil/) [ All Residential Furnaces (3,740) → ](https://myhomeheating.org/equipment/furnaces/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare GUARDIAN BY JOHNSON CONTROLS RG19026A08MPS1 (97.0% AFUE) → ](https://myhomeheating.org/equipment/furnaces/guardian-by-johnson-controls/guardian-by-johnson-controls-rg19026a08mps1/) [ Compare Goodman GD9S960403BN (97.0% AFUE) → ](https://myhomeheating.org/equipment/furnaces/goodman/goodman-gd9s960403bn/) [ Heil G97CMN1002122B → ](https://myhomeheating.org/equipment/furnaces/heil/heil-g97cmn1002122b/) [ Heil G97CMN1202422B → ](https://myhomeheating.org/equipment/furnaces/heil/heil-g97cmn1202422b/) [ Heil G97CTN0601716A → ](https://myhomeheating.org/equipment/furnaces/heil/heil-g97ctn0601716a/)

Heil Quick Spec Summary

- **Cohort Rank**: #167/3,740

- **Max AFUE**: top 26.2%, 813 tied

- **Verified SKUs**: 1

- **Brand Hub**: [Heil](https://myhomeheating.org/equipment/furnaces/heil/)

- **Category Hub**: [Residential Furnace](https://myhomeheating.org/equipment/furnaces/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).