# Coleman Z9VT100C20SMPC1*H — Residential Furnace Specifications

Coleman Z9VT100C20SMPC1*H (Residential Furnace, PD ID 4710674) holds 1 ENERGY STAR certified SKU rated at 96.0% AFUE — #1,493 of 3,740 (804 tied at median), Equal to 96.0% AFUE category median. Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. Coleman Z9VT100C20SMPC1*H — Residential Furnace Specifications benchmarks residential systems using Thermal Efficiency set at 96.0% AFUE and Cohort Rank set at #1,493/3,740.

- **Thermal Efficiency**: 96.0% AFUE

- **Cohort Rank**: #1,493/3,740

- **Verified Combos**: 1 SKU

- **Sample PD ID**: 4710674

Residential Furnace Efficiency Spread across 3740 certified series (87.0 to 99.0% AFUE)

Inspect chart data table (9 rows)

| Efficiency Band | Series Count | Position |
|---|---|---|
| 87.0 - 88.3% AFUE | 42 | Peer range |
| 88.3 - 89.7% AFUE | 0 | Peer range |
| 89.7 - 91.0% AFUE | 0 | Peer range |
| 91.0 - 92.3% AFUE | 0 | Peer range |
| 92.3 - 93.7% AFUE | 0 | Peer range |
| 93.7 - 95.0% AFUE | 0 | Peer range |
| 95.0 - 96.3% AFUE | 2566 | This series |
| 96.3 - 97.7% AFUE | 1027 | Peer range |
| 97.7 - 99.0% AFUE | 105 | Peer range |

Coleman Z9VT100C20SMPC1*H residential equipment inspection. ThermalSpec Editorial Photography

## How does Coleman Z9VT100C20SMPC1*H rank across federal compliance and ENERGY STAR cohorts?

Coleman Z9VT100C20SMPC1*H ranks #1,493 of 3,740 (tied with 803 others at 96.0% AFUE, more efficient than 38.6% of certified series) for Max AFUE (Equal to 96.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 96.0% AFUE (+16.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2026-09-28.

Coleman Z9VT100C20SMPC1*H Cohort Metrics vs. Residential Furnace Peers

| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| **Category Rank (Max AFUE)** | #1,493 of 3,740 (804 tied at median) | Equal to 96.0% AFUE category median |

Federal Efficiency & Cold-Climate Readiness Checks

| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| **Federal Gas Furnace Minimum** | PASS | Meets or exceeds federal 80% AFUE floor (96.0% AFUE, +16.0 pts above minimum) |
| **Condensing Secondary Heat Exchanger Tier** | CONDENSING | >=90% AFUE requires Schedule 40 PVC venting and condensate drain trap |
| **Domestic Hot Water Integration** | SPACE HEAT ONLY | ENERGY STAR dataset flag: can_integrate_hot_water_heating |

## How much annual energy and operating cost does Coleman Z9VT100C20SMPC1*H require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Coleman Z9VT100C20SMPC1*H estimates reflect 1 certified SKU combination tested under PD ID 4710674.

Annual_Therms = (50 MMBtu * 10 therms/MMBtu) / (96.0% / 100)

50 MMBtu heating season at EIA US median $1.45/therm ($15.04/Mcf; range $0.74 ID to $5.05 HI)

| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| **Annual Natural Gas Consumption (50 MMBtu)** | 520.8 therms/yr | 6,093 lb CO2/yr (11.7 lb/therm) |
| **Estimated Annual Fuel Cost (US Median)** | $755/yr | State range: $385 (ID) to $2,630 (HI) |
| **Fuel Saved vs 80% AFUE Baseline** | 104.2 therms/yr | $151/yr saved |

80% AFUE B-Vent Chimney vs. 96% AFUE Condensing PVC Two-Pipe

Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.

## Which AHRI certified SKU combinations belong to Coleman Z9VT100C20SMPC1*H?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Coleman Z9VT100C20SMPC1*H (PD ID 4710674).

| Z9VT100C20SMPC1*H | Matched AHRI Coil | — | / 96.0% AFUE |
|---|---|---|---|

## What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Coleman Z9VT100C20SMPC1*H, review 3 important real-world limits and verify local licensing and permit rules directly.

- Coil pairing spread across Coleman Z9VT100C20SMPC1*H: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Coleman Z9VT100C20SMPC1*H exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Coleman Z9VT100C20SMPC1*H condensing combustion at 96.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.

| Homeowner Scenario | Recommended Verification Path |
|---|---|
| **Ideal Coleman Z9VT100C20SMPC1*H fit** | Single-family replacement needing documented ENERGY STAR PD ID 4710674 with matching indoor air handler. |
| **Skip Coleman Z9VT100C20SMPC1*H if** | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |

## Which comparable residential furnace models deliver similar efficiency?

Compare Coleman Z9VT100C20SMPC1*H against Century GDD96C070B4MP* and closely matched residential furnace units sharing similar Max AFUE output and BTU tonnage.

### [Century GDD96C070B4MP*](https://myhomeheating.org/equipment/furnaces/century/century-gdd96c070b4mp/)

96.0% AFUE · Natural Gas, Propane Gas · 1 combos

### [Century GDD96C090C4MP*](https://myhomeheating.org/equipment/furnaces/century/century-gdd96c090c4mp/)

96.0% AFUE · Natural Gas, Propane Gas · 1 combos

### [Century GDD96C110C5MP*](https://myhomeheating.org/equipment/furnaces/century/century-gdd96c110c5mp/)

96.0% AFUE · Natural Gas, Propane Gas · 1 combos

### [Century GUH96C045B3MP*](https://myhomeheating.org/equipment/furnaces/century/century-guh96c045b3mp/)

96.0% AFUE · Natural Gas, Propane Gas · 1 combos

## Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

### How does Coleman Z9VT100C20SMPC1*H compare with peer Residential Furnace units?

Coleman Z9VT100C20SMPC1*H holds #1,493 of 3,740 (804 tied at median) out of 3,740 verified residential furnace models (Equal to 96.0% AFUE category median), spanning 1 certified SKU up to 96.0% AFUE. Closest same-cohort alternatives include Century GDD96C070B4MP*.

DOE Regions

### Where is Coleman Z9VT100C20SMPC1*H compliant for 2026 US installation?

Coleman Z9VT100C20SMPC1*H: Condensing high-efficiency furnace (>=90% AFUE); exceeds federal 80% non-weatherized gas floor. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

### What annual operating cost does Coleman Z9VT100C20SMPC1*H model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Coleman Z9VT100C20SMPC1*H runs 520.8 therms/yr across standard cooling/heating hours.

BTU & Airflow

### What capacity band and airflow does Coleman Z9VT100C20SMPC1*H cover?

Coleman Z9VT100C20SMPC1*H covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

### How does Coleman Z9VT100C20SMPC1*H handle extreme weather or cold snaps?

Coleman Z9VT100C20SMPC1*H delivers steady fuel combustion independent of outdoor air temperature.

 2026 Credits & Ref

### What refrigerant class and 2026 tax credit rules govern Coleman Z9VT100C20SMPC1*H?

Coleman Z9VT100C20SMPC1*H specifies sealed combustion compliance (PD ID 4710674); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

### Do all 1 certified SKU in Coleman Z9VT100C20SMPC1*H reach 96.0% AFUE?

Peak 96.0% AFUE represents the top tested AHRI pairing for Coleman Z9VT100C20SMPC1*H (PD ID 4710674); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

### What licensing and safety checks apply to Coleman Z9VT100C20SMPC1*H?

Coleman Z9VT100C20SMPC1*H requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Century GDD96C070B4MP*.

## Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

1. [ENERGY STAR Certified Furnaces Dataset (i97v-e8au)](https://data.energystar.gov/Active-Specifications/ENERGY-STAR-Certified-Furnaces/i97v-e8au) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
2. [10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
3. [Natural Gas Prices — Annual Residential Price by State](https://www.eia.gov/dnav/ng/ng_pri_sum_a_EPG0_PRS_DMcf_a.htm) — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
4. [Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

## Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

[ All Coleman Furnaces (62) → ](https://myhomeheating.org/equipment/furnaces/coleman/) [ All Residential Furnaces (3,740) → ](https://myhomeheating.org/equipment/furnaces/) [ Check 51-State DOE SEER2 Minimums → ](https://myhomeheating.org/states/) [ Run Heat Pump vs. Gas Furnace Operating Cost → ](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/) [ Compare Century GDD96C070B4MP* (96.0% AFUE) → ](https://myhomeheating.org/equipment/furnaces/century/century-gdd96c070b4mp/) [ Compare Century GDD96C090C4MP* (96.0% AFUE) → ](https://myhomeheating.org/equipment/furnaces/century/century-gdd96c090c4mp/) [ COLEMAN BY JOHNSON CONTROLS Z9ES040A10SMPS1 → ](https://myhomeheating.org/equipment/furnaces/coleman-by-johnson-controls/coleman-by-johnson-controls-z9es040a10smps1/) [ COLEMAN BY JOHNSON CONTROLS Z9ES060A10SMPS1 → ](https://myhomeheating.org/equipment/furnaces/coleman-by-johnson-controls/coleman-by-johnson-controls-z9es060a10smps1/) [ COLEMAN BY JOHNSON CONTROLS Z9ES060B12SMPS1 → ](https://myhomeheating.org/equipment/furnaces/coleman-by-johnson-controls/coleman-by-johnson-controls-z9es060b12smps1/)

Coleman Quick Spec Summary

- **Cohort Rank**: #1,493/3,740

- **Max AFUE**: 804 tied, more efficient than 38.6% of certified series

- **Verified SKUs**: 1

- **Brand Hub**: [Coleman](https://myhomeheating.org/equipment/furnaces/coleman/)

- **Category Hub**: [Residential Furnace](https://myhomeheating.org/equipment/furnaces/)

[Compare Operating Costs →](https://myhomeheating.org/tools/heat-pump-vs-gas-furnace/)

 2026 Rebate & Refrigerant Rules at a Glance

**2026 Tax Credits & Rebates:** Federal 25C home HVAC tax credits applied to systems installed through December 31, 2025. Active 2026 savings now come from state energy rebate programs and local electric or gas utilities. **Newer Refrigerants:** Newly manufactured split ACs and heat pumps use cleaner, lower-warming refrigerants (R-454B or R-32).